Consider a finite population. Let qÎ(0,1) denotes the fraction of units with a given property. The problem is in interval estimation of q on the basis of a sample drawn due to the simple random sampling without replacement. In the paper three confidence intervals are compared: exact based on hypergeometric distribution and two other based on approximations to hypergeometric distribution: Binomial and Normal. It appeared that Binomial based confidence interval is too conservative while the Normal based one does not keep the prescribed confidence level.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper presents a novel adaptive hysteresis current control based on interval type2 fuzzy logic for active power filter to eliminate harmonics and compensate for reactive power. A new method to generate reference compensating current for the fundamental active current component is also proposed using the recursive discrete Fourier transform. The switching frequency of the conventional fixed hysteresis band (HB) control during the fundamental period is varied; thus causing harmonic ripple of the load current. This problem can be solved using adaptive HB control strategy. In this study, a fuzzy logic controller is used for base control because of its advantages over other adaptive HB techniques, such as mathematical simplicity, ease in adding heuristic knowledge, and robust changes in system operating conditions. An interval type2 fuzzy-adaptive HB technique is utilized for the current control to enhance the switching signals produced by the voltage source inverter. Based on the supply voltage and the slope of the reference current, this controller changes the hysteresis bandwidth. To control the DC capacitor voltage, an interval type2 fuzzy logic based controller is developed. Simulation results of the shunt active power filter with an interval type2 fuzzy adaptive HB current controller are examined and compared with the conventional controller. The results verify the effectiveness of the proposed controller in reducing total harmonic distortion from 21.03% to 2.12% and reactive power from 2616 Var to 6.28Var.
PL
Zaprezentowano nową metodę adaptacyjnego sterowanie prądem w celu eliminacji harmonicznych i kompensacji mocy biernej. Wykorzystano aktywny filtr bazujący na logice rozmytej typu 2. Stosuje się adaptacyjne histerezowe sterowanie w celu poprawy sygnału przełączania wytwarzanego przez przekształtnik napięciowy. Sterownik zmienia szerokość histerezy bazując na wartości napięcia zasilaniam i szybkości zmian pradu. Zmniejszono zawartość harm onicznych z 21% do 2 % i moc bierna z 2616 Var do 6,3 VAR.
Necessary and sufficient conditions for asymptotic stability of positive linear discrete-time systems with delays and for robust stability of interval positive systems with delays are given. First, the conditions are formulated for positive systems in general case. Next, they are simplified in two special cases: positive scalar systems with delays and positive systems with pure delay.
PL
Podano warunki konieczne i wystarczające asymptotycznej stabilności dyskretnych dodatnich układów liniowych stacjonarnych z opóźnieniami oraz odpornej stabilności przedziałowych dodatnich układów z opóźnieniami. Najpierw sformułowano warunki stabilności w przypadku ogólnym, a następnie w dwóch przypadkach szczególnych: dodatniego układu skalarnego z opóźnieniem oraz dodatniego układu z czystym opóźnieniem.