This paper deals with influence of voltage interharmonics on currents in an induction cage machine. The results of investigations are presented for 5,5 kW four-pole induction cage machine under supply with voltage containing positive-sequence and negative sequence interharmonic injections of various frequencies. The phenomena that have been known from computer simulations only, are confirmed by experimental method. It is proved in this paper that positive-sequence voltage interharmonics have result in current subharmonics flowing in machine windings. The significant dependency between the frequency of voltage interharmonics and the amplitude of current subharmonics, which has been known so far from theoretical calculations, is confirmed experimentally as well.
PL
Wychodząc ze wzoru definicyjnego mocy czynnej odbiorników energii elektrycznej, w których występują nie tylko harmoniczne prądu i napięcia ale również ich subharmoniczne i interharmoniczne, wskazano jak dobór szerokości okna pomiarowego przy uśrednianiu w czasie wpływa na dokładność pomiaru tej mocy. W wyniku badań symulacyjnych uzyskano, że dobór czasu uśredniania równy 10. krotnemu okresowi częstotliwości podstawowej jest kompromisem zapewniającym dokładność 2,5% przy założeniu, że zniekształcenia w prądzie i napięciu nie przekraczają wartości określonych normami.
EN
Starting from the formula of the active definitional power, where there are not only the harmonics of current and voltage but also their subharmonics and interharmonics, it is identified as the choice of measuring window width for averaging in time affect the accuracy of active power measurement. As a result of simulation tests, it was obtained that the selection of averaging time equal to the 10th times, the period of the fundamental frequency is a compromise that guarantee accuracy of 1%, assuming that the distortion in the current and voltage do not exceed values permissible by standards.
|
|
tom z. 63
69-70
EN
This paper presents a new modification of the least squares Prony's method for power quality analysis in terms of estimation of harmonics and interharmonics in an electric power signal.
PL
W pracy przedstawiono analizę działania toru sygnałowego flickermetru dla napięcia wejściowego składającego się z trzech składowych: o częstotliwości podstawowej oraz dwóch sub/interharmonicznych. Dla takiego napięcia wejściowego zbudowano matematyczny model flickermetru Za pomocą tego modelu wyznaczono zależność wskaźnika Pst od składowych sub/interharmonicznych o częstotliwościach pomijanych w literaturze przedmiotu. Wykazano możliwość powstawania uciążliwego migotania światła dla składowych interharmonicznych o dużych częstotliwościach. Określono wpływ faz początkowych składowych sub/interharmonicznych na wynik pomiaru Pst. W celu weryfikacji analizy porównano wyniki badań modelowych i symulacji numerycznych.
EN
An analysis of the flickermeter signal chain for the input voltage consisting of three components: the fundamental frequency fc, and the two sub/interharmonics of the frequency fm, and fn, respectively, are presented in the paper. For the purpose of model tests a simplification of the flickermeter block diagram were proposed. A mathematical model was built, consisting of a set of equations describing the dependence of Pst indicator of the amplitude of sub/interharmonics, and the initial phase of one of these components. The model equations were derived for seven areas of the fn - fm plane. The dependence of the Pst indicator on sub- and interharmonics was identified for frequencies that are skipped in the related literature. It was demonstrated that the flicker could occur for interharmonics of frequencies that are significantly higher than 100 Hz, and for subharmonics of frequencies that are less than 15 Hz. A range of frequencies of subharmonics were designated for which it is necessary to take into account the phase relations while determining the Pst indicator. The results of model tests were compared with the results of numerical simulation of the IEC flick-ermeter signal chain.
|
|
tom Vol. 2, no. 1
47--53
PL
W artykule omówiono skutki obecności interharmonicznych, tj. częstotliwości wyższych od częstotliwości podstawowej harmonicznej, niebędących jej całkowitą krotnością, w napięciu zasilającym silnik indukcyjny. Pojawienie się interharmonicznych w sieci trójfazowej jest głównie skutkiem kołysania się wartości szczytowych napięć sieciowych. W maszynach indukcyjnych powoduje to przepływ prądów o częstotliwościach interharmonicznych i subharmonicznych, generację momentów przemiennych, kołysania prędkości wirnika i zmianę wartości skutecznej prądu podstawowej harmonicznej. W artykule zbadano te zjawiska symulacyjnie, z uwzględnieniem efektu wypierania prądów w klatce wirnika. Badania przeprowadzono zarówno dla interharmonicznych o zgodnej kolejności faz, jak i o kolejności przeciwnej.
