Ten serwis zostanie wyłączony 2025-02-11.
Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  low frequency noise
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents the current state of knowledge concerning the sources of noise generated by wind turbines, force measurement methodology, and assessment of noise onerousness in this type of installation, on the basis of a study concerning a wind farm with five REpower MM92 wind turbines and the electric power of 2 MW and the sound power level of 104.2 dB(A) each. Particular attention was focused on the often discussed problem of presence of infrasound generated by turbines and on the requirements of the applicable reference methodologies for the measurement of wind speed to 5 m/s, while the turbine reaches its full power at speeds above 10 m/s.
EN
Low frequency noise is one of the most harmful factors occurring in human working and living environment. Low frequency noise components from 20 to 250 Hz are often the cause of employee complaints. Noise from power stations is an actual problem for large cities, including Cairo. The noise from equipments of station could be a serious problem for station and for environmental area. The development of power stations in Cairo leads to appearing a wide range of gas turbines which are strong source of noise. Two measurement techniques using C-weighted along side the A-weighted scale are explored. C-weighting is far more sensitive to detect low frequency sound. Spectrum analysis in the low frequency range is done in order to identify a significant tonal component. Field studies were supported by a questionnaire to determine whether sociological or other factors might influence the results by using annoyance rating mean value. Subjects included in the study were 153 (mean = 36.86, SD = 8.49) male employees at the three electrical power stations. The (C-A) level difference is an appropriate metric for indicating a potential low frequency noise problem. A-weighting characteristics seem to be able to predict quite accurately annoyance experienced from LFN at workplaces. The aim of the present study is to find simple and reliable method for assessing low frequency noise in occupational environment to prevent its effects on work performance for the workers. The proposed method has to be compared with European methods.
EN
In this paper, we present metrology and control methods and techniques for electromagnetically actuated microcantilevers. The electromagnetically actuated cantilevers belong to the micro electro mechanical systems (MEMS), which can be used in high resolution force and mass change investigations. In the described experiments, silicon cantilevers with an integrated Lorentz current loop were investigated. The electromagnetically actuated cantilevers were characterized using a modified optical beam deflection (OBD) system, whose architecture was optimized in order to increase its resolution. The sensitivity of the OBD system was calibrated using a reference cantilever, whose spring constant was determined through thermomechanical noise analysis registered interferometrically. The optimized and calibrated OBD system was used to observe the resonance and bidirectional static deflection of the electromagnetically deflected cantilevers. After theoretical analysis and further experiments, it was possible to obtain setup sensitivity equal to 5.28 mV/nm.
4
Content available An Adaptive System for Active Noise Reduction
75%
EN
An adaptive system for active noise reduction in an acoustic duct is presented. The system is based on a modification of a least mean square (LMS) algorithm called filtered-U with on-line error path modelling. The system was assembled and examined on a laboratory test stand in the Laboratory of Active Noise Reduction Methods of the Central Institute for Labour Protection (Warsaw, Poland). The structure of the stand, the block structure of the active noise reduction system, the basic assumption concerning the applied adaptive algorithm, and examples of measured effectiveness of the system for various kinds of noise are presented.
|
2003
|
tom nr 12
10-13
PL
Standardowe zabezpieczenia - ekrany dźwiękoizolacyjne, obudowy czy ochronniki słuchu nie są na ogół skuteczne w zakresie niskich częstotliwości. Dominującym skutkiem wpływu hałasu niskoczęstotliwościowego na organizm podczas ekspozycji zawodowej jest jego działanie uciążliwe. W artykule przedstawiono wyniki badań właściwości dźwiękoizolacyjnych elementów ścian warstwowych, stosowanych powszechnie zabezpieczeń akustycznych.
EN
Conventional noise protections are normally not effective in reducing low frequency noise. This noise is very often not only irritating but it is also critical to achieve an acceptable overall noise level. This paper presents the results of investigations of sound insulation of building elements of noise protections in a low frequency range.
