Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 22

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  instantaneous power
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
This paper describes the time control theory of the instantaneous power of N-phase lossy and lossless source. The instantaneous pulsating power minimization problem is discussed in detail. It was shown, that to receive the optimal power control in the case of non-stiff (lossy) source, the recursive digital filter method must be used, whereas when the source is stiff (losless) the simple FIR filter method is sufficient. Most of solved hereby problems wasn't presented before in the literature, especially those concerning the lossy supply systems.
PL
W pracy opisano procedurę sterowania w czasie rzeczywistym mocą chwilową N-fazowego źródła niesztywnego i sztywnego, zawierającego liniowy operator impedancji wewnętrznej. W szczególności rozpatrywany jest problem minimalizacji składowej pulsującej mocy chwilowej źródła. Wykazano że w przypadku źródła niesztywnego do sterowania optymalnego używa się rekursywnego filtru cyfrowego, a przypadku źródła sztywnego wystarcza użycie filtru "bez pamięci". Większość przedstawionych zagadnień nie miała rozwiązań w literaturze, dotyczy to zwłaszcza zasilania ze źródła niesztywnego.
2
Content available remote Instantaneous p-q Power Theory for Compensating Nonsinusoidal Systems
86%
EN
This paper presents a tutorial about compensation of nonsinusoidal systems based on the instantaneous active and reactive power theory or the p-q Theory. The history related to this theory is presented and then the definitions of real, imaginary and zero-sequence powers are introduced. The physical meanings of each of these powers are explained and some basic compensation examples are shown considering different active power conditioners. It is shown that this theory can be very practical for understanding problems due to nonsinusoidal voltages or currents. It is especially interesting for the design of power conditioners for three-wire or four-wire three-phase system with or without distortions in voltages and currents.
PL
Artykuł przedstawia podstawy kompensacji w układach o przebiegach niesinusoidalnych, opartej na teorii chwilowej mocy biernej p-q. Artykuł obemuje historię rozwoju teorii a następnie wprowadza definicje mocy rzeczywistej, urojonej oraz mocy kolejności zerowej. Przedstawiony jest sens fizyczny każdej z tych mocy a także przykłady kompensacji. Pokazano, że teoria ta jest bardzo praktyczna dla zrozumienia problemów powodowanych niesinusoidalnymi przebiegami prądu i napięcia. Jest szczególnie interesująca przy projektowaniu filtrów mocy dla systemów trój- i czteroprzewodowych z sinusoidalnymi i odkształconymi przebiegami prądu i napięcia.
PL
Przedmiotem pracy jest analiza skuteczności wykrywania ekscentrycznego ułożenia wirnika w synchronicznym stanie pracy wydatnobiegunowego silnika synchronicznego poprzez ocenę widma mocy chwilowej. Na specjalnie adaptowanej, obciążonej maszynie zostały wykonane badania ekscentryczności: statycznej, dynamicznej i mieszanej. W każdym przypadku były porównywane wybrane harmoniczne widma: mocy chwilowej, prądu fazowego uzwojenia stojana i prądu wzbudzenia. Wykazano różną wrażliwość przyjętych wskaźników oceny uszkodzenia dla różnych rodzajów ekscentryczności.
EN
The subject of this paper is the analysis of effectiveness of eccentric rotor’s placement detection in salient synchronous machine, while operating at synchronous speed by investigating instantaneous power spectrum. On a specially adapted machine, investigation of static, dynamic and mixed eccentricities were made during operation of the machine with load. In each case, selected spectrum harmonics of instantaneous power, phase current and field current were compared. Sensitivity of specific machine’s faults’ factors to different type of eccentricity was proved.
