This article contains a presentation of a mathematical model of the mine fire, which takes into account the consumption of oxygen in the coal combustion process. The adopted mathematical model of the mine fire, given in cylindrical coordinates, enables calculation of the temperature of the mine fire in the goaf, taking into consideration the transport and conduction of heat emitted during the coal combustion process. Furthermore, the absorption of heat by walls surrounding the goaf has also been taken into consideration.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Założono, że w ogólnym przypadku przepływy powietrza wentylacyjnego są jednowymiarowe i ustalone z wymianą energii termicznej oraz masy pary wodnej, kropelek ciekłej wody i składników roztworu suchych gazów - zwanego suchym powietrzem wentylacyjnym, którego skład chemiczny zależy od miejsca i może znacznie różnić się od składu chemicznego czystego powietrza suchego - czynnika termodynamicznego. Dlatego niniejsze obliczenie podsystemu wentylacji oparte jest na temperaturze wirtualnej suchego powietrza wentylacyjnego. Realizując je, podano wzory i związki dotyczące odpowiednio węzłów, bocznic, oczek i całego podsystemu wentylacji podczas normalnego ruchu górniczego, jak i podczas pożaru we wznoszącym się prądzie powietrza. Jako przykład przyjęto obliczenie zmodyfikowanego podsystemu wentylacji kopalni "Brzeszcze".
EN
It has been assumed that in the general case ventilating air currents are onedimensional and steady with exchange of thermal energy and mass of water vapour, liquid water droplets, and components of dry gas mixture - called dry ventilating air, which chemical composition can considerably differ from the chemical composition of pure dry air - the thermodynamic factor. Therefore, this calculation of ventilation subsystem was based upon the virtual temperature of dry ventilating air. While accomplishing this calculation, formulae and relationships were given concerning the nodes, branches and the ventilation subsystem as a whole, during normal mining operations and a fire in ascending air current. For example, the calculation of modified ventilation subsystem of "Brzeszcze" mine was assumed.
Due to the special structures and geographical environments of the main transport roadway of underground coal mines, it is difficult to deal with accidents and rescues in cases of fire and it is easy to cause casualties and structural damage of the roadway. In this study, a roadway fire model was established using FDS software on the basis of theoretical analysis. The smoke diffusion, temperature distribution, and CO concentration distribution in a fire period were simulated under four working conditions. The results showed that the time required for the smoke layer to descend to human breathing height was positively correlated with the distance between the position and the fire source. Under the most unfavorable conditions, the smoke reached human breathing height at 15.11 s and 100 m away from the fire source. After the fire broke out, the ambient temperature in the roadway rose rapidly, and the highest temperature in the area adjacent to the fire source reached 340 ℃. The farther away from the fire source, the lower the temperature, but it was still higher than the human body's optimum temperature (25 ℃) until 200 m away. The results of this study can provide a basis for the preparation of roadway fire emergency plans.
The current methods of fire diagnosis for inaccessible areas of coal mines, such as gob are not always definitive. In some cases, it is difficult to determine if incidents involving ignitions or smoldering have evolved into flaming minę fires. A more definitive test for fire could involve monitoring for the existence of radiocarbon -carbon-fourteen (14C) in carbon monoxide (CO). CO is produced by the Iow temperature oxidation of coal; however, since coal is millions of years old, this CO will not have any 14C in it. The only carbon that will have the modern amount of UC in it will be the CO2 that is in the air that is drawn into the mine by the ventilation system. In accordance with the Boudouard Equilibrium, an interchange can take place that converts CO2 to CO, but only at temperatures high enough to be associated with fire. If this interchange takes place, then CO would have 14C in it. The existence of 14C in CO could be a definitive indicator of fire in gob areas. This paper outlines the background associated with this theory and examines preliminary methods for testing for the presence of 14C.
PL
Aktualne metody diagnozowania pożarów w niedostępnych obszarach kopalni węgla, takich jak zroby, nie zawsze są rozstrzygające. W niektórych przypadkach, trudno jest określić, czy wypadki, w których nastąpił zapłon lub tlenie się spowodowały pożar w kopalni. Bardziej rozstrzygające badanie pożaru powinno obejmować monitoring obecności radiowęgla - węgla-14, (14C) w tlenku węgla (CO). Tlenek węgla jest produkowany przy niskotemperaturowym utlenianiu węgla, jednak, skoro węgiel ma miliony lat, tlenek węgla nie będzie zawierał 14C. Jedyny węgiel, który będzie zawierał C z obecnych czasów, będzie to CO2 obecny w powietrzu, które jest wprowadzane do kopalni poprzez system wentylacji. Zgodnie z równowagą Boudouarda może mieć miejsce zamiana, która przekształca CO2 w CO, ale tylko w wysokich temperaturach, które mogą towarzyszyć pożarowi. Jeśli taka zamiana ma miejsce, wtedy CO będzie zawierał 14C. Obecność 14C w CO mogłaby być rozstrzygającym wskaźnikiem pożarów w obszarach zrobów. Artykuł przedstawia w zarysie przesłanki powiązane z tą teorią i analizuje wstępne metody badania obecności 14C.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.