EN
In this study, β-galactosidase enzyme from Kluyveromyces fragilis was immobilised on a commercial polyethersulfone membrane surface, 10 kDa cut-off. An integrated process, concerning the simultaneous hydrolysis-ultrafiltration of whey lactose was studied and working conditions have been fixed at 55°C and pH 6.9, the same conditions that are used for the industrial process of protein concentration. For the immobilisation, best results were obtained using 5% (v/v) of glutaraldehyde solution and 0.03 M galactose; the total activity recovery coefficient (TARC) was 44.2%. The amount of immobilised enzyme was 12.49 mg with a total activity of 86.3 LAU at 37°C, using 5% (w/v) lactose solution in phosphate buffer (100 mM pH 6.9). The stability of the immobilised enzyme was approximately 585 fold higher in comparison with the stability of free enzyme. Multipoint covalent immobilisation improves the stability of the enzyme, thereby enhancing the decision to use the membrane as a filtering element and support for the enzyme immobilisation.
|
2002
|
tom z. 47
251-260
PL
W pracy przedstawiono wyniki badań na możliwością biodegradacji fosforanów w bioreaktorze z enzymatycznymi membranami ultrafiltracyjnymi. W procesie immobilizacji stosowano poliakrynitrylowe membrany kapilarne, modyfikowane wodzianem hydrazyny i aldehydem glutarowym. Ultrafiltracyjne membrany enzymatyczne testowano ściekami symulowanymi, zawierającym 5 mgP/dm3 (w formie K2HPO4). Podczas trwania sześciogodzinnej ultrafiltracyjnej biodegradacji z zastosowaniem wyznaczonych eksperymentalnie parametrów procesowych usunięto 53,3% fosforanów.
EN
The immobilization of enzymes on ultrafiltration capillary membranes made from polyacrylonitryle modified with hydrazine hydrate and glutaraldehyde and their application to the biodegradation of phosphates was examined. Ultrafiltration enzymatic membranes were by simulated dipotassium phosphate wastewaters which contained 5 mgP/dm3 (as K2HPO4). Carrying out ultrafiltration with assigned optimal parameters enable an 53.3% degradation after 6 hours.
|
2002
|
tom z. 47
241-249
PL
W bioreaktorze membranowym obserwuje się zwiększoną intensywność procesu biodegradacji związków organicznych. Na zjawisko ma wpływ proces separacji niektórych zanieczyszczeń na membranie, a tym samym ich kumulacja w bioreaktorze. W artykule podano stałe szybkości reakcji (k) dla trzech rodzajów mediów: modelowych ścieków zawierających substancje powierzchniowo czynne, ługi czerwone oraz mieszaniny wymienionych ścieków.
EN
The paper describes a research on the treatment of wastewater in a membrane bioreactor which showed intensification of organics biodegradation. This was influenced by separation of some contaminants on a membrane, and thus their accumulation n the bioreactor. The article presents the constant (k) for the biodegradation rate for three types of wastewater.
EN
Enzyme surface concentration and permeate stream obtained in the membrane bioreactor with a dynamically formed biocatalyst layer were determined experimentally. Correlations were formulated to calculate these values. It was found that their variability range was so big that when controlling the transmembrane pressure and turbulence of a retentate stream, the mass of used biocatalyst could be distributed in a controlled way between both reaction zones.
PL
Wyznaczono doświadczalnie wartości stężenia powierzchniowego enzymu oraz strumienia permeatu uzyskiwane przy stosowaniu membrany z dynamicznie utworzoną warstwą biokatalizatora. Opracowano korelacje do obliczania tych wartości. Stwierdzono, że przedział zmienności analizowanych wielkości jest na tyle duży, że sterując ciśnieniem transmembranowym oraz burzliwością strugi retentatu można w kontrolowany sposób rozdzielać masę użytego biokatalizatora pomiędzy obie strefy reakcji.
|
2012
|
tom nr 5
55-58
PL
W pracy opisano opracowaną procedurę jakościowoilościowego oznaczania kwasów halogenooctowych w wodzie z wykorzystaniem metody GC-MS. Procedura obejmowała trzy zasadnicze etapy tj. ekstrakcję związków z użyciem eteru tert-butylometylowego (MTBE) i ich upochadnianie do estrów metylowych oraz analizę ilościową związków metodą chromatografii GC-MS. Procedura przygotowania próby wodnej do oznaczeń była adaptacją metody US EPA 552.2. Powyższą procedurę z powodzeniem zastosowano do kontroli analitycznej usuwania kwasów halogenooctowych z wody w bioreaktorze z enzymatycznymi membranami ultrafiltracyjnymi. Określono, że istnieje możliwość efektywnego usuwania kwasów z wody w biorekatorze membranowym. W procesie immobilizacji jako nośników używano poliakrylonitrylowych ultrafiltracyjnych membran, modyfikowanych wodzianem hydrazyny i aldehydem glutarowym. Przedstawiono optymalne parametry operacyjne procesu, umożliwiające kompletne usunięcie badanych kwasów z wody.