4
72%
|
|
tom R. 92, nr 12
296--301
PL
W artykule przedstawiono układ z samowzbudnym generatorem indukcyjnym. Został on zrealizowany na bazie silnika klatkowego i jest przeznaczony do zastosowań w małych elektrowniach wiatrowych lub wodnych. Podstawowymi zaletami takiego generatora są niezawodność, prosta konstrukcja, duża trwałość, bezobsługowość oraz niski koszt. W przedstawionym rozwiązaniu generator nie jest skojarzony z siecią zasilającą i stanowi jednostkę autonomiczną. Dla realizacji zadania stabilizacji napięcia i częstotliwości współpracuje on z przekształtnikiem AC/DC. W artykule przedstawiono wyniki badań symulacyjnych oraz eksperymentalnych układu generatora z przekształtnikiem przy sterowaniu predykcyjnym.
EN
In the paper self-excited induction generator system has been presented. It has been made on the base of cage induction motor, and it is intended for small hydroelectric and wind power plants. The basic advantages of the system are reliability, simple construction, and durability as well self-service and low cost of production. In the presented solution, generator is not connected with distribution system and represents an autonomous system. For voltage and frequency stabilization purpose its works with AC/DC converter. The paper presents the result of simulation research, as well experimental result obtained on laboratory model of generator with converters and prediction control.
5
Content available remote The features of the determination and use of instantaneous power components
72%
|
|
tom R. 96, nr 8
24--27
EN
The problem of determining the instantaneous power when it is used in the process of diagnosing nonlinear objects of electrical systems is formulated. Generalized calculation relations for instantaneous power components are obtained and presented with different methods for their determination. The results of their comparative analysis made it possible further determine the conditions of applicability of the obtained relations from the standpoint of measurement accuracy, minimizing the volume of calculations, as well as increasing the visibility and information content of the results.
PL
Analizowano problem określania mocy chwilowej przy diagnostyce obiektów nieliniowych. Przedstawiono różne metody określania składowych mocy oraz analizowano dokładność.
6
Content available Komputerowy system pomiarowy do diagnostyki łożysk
72%
|
|
tom Nr 38
15--18
PL
W artykule przedstawiono komputerowy system do diagnostyki łożysk silników indukcyjnych metodą pomiaru i analizy mocy chwilowej pobieranej przez badane maszyny. Do realizacji oprogramowania systemu pomiarowego wybrano środowisko programowania w języku graficznym LabVIEW. Opracowane oprogramowanie umożliwia analizę, archiwizację i wizualizację danych uzyskanych z pomiarów mocy chwilowej, pobieranej przez badane silniki indukcyjne, przeprowadzonych z wykorzystaniem kasety NI PXI 1033. Zadaniem opracowanej aplikacji jest również identyfikacja składowych widma mocy chwilowej, które są charakterystyczne dla szeregu typów uszkodzeń łożysk. Ponadto oprogramowanie umożliwia odczyt danych pomiarowych, które uprzednio zostały zapisane do pliku.
EN
The paper presents computer stand for bearing diagnostics of induction motors. To implement computerized measuring system the development environment of LabVIEW graphical language was used. The developed software allows to analyze, archive, and visualize data obtained from measurements of instantaneous power, absorbed by the tested induction motors, carried out with the NI PXI 1031 chassis. Purpose of the application is also developed to identify specific components for a number of types of failures. The software also allows to read the measurement data that has been previously saved to a file.
|
2017
|
tom Nr 55
11--14
EN
The paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and currentvoltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents examples of the results of analyses. On this basis, conclusions were drawn regarding the accuracy of the measurement system designed to diagnose bearings of induction motors by analysis of instantaneous power.
PL
W artykule przedstawiono zagadnienie dotyczące szacowania niepewności rozszerzonej układu do diagnostyki łożysk tocznych przy wykorzystaniu metody badawczej, opartej na pomiarze i analizie sygnału mocy chwilowej pobieranej przez silnik indukcyjny. Zastosowano metodologię GUM do oceny niepewności pomiaru i przedstawiono przykładowe wyniki wykonanych analiz. Przeprowadzona analiza metrologiczna pozwala sprecyzować, jakiej niepewności pomiaru można się spodziewać, dokonując badań diagnostycznych łożysk tocznych silników indukcyjnych w określonych warunkach, na stanowisku badawczym metodą pomiaru i analizy mocy chwilowej. Dla wartości napięcia 230 V i wartości natężenia prądu 1,97 A wynik pomiaru mocy chwilowej można przedstawić jako: p = (453,10 ± 25,33) VA. Na podstawie przeprowadzonych obliczeń można stwierdzić, iż dominujący jest tu składnik losowy typu A. Ze względu na fakt, iż wartość niepewności wynosi kilka procent wartości mierzonej prowadzone są dalsze prace, których celem będzie obniżenie wartości niepewności poprzez modyfikację układu pomiarowego.