EN
The paper discusses the effects of interharmonics, i.e. frequencies higher than the fundamental frequency, not being its total multiplicity, in the voltage supplying the induction motor. The emergence of interharmonics in a three-phase grid is mainly the result of the swinging of peak mains voltages. In induction machines, this results in the occurrence of currents with interharmonic and subharmonic frequencies, the generation of alternating moments, the swinging of the rotor speed and the change in the RMS value of the current of the fundamental frequency. The paper explores these phenomena simulation, taking into account the skin effect of currents in the rotor cage. The research was carried out both for interharmonics with a positive sequence of phases as well as for the negative sequence.
6
Content available remote Diagnostyka silników asynchronicznych pierścieniowych napędu młyna cementu
63%
PL
W artykule przedstawiono wybrane zagadnienia diagnostyki napędu młyna cementu z dwoma silnikami asynchronicznymi pierścieniowymi zasilanymi z sieci przemysłowej 6 kV. Badane silniki wyposażone są w rozruszniki wodne i napędzają za pośrednictwem przekładni wieńcowej bęben młyna cementu. Na podstawie przebiegów napięciowo-prądowych zarejestrowanych w trakcie rozruchu i w stanie obciążenia wyznaczono wartości charakterystycznych wskaźników wykorzystanych w procesie diagnostyki układu napędowego. Stwierdzono zwiększoną asymetrię prądową jednego z silników. W analizie wykorzystano tzw. Sygnał "ruchomy" dokonując jego analizy częstotliwościowej w zakresie występowania inter-harmonicznych w widmie modułu wektora przestrzennego prądu |Iαβ|. Przedstawiono wyniki badań w postaci zmierzonych oraz wyliczonych charakterystyk i parametrów badanego zespołu napędowego. W końcowej części artykułu zamieszczono podsumowanie i wnioski końcowe.
EN
The paper deals with selected problems of diagnostics of a cement mill drive with two asynchronous slip-ring motors supplied from an industrial 6 kV power network. The motors are equipped with water starters and drive the mill barrel through a rim gear. The values of characteristic indices used for the system diagnostics were evaluated on the basis of voltage-current waveforms recorded during the startup and under load. It was found that one of the motors had increased current asymmetry. The analysis was carried out Rusing so called “moving” signal and its spectral analysis paying special attention to occurrence of inter-harmonics In the spectrum of absolute value |Iαβ| of the spatial current vector. The results are presented in the form of measured and evaluated characteristics and parameters of the considered drive unit. The summary and conclusions are included at the end of the paper.
7
63%
PL
W artykule rozważono aktualny problem kompensacji mocy biernej w sieciach elektrycznych z nieliniowymi szybkozmiennymi obciążeniami, takimi jak elektryczne piece łukowe, napędy walcownicze, itp. Właściwością pracy tego rodzaju obciążeń jest wprowadzanie do sieci zasilającej interharmonicznych prądu (wraz z wyższymi harmonicznymi) i stosunkowo niski współczynnik mocy. W związku z tym istnieje potrzeba oceny doboru mocy urządzeń kompensujących z uwzględnieniem losowego charakteru odkształcenia przebiegów prądu i napięcia, a w szczególności składowych interharmonicznych, których wpływ jak dotychczas nie został w pełni zbadany.
EN
The paper discusses the current problem of reactive power compensation in electric networks with non-linear fast-changing loads, such as electric arc furnaces, rolling machines, etc. Operation of this kind of loads causes that interharmonic currents (together with higher harmonics) are injected into the supply network and a relatively low power factor. Therefore, there is a need to evaluate the power selection of compensating devices, taking into account the random nature of distortion of current and voltage waveforms, in particular interharmonic components whose impact has not been fully investigated so far.
PL
W artykule omówiony został wpływ przebiegów odkształconych na dokładność pomiaru mocy w masowo instalowanych przez dystrybutorów systemu energetycznego statycznych licznikach energii elektrycznej. Przedstawiono podstawowe aspekty metrologiczne oraz niezawodnościowe dotyczące rzeczywistego pomiaru energii. Omawiana zagadnienia przedstawiono w oparciu o analizę dwóch przypadków: przebiegi odkształcone ze składową podstawową i zawartością wyższych harmonicznych oraz przebiegi odkształcone z zawartością subharmonicznych i interharmonicznych.
EN
The article discusses the influence of deformed waveforms on the accuracy of power measurement in the energy meters installed by the distributors of the power system. The basic sub-logical and reliability aspects of the real energy measure are presented. The discussed issue is presented based on the analysis of two cases: deformed waveforms with a fundamental component and higher harmonic content and distorted waveforms with subharmonic and interharmonic contents.