EN
The method of qualitative-quantitative determination of haloacetic acids in water by means of GC-MS analysis is discussed in the article. The procedure comprised of three stages i.e. the extraction of compounds using methyl tert-butyl ether (MTBE), their derivatization to methyl esters and quantitative analysis by means of GC-MS method. The procedure of the preparation of feed water samples was based on US EPA 522.2 method. The analytical method was further successfully used to determine the removal of haloacetic acids from water in the membrane bioreactor. Ultrafiltration polyacrylonitrile membranes modified with hydrazine hydrate and glutaraldehyde were used as supports for enzymes immobilization. The optimal process conditions enabling the total removal of investigated compounds from water were also described.
6
Content available remote A kinetic study on drinking water denitrification using a membrane bioreactor
88%
EN
This study determines the basic parameters of Monod kinetics for microbial growth within a membrane bioreactor using the Zenon ZeeWeed 10 MBR system. The influent nitrate concentration was kept at 70 ± 2 mg L-1 NO3ˉ. During the experiments a constant concentration of activated sludge was maintained at approximately 0.76 g L-1 under anoxic conditions. Sucrose was added to the activated sludge as a carbon source. The Monod kinetic parameters were calculated by numerical interpolation, by considering experimental data. The maximum specific growth rate of the biomass was determined to be 0.31 h-1, half-saturation constant 5.4 mg L-1, and yield coefficient 0.35 mg biomass mg-1 COD. Afterwards, a dynamic simulation was performed within the calculated parameters. The dynamic concentration profiles for substrate and biomass were determined at different dilution rates within the range of 0.8 to 5 d-1.
8
88%
EN
Biological regeneration of water and organic sorbents used in the absorption of hydrophilic and hydrophobic pollutants, respectively, was studied. In both cases biodegradation takes place in a membrane bioreactor. In the case of organic sorbents regeneration of the biodegradation process is integrated with the extraction of a given pollutant to water phase. In experiments carried out in this work, the proposed systems were tested using a strain of Pseudomonas fluorescens. For hydrophilic compounds experiments were performed using alcohols (1-butanol and 2-propanol) as model substrates. Applying the mathematical model of a membrane bioreactor elaborated previously, the values of pollutant concentration were determined and positively verified in the experiments. This system of water sorbent regeneration is fully satisfying. The process of biodegradation integrated with extraction was analysed on the basis of model compounds such as benzene and toluene. The study confirmed a possibility of organic sorbent (silicone oil) regeneration. However, due to a very high partition coefficient of benzene or toluene between the organic and aqueous phases, the process could be considered only for the case of their high concentrations in the gas directed to absorption.
PL
Wraz z ekspansją przemysłu rośnie ilość i zróżnicowanie zanieczyszczeń pochodzenia antropogenicznego, które będąc w obiegu wodno-ściekowym ostatecznie przedostają się do oczyszczalni ścieków i wód powierzchniowych. W Polsce zakłady produkcyjne rocznie zużywają około 8500 mln m3 wody, odprowadzanej w postaci wód odpadowych, z których oczyszczanych jest zaledwie 13%. Poważny problem stanowią substancje biogenne, takie jak związki azotu i fosforu, których stężenia w polskich wodach powierzchniowych są znacznie większe od dopuszczalnych. Główną przyczyną złej jakości wód powierzchniowych jest gospodarka komunalna. Według danych Głównego Urzędu Statystycznego w 2007 roku w Polsce było 3041 oczyszczalni ścieków komunalnych, w tym tylko 765 z podwyższonym usuwaniem biogenów [1]. Zła jakość wód powierzchniowych oraz coraz większe jakościowe wymagania stawiane ściekom oczyszczonym wymuszają poszukiwania nowych rozwiązań technologicznych, zwiększających efektywność oczyszcza nią. W artykule przedstawiono przegląd literatury światowej w zakresie niekonwencjonalnych metod oczyszczania ścieków. Obejmuje on technologie w których zastosowano metody biologiczne, fizykochemiczne i chemiczne. Jest to przegląd prac opublikowanych głównie w ostatnich 6 latach.