|
|
tom nr 78
23--42
PL
W artykule przedstawiono sterowanie samowzbudnym generatorem indukcyjnym w warunkach obciążenia niesymetrycznego oraz nieliniowego. W układzie modelowym niesymetryczne obciążenie generatora stanowiły liniowe elementy typu LR. Krańcowym przypadkiem obciążenia niesymetrycznego było obciążenie jednofazowe, natomiast nieliniowe obciążenie generatora było modelowane za pomocą jednofazowych prostowników diodowych z filtrami wyjściowymi typu L oraz LC i obciążeniem rezystancyjnym. Badano również układy z obciążeniem nieliniowym w postaci trójfazowego prostownika diodowego z filtrem wyjściowym typu L. Ponieważ dopuszczalne było obciążenie fazowe, to samowzbudny generator indukcyjny był typu czteroprzewodowego. Niesymetryczne oraz nieliniowe obciążenie trójfazowego generatora wywołuje niesymetrię napięć i prądów. W przewodzie zerowym generatora pojawia się prąd, a w prądach fazowych wyższe harmoniczne. W celu likwidacji powyższych zjawisk w układzie sterowania generatorem zastosowano trójfazowy – czterogałęziowy przekształtnik sieciowy. Strategia sterowania przekształtnikiem bazuje na detekcji podstawowej harmonicznej napięcia i wykorzystaniu pojęcia mocy chwilowych do eliminacji niesymetrii obciążenia, odkształcenia prądów fazowych i eliminacji prądu w przewodzie zerowym generatora. W artykule przedstawiono wyniki badań symulacyjnych generatora z proponowanym układem sterowania. Uzyskane wyniki wskazują, że zaproponowany układ sterowania pracuje poprawnie w szerokim zakresie i przy dużej dysproporcji obciążenia poszczególnych faz zarówno przy obciążeniu liniowym, jak i nieliniowym. Kompensacja prądu w przewodzie zerowym oraz kompensacja niesymetrii obciążenia i wyższych harmonicznych uzasadnia zastosowanie w układzie sterowania generatora czterogałęziowego przekształtnika sieciowego.
EN
The article describes control of the self-excited inductive generator at unbalanced and non-linear load conditions. This type of load causes unbalanced, current flow in neutral wire and currents harmonic. To eliminate above described effects, a three-phase four-branched grid converter has been used in the control system of the generator. Control strategy of the converter is based on the detection of voltage fundamental frequency and the usage of instantaneous power theory to symmetrize the load and eliminate the current in the neutral wire of the generator. The article presents results of simulated generator with proposed control system. The results indicate that this control system works correctly with established load conditions.
|
|
tom Nr 51
45--48
PL
W artykule przedstawiono zagadnienie dotyczące szacowania niepewności rozszerzonej w układzie do diagnostyki łożysk tocznych przy wykorzystaniu metody badawczej, opartej na pomiarze i analizie sygnału mocy chwilowej pobieranej przez silnik indukcyjny. Zaprezentowano metodologię oceny niepewności pomiarowej i przedstawiono przykładowe wyniki wykonanych analiz. Na tej podstawie sformułowano wnioski dotyczące możliwości wykorzystania układu przeznaczonego do diagnostyki łożysk w silnikach indukcyjnych z określoną dokładnością.