6
75%
|
|
tom 32
|
nr 3
401-411
EN
A pumped storage power plant produces significant noise such that adjacent areas were deemed uninhabitable for the local population. In recent years, the population in the area has increased, and the noise levels are now causing significant distress to the local population. The company operating the power plant and a citizens’ initiative have both commissioned noise measurements. The measurements showed that the continuous pump noise was audible over many kilometers. The A-weighted sound-pressure level of 50 dBA at the next residential area underestimates the perceived noise, given the clear tonal nature in the low frequency range. Interviews of the exposed population, together with detailed “annoyance diaries” by a sample of the residents, proved their high level of annoyance. Their reported observations on distress and sleep disturbances coincide with the time course of the pumping operation. The pumping noise leads to annoyance in a large area, and to considerable nuisance in a smaller one. For the most exposed homes, long-term exposure might be considered a health hazard due to stress and disturbances in sleep quality. Therefore, the operator committed to developing a technical noise control plan. This case shows that a scientific approach within a complex environmental noise problem can foster an agreement about noise protection measures. However, this can only be successful if all involved parties participate in the process. Pilot studies are underway to test the impact of damping material layers on the pipes, the housing of the pipes, and the kind of air vessel solutions between the pumps and the pipes. Int J Occup Med Environ Health. 2019;32(3):401–11
7
Content available Infrasound and low frequency noise of a wind turbine
75%
|
|
tom Vol. 26
327--334
EN
The paper presents noise evaluation for a 2 MW wind turbine. The obtained results have been analyzed with regard to infrasound and low frequency noise generated during work of the wind turbine. The evaluation was based on standards and decrees binding in Poland. The paper presents also current literature data on the influence of the infrasound and low frequency noise on a human being. It has been concluded, that the permissible levels of infrasound for the investigated wind turbine were not exceeded.
9
Content available Choroba wibroakustyczna – przegląd piśmiennictwa
63%
PL
W artykule dokonano przeglądu piśmiennictwa dotyczącego nowej jednostki chorobowej – choroby wibroakustycznej. Choroba wibroakustyczna to ogólnoustrojowa choroba wywołana nadmierną ekspozycją na infradźwięki i hałas niskoczęstotliwościowy (0 ÷ 500 Hz). Wiąże się ona z nieprawidłowym rozrostem substancji międzykomórkowej (kolagenu i elastyny) przy nieobecności stanów za-palnych. Zgrubienia osierdzia przy nieobecności procesów zapalnych i braku zaburzeń diastolicznych to specyficzne oznaki tej choroby. U pacjentów z rozpoznaną chorobą wibroakustyczną standardowe testy diagnostyczne (ekg., eeg. i testy biochemiczne krwi) dają poprawne wyniki. Diagnostyka choroby wibroakustycznej wymaga stosowania metod umożliwiających identyfikację takich zmian strukturalnych, jak: echokardiografia, rezonans magnetyczny mózgu i badania histologiczne. Choroba wibroakustyczna była rozpoznawana głównie wśród osób eksponowanych na hałas niskoczęstoliwościowy: pracowników technicznych lotnictwa, pilotów i pozostałych członków załóg samolotów, obsługi statków, pracowników restauracji i dyskdżokejów. Przypadki tej choroby stwierdzano również wśród osób eksponowanych na hałas niskoczęstotliwościowy w miejscu zamieszkania. Nie określono jednak zależności dawka-skutek i nie przeprowadzono na dużą skalę badań epidemiologicznych. Choroba wibroakustyczna (vibroacoustic disease, VAD) jest nową jednostką chorobową wiązaną z nadmierną ekspozycją na infradźwięki (0 ÷ 20 Hz) i hałas niskoczęstotliwościowy (20 ÷ 500 Hz*). Pojęcie to wprowadzili w 1999 r. naukowcy portugalscy. Badania dotyczące