|
1999
|
tom Z. 26
141-146
PL
Bioreaktor membranowy jest przykładem procesu zintegrowanego, w którym jednocześnie zachodzi reakcja biochemiczna i separacja membranowa. Membrana może być wykorzystana jako powierzchnia do wiązania biokatalizatora lub jako selektywna bariera separacyjna. Przedstawiono charakterystykę obu sposobów wykorzystania membrany. Wykazano, że zastosowanie membrany jako przegrody separacyjnej jest rozwiązaniem bardziej efektywnym procesowo, umożliwiającym kontrolę zachodzącego procesu i znajduje coraz więcej zastosowań, zwłaszcza do immobilizacji enzymów i mikroorganizmów.
EN
Membrane bioreactor is an example of hybrid process which couples biochemical reaction and membrane separation. Membrane can be used as surface for enzymes and cells bounding, entrapment whole enzymes or cells in part of reactor volume or separation barrier in reactor outlet. Two autonomous sections: reaction and separation are recommended. In this solution immobilization efficiency is 100%, reactor vessel is pressureless and membrane surface is not limited by reactor volume.
PL
W artykule podjęto się sklasyfikowania niekonwencjonalnych rozwiązań sekwencyjnych reaktorów porcjowych oraz określono, jakie efekty oczyszczania można osiągnąć w zależności od zastosowanego wariantu. Autorzy zaproponowali podział sekwencyjnych reaktorów porcjowych, uwzględniając konfigurację procesów oraz rodzaj stosowanej biomasy. W pracy przedstawiono szereg nowatorskich koncepcji reaktorów SBR. Zaprezentowano systemy CFSBR i SFBR oraz MSBR, służące do realizacji nietypowego oczyszczania ścieków. Dokonano przeglądu systemów porcjowych z biomasą granulowaną GSBR oraz z błoną biologiczną SBBR. Omówiono zarówno grupę reaktorów z biomasą wspomaganą zeolitami i węglem aktywnym, jak również grupę sekwencyjnych reaktorów membranowych SBMBR. Przedstawiona w pracy systematyka nowatorskich systemów SBR daje możliwość ich szerokiego wyboru w zależności od rodzaju i składu ścieków, wielkości układu oraz wymaganej jakości odpływu. Na podstawie analizy danych zawartych w piśmiennictwie można stwierdzić, że technologię biologicznego sekwencyjnego oczyszczania ścieków można łatwo poprawić ze względu na jej elastyczność. Modyfikacja konwencjonalnego reaktora SBR poprzez zastosowanie przedstawionych w pracy rozwiązań pozwala na modernizację istniejących już oczyszczalni, których sprawność jest za niska w stosunku do bieżących potrzeb.
EN
The studies conducted into the improvement in wastewater treatment processes efficiency and optimization in sequential systems cause a continual evolution of applied methods. Recently the classical sequencing batch reactors have themselves become the object of many modifications in which an increase in the efficiency of pollution removal from wastewater or only an intensification of individual processes like nitrification, denitrification are the aim. In this paper innovative types of sequencing batch reactor were presented. With regard to the inflow and outflow characteristic of wastewater, Continuous Flow Sequencing Batch Reactors as well as Sequencing Fed-Batch Reactors were distinguished. MSBR reactors were also described considering their application in the atypical wastewater treatment with the use of a coagulation or filtration processes. A group of sequencing reactors GSBR with an aerobic granular sludge were presented. The article contains an extensive review of Sequencing Batch Biofilm Reactors with moving bed, fixed bed and periodically submerged fixed bed. A group of reactors with zeolites and activated carbon addition to biomass as well as membrane reactors SBMBR were described. The systematics of the new SBR systems were introduced in this paper, and possibility of their wide choice depending on wastewater type and composition, sizes of system and required quality of outflow was discussed. The selection of parameters and choice of modified system will be determined by the achievement of the anticipated effects of wastewater treatment. On the basis of information contained in literature it has been possible to affirm that biological sequential wastewater treatment technology can be easily improved thanks to its elasticity. The modification of a conventional SBR using the solutions introduced in this paper allows to consider modernization of existing WWTP-s whose efficiencies are too low in relation to current needs.
first rewind previous Strona / 1 next fast forward last