EN
The paper presents the issue concerning the estimation of expanded uncertainty of the rolling bearings diagnostic system using the test method based on the measurement and analysis of signals instantaneous power consumed by the induction motor. The methodology for assessing the measurement uncertainty has been presented and examples of the analysis results have been given. The conducted metrological analysis allows to specify which measurement uncertainty can be expected while making a diagnostic of induction motors rolling bearings in specified conditions on a test bench with the use of a measurement and analysis method of instantaneous power. The uncertainty of measurement of instantaneous power the motor with a damaged bearing for a voltage of 230 V and a current of 2.19 A can be represented as: p = (503.70 ± 32.56) VA. On the basis the conducted calculations it can be concluded that there is a dominant component of random concerning uncertainty Type A. Due to the fact that the value of uncertainty is of a few percent of the measured value, according to the author, the estimated measurement uncertainty does not prevent the use of this system for bearings diagnostics.
|
2013
|
tom nr 10
34--38
PL
Współcześnie większość budynków użyteczności publicznej wyposażona jest w instalację wentylacji mechanicznej, która pochłania dużą część energii zużywanej przez budynek. Jednym z podstawowych procesów uzdatniania powietrza w tych instalacjach jest jego ogrzewanie. Nie można mówić o prawidłowo funkcjonującej centrali wentylacyjnej bez dobrze działającej nagrzewnicy. Dążenie do wykorzystywania wysokosprawnych urządzeń o małej energochłonności, jak również urządzeń do odzysku ciepła jest jak najbardziej pożądane, jednak często zdarza się, że praca istniejącej instalacji odbiega od założeń projektowych, powodując zwiększenie zużycia energii lub niedotrzymanie warunków cieplno-wilgotnościowych obsługiwanych pomieszczeń. Rozbieżności mogą dotyczyć doboru poszczególnych urządzeń w stosunku do założeń projektowych, jak również wadliwej pracy samych urządzeń spowodowanej np. mechanicznymi uszkodzeniami bądź zabrudzeniami. Silne naciski na oszczędzanie energii we wszystkich dziedzinach funkcjonowania budynku spowodowały, że działanie nagrzewnicy powietrza w układach wentylacji mechanicznej jest poddawane częstej ocenie, na którą składa się inspekcja oraz pomiary diagnostyczne. Artykuł podaje prosty sposób postępowania w trakcie okresowej kontroli mającej na celu sprawdzenie poprawności działania nagrzewnicy wodnej. Przedstawiono zarówno istotę inspekcji instalacji oraz poszczególne kroki prostych pomiarów diagnostycznych.
EN
Today, most of the public utility buildings equipped with mechanical ventilation, which absorbs many of energy. Heating the air is one of the basic air conditioning processes. There can be no properly functioning ventilation unit without a functioning heater. The aim to use high-performance devices with low energy consumption, as well as heat recovery equipment much-desired, but it often happens that the work of the existing system differs from project assumptions, resulting in increased energy consumption, or failure to thermal conditions in serviced rooms Strong pressure on energy saving in all areas of the operation of the building meant that the operation of the air heater in mechanical ventilation systems are subject to frequent evaluation, which consists of inspection and diagnostic measurements of the ventilation system. The paper presents a simple procedure of periodic inspection to verify proper operation of water heaters. There is description of inspections and steps of simple diagnostics measurements.
EN
The analysis of energy transfer in the circuits is based on the instantaneous power p(t), which is the product of the two waveforms u(t), i(t). An interesting thing is the search for mutual relations between these two waveforms. In the paper the authors made an attempt to describe power states in electrical circuits with periodic waveforms with the help of the correlation of the two functions. In mathematics correlation is the measure of similarity or mutual dependence between the two functions. Electrical energy is a simultaneous and mutual cooperation of voltage and current waveforms - therefore, the authors defined and examined the correlation function of these waveforms. On the basis of the defined correlation function between the voltage and the current, the authors introduced two new powers: the sine power function and the cosine power function.
PL
Analiza transferu energii w obwodach bazuje na mocy chwilowej p(t) będącej iloczynem dwóch przebiegów u(t) oraz i(t). Interesujące staje się poszukiwanie wzajemnej relacji miedzy tymi dwoma przebiegami. W artykule autorzy podjęli próbę opisu stanów energetycznych w obwodach elektrycznych z przebiegami okresowymi za pomocą korelacji dwóch funkcji. W matematyce korelacja jest miarą podobieństwa lub wzajemnej zależności między dwiema funkcjami. Ponieważ energia elektryczna jest jednoczesnym i wzajemnym współdziałaniem przebiegów napięcia i prądu, dlatego też autorzy zdefiniowali oraz badali funkcję korelacji tychże przebiegów. Na podstawie zdefiniowanej funkcji korelacji między napięciem i prądem, autorzy wprowadzają dwie nowe funkcje mocy, sinusową funkcję mocy oraz kosinusową funkcję mocy.
EN
Numerous publications point out that each of the so far presented proposals how to describe power states has some defects, they all lack the physical interpretation or the universal character. Yet, the application of a given power theory to analyze the electric circuit was not preceded by the proof of the rightness of such a procedure in relation to the character of this circuit. The authors of this paper seek the answer to the question whether a given power theory can be successfully applied in the analysis of both linear and non-linear circuits.
PL
Liczne publikacje naukowe wskazują na defekty, brak interpretacji fizycznej lub brak uniwersalnego charakteru każdej z dotychczas przedstawionej propozycji opisów stanów energetycznych. Wszystkie teorie zgodne były jedynie co do mocy chwilowej p(t) oraz mocy czynnej P, zdefiniowanej jako wartość średnia całookresowa z mocy chwilowej. Jednakże zastosowanie danej teorii do analizy obwodu elektrycznego nie było poprzedzone dowodem na słuszność takiego postępowania w zależności od charakteru obwodu. Autorzy poszukują odpowiedzi na pytanie czy dana teoria może być z powodzeniem stosowana w analizie zarówno obwodów liniowych jak i nieliniowych.
PL
W artykule przedstawiono zagadnienie dotyczące wykorzystania przyrządu wirtualnego do szacowania niepewności pomiaru mocy chwilowej. Analiza dotyczy układu do diagnostyki łożysk tocznych, składającego się z przetworników: napięcia oraz prąd-napięcie, który wykorzystano do badań diagnostycznych łożysk silników indukcyjnych metodą, opartą na pomiarze i analizie sygnałów napięcia i prądu pobieranych przez maszynę. Zaprezentowano opracowany do celów szacowania niepewności pomiaru mocy chwilowej przyrząd wirtualny, który do wyznaczania niepewności metodą Typu A wykorzystuje jakobiany macierzy, natomiast do obliczenia niepewności metodą Typu B używa danych, dotyczących dokładności karty akwizycji danych i przetworników. Dokonano także sprawdzenia poprawności działania przyrządu wirtualnego, przedstawiono przykładowe wyniki analiz i porównano je z rezultatami obliczeń wykonanymi przy wykorzystaniu arkusza kalkulacyjnego MS Excel.
EN
The paper presents the issue of the use of a virtual device to estimate the uncertainty of a system for rolling bearing diagnostics using a research method based on measuring and analysing the instantaneous power signal consumed by an induction motor. The virtual instrument developed for the purpose of estimating the uncertainty of instantaneous power measurement has been used to estimate the uncertainty of Type A instantaneous power measurement using Jakobian matrix, while to calculate the uncertainty of Type B uses the data on the accuracy of instruments used, given by their manufacturers. For comparison, calculations of uncertainty of instantaneous power measurement were also made using the MS Excel spreadsheet. In both cases, the obtained results were identical. In the case under consideration, the result of instantaneous power measurement, with a voltage of 236.54 V and a current value of 3.03 A, can be represented as: p = (716.72 ± 34.44) VA. The developed virtual instrument can be used to estimate the uncertainty of measurement of other physical quantities, e.g. temperature or pressure.