skutków działania infradźwięków i hałasu niskoczęstotliwościowego są prowadzone od wielu lat w Portugalii przez zespół badaczy pod kierunkiem Nuno A. A. Castelo Branco i Mariany Alves-Pereira. Badania te rozpoczęto na początku lat 80. ubiegłego stulecia, kiedy to zauważono wśród personelu technicznego lotniczych zakła-dów produkcyjno-naprawczych Portugalskich Sił Powietrznych (Oficias Gerais de Ma-terial Aeronautico, OGMA) znacznie częstsze w stosunku do (portugalskiej) populacji generalnej występowanie padaczki (10% kontra 0,2%). Spostrzeżenie to zainicjowało badania neurofizjologiczne wśród pracowników eksponowanych na hałas niskoczęstotliwościowy (Alves-Pereira, Castelo Branco 2007). W 1983 r. zmarł pierwszy pacjent z badanej grupy pracowniczej, ale niemożliwe było wówczas przeprowadzenie sekcji zwłok. Sposobność taka pojawiła się cztery lata później, gdy inny poważnie chory pracownik OGMA wyraził życzenie przeprowadzania po jego śmierci autopsji. U 58-letniego mężczyzny, zmarłego z powodu tamponady serca wywołanej za-wałem mięśnia sercowego, z rozpoznaną wcześniej padaczką, stwierdzono zgrubienia w obrębie struktur serca (naczyń krwionośnych i osierdzia), zmiany nowotworowe mózgu i nerek oraz zwłóknienia w płucach (Castelo Branco, Alves-Pereira 2004a). Późniejsze wyniki badań mikroskopowych wykazały, że zgrubienia w obrębie struktur serca były spowodowane nienormalnym rozrostem włókien kolagenowych. Wyniki wspomnianej autopsji zainicjowały wykonywanie rutynowo badań echokardiograficznych wśród personelu technicznego OGMA. Rozpoczęto również badania histopatologiczne próbek osierdzia pobieranych przy okazji operacji chirurgicznych. Próbki takie pobrano m.in. od trzech pracowników technicznych, czterech pilotów samolotów, czterech pilotów helikopterów i jednego kierowcy ciężarówki (Leigthon 2007). Na podstawie wyników badań echokardiograficznych wykazano u wszystkich badanych techników lotniczych pogrubienie osierdzia, a u części – również zgrubienia zastawek serca (Marciniak i in. 1999). Wyniki te potwierdziły późniejsze badania z za-stosowaniem mikroskopu optycznego i elektronowego (Castelo Branco i in. 1999a; 2001; 2003a; b). Zgrubienia w obrębie struktur serca obserwowano także u zwierząt doświadczalnych (szczurów) eksponowanych na hałas niskoczęstotliwościowy (Castelo Branco i in. 2003c). Doświadczenia z udziałem zwierząt rozpoczęto w 1992 r., a jednym z powodów podjęcia tych badań był fakt, iż u wielu pacjentów stwierdzono występowanie wysięku opłucnowego o atypowej etiologii (Alves-Pereira, Castelo Branco 2007). Zgrubienia osierdzia przy braku procesów zapalnych i zaburzeń diastolicznych u osób eksponowanych na hałas niskoczęstotliwościowy są uznawane za specyficzne oznaki choroby wibroakustycznej (Holt 2000).
EN
A review of literature data concerning the vibroacoustic disease (VAD) is presented. VAD is a whole-body pathology that develops in individuals excessively exposed to infrasound and low-frequency noise (0 500 Hz). It is associated with an abnormal growth of extra-cellular ma-tricses (collagen and elastin), in the absence of an inflamantory process. Pericardial thickening with no diastolic dysfunction, and in the absence of an inflamantory process is a specific sign of this disease. Common medical diagnostic tests (ECG, EEG, blood chemistry analyses) in VAD patients present normal values. VAD diagnosis requires methods giving the possibility of identifying structural changes, such as echocardiography, brain MRI or histological tests. VAD has been mainly diagnosed in professionals exposed to low-frequency noise, such as air-craft technicians, commercial and military pilots and cabin crew, ship machinists, restaurant workers and DJs. It has also been observed in people exposed to low-frequency noise in the living environment. However, a valid dose-response has not been yet established and there are still no large-scale epidemiological studies.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.