EN
The method of nonlinear electric circuit’s analysis using the method of forming and solving instantaneous power orthogonal components balance equations is developed. The advantages of the developed method are that it allows to analyze the mechanism of formation of instantaneous power orthogonal components and to evaluate the influence of parameters on the researched electric circuit operation. Developed method allows to increase the efficiency of the nonlinear electric circuits analysis theory. It was shown that the proposed method avoids complex intermediate analytical transformations due to the use of the developed automated method of forming instantaneous constituents based on the discrete convolution algorithm.
XX
W artykule przedstawiono wyniki opracowanej metody analizy nieliniowego obwodu elektrycznego za pomocą metody formowania i rozwiązywania równań równowagi ortogonalnej składowej mocy. Zalety opracowanej metody polegają na tym, że pozwala ona analizować mechanizm powstawania składowych ortogonalnych mocy chwilowej i oceniać wpływ parametrów na działanie obwodu elektrycznego. Opracowana metoda pozwala zwiększyć efektywność teorii analizy nieliniowych obwodów elektrycznych. Wykazano, że proponowana metoda pozwala uniknąć skomplikowanych pośrednich przekształceń analitycznych dzięki zastosowaniu opracowanej zautomatyzowanej metody formowania natychmiastowych składników w oparciu o algorytm dyskretnego splotu.
EN
The paper describes a way for providing induction motor diagnostic in case of motor fed using frequency converter, when additional distortions caused by pulse-width modulation could affect the diagnostic result. It is proposed to use preliminary clarification of current and voltage signals, aimed to exclude from consideration harmonics caused by pulse-width modulation, with further re-computation of power spectra using discrete convolution algorithm.
PL
Artykuł opisuje metodę diagnostyki silnika indukcyjnego zasilanego przetwornikiem częstotliwości w przypadku występowania zakłóceń spowodowanych modulacją szerokości impulsu. Zaproponowano wstępne oczyszczanie sygnałów prądowych i napięciowych mające na celu wyłączenie z rozważań harmonicznych generowanych modulacją szerokością impulsu. Prowadzi to do ponownego obliczania spektrum mocy z wykorzystaniem dyskretnych algorytmów konwolucyjnych.
|
2018
|
tom R. 94, nr 11
159--165
PL
W artykule przedstawiono układ generatora indukcyjnego współpracującego z siecią elektroenergetyczną z wykorzystaniem przekształtnika AC/DC/AC. W przekształtniku, zarówno od strony generatora jak i sieci, zastosowano falowniki trójpoziomowe. Jednocześnie maksymalnie uproszczono modulatory. Sterowanie generatora oparto na pośredniej orientacji wektora pola IFOC z wykorzystaniem algorytmu MPPT. W obwodzie pośredniczącym zastosowano układ równoważenia napięcia. Synchronizację sterowania zapewnia pętla PLL z układem CDSC.
EN
The article presents of an induction generator cooperating with a power grid using an AC/DC/AC converter. In the converter, both on the generator and network side, three-level inverters were used. Simultaneously, modulators have been simplified to a minimum. The generator's control was based on the indirect orientation of the field vector using the MPPT algorithm. In the intermediate circuit a voltage balancing system was used. Control synchronization is provided by the PLL-CDSC system.
PL
W artykule przedstawiono sterowanie samowzbudnym generatorem indukcyjnym w warunkach niesymetrycznego i nieliniowego obciążenia. Tego typu obciążenie wywołuje niesymetrię, wyższe harmoniczne prądów generatora, oraz prąd w przewodzie zerowym. W celu likwidacji powyższych zjawisk, w układzie sterowania generatorem zastosowano trójfazowy - czterogałęziowy przekształtnik. Strategia sterowania przekształtnikiem bazuje na detekcji podstawowej harmonicznej napięcia i wykorzystaniu pojęcia mocy chwilowej.
EN
The article describes control of the self-excited inductive generator at unbalanced and non-linear load conditions. This type of load causes unbalanced, currents harmonic and current flow in the neutral. To eliminate above effects, a three-phase four-leg grid converter has been used in the control system of the generator. Control strategy of the converter is based on the detection of voltage fundamental frequency and the usage of instantaneous power theory.
|
|
tom R. 56, nr 5
464-470
PL
W artykule przedstawiono sposób wyznaczania składowych mocy według podejścia zaproponowanego przez Hashada i Hartmana. Dla porównania wyników uzyskanych tym sposobem, zastosowano definicje mocy zalecane przez standard IEEE 1459-2000. Badania były wykonywane pod kątem wykorzystania cyfrowego przetwarzania sygnałów do określania parametrów mocy. Przeprowadzono je dla przebiegów sinusoidalnych i okresowych niesinusoidalnych. Zastosowano wyznaczanie mocy zgodne ze standardem IEEE: na podstawie wartości chwilowych, według Budeanu oraz Depenbrocka. Do wyznaczania mocy według podejścia Hashada i Hartmana napisany został program w języku C++ "Funkcje" oraz arkusz obliczeniowy w programie Excel. W pracy przedstawiono wyniki badań symulacyjnych.
EN
A comparison of determination methods of power parameters by Hashad and Hartman way and by recommendation of IEEE 1459?2000 standard, in order to make the use digital signal proc-essing for describing the power components there are presented in the paper. Hashad and Hartman power functions properties are described in Chapter 2. In the paper a determination of power according to IEEE standard was applied: on the basis of instantane-ous values, by Budeanu way and by Depenbrock way. The formulas are described in Chapter 3. For calculation of power by Hashad and Hartman way program in C++ language called "Funkcje" and spread-sheet of Excel program were created. Thanks to the written software the comparison and evaluation of Hashad and Hartman way with actually valid IEEE 1459-2000 standard methods were carried out. The comparison and evaluation with use of sinusoidal and periodic non-sinusoidal waveforms were made up. The examples of voltage and current simulation waveforms are shown on Figures 2, 4 and on Figures 3, 5 appropriate to them functions of power waveforms. The most important results of re-search and intermediate conclusions are presented in Chapter 5, in Tables 1 to 6 and on Figures 6 to 8. The main conclusions and future direction of the work are pointed out in Chapter 6.
19
58%
PL
W artykule przedstawiono sterowanie samowzbudnym generatorem indukcyjnym w warunkach współpracy z siecią energetyczną. Pozwoliło to rozszerzyć zakres zastosowania układu. Zaproponowany układ charakteryzuje się bardzo dużą elastycznością zasilania odbiorników łącznie z możliwością odsprzedaży wytworzonej energii do sieci. Kierunek przepływu energii do sieci może w zaproponowanym układzie zostać odwrócony. Stan taki występuje w przypadku niedoboru energii wytwarzanej przez generator SEIG (mała siła wiatru, niski stan wody, duże zapotrzebowanie na energię). Możliwość zmiany kierunku przepływu energii gwarantuje przekształtnik dwustronny AC/DC/AC zastosowany w proponowanym rozwiązaniu. Przekształtnik dwustronny jest sprzężony z siecią poprzez filtr LCL. Rozwiązanie to zapewnia sinusoidalny kształt prądu zarówno w przypadku przepływu energii do sieci, jak i z sieci. W przypadku pełnego przetwarzania energii generatora bez współpracy z siecią układ pracuje w trybie autonomicznym lub bezprzerwowego zasilania.
EN
The article presents the control of the self-excited induction generator in terms of cooperation with the mains. This made it possible to extend the scope of the system. The proposed system is characterized by very high flexibility of powering receivers as well as the possibility of reselling the produced energy to the grid. The direction of flow of energy to the proposed arrangement can be reversed. This condition occurs in case of shortage of energy produced by the generator SEIG (small wind strength, low water level, high energy requirements). The ability to change the direction of energy flow is ensured by a bilateral converter AC/DC/AC used in the proposed solution. The grid inverter is coupled to the network through an LCL filter. This solution provides a sinusoidal current flow in both directions: power supply and the grid. In the case of complete processing of the power of generator without the cooperation with the grid, the system operates in standalone mode or uninterruptible power supply mode.
EN
A power approach to estimation of electromechanical complexes controllability using instantaneous power method has been offered. It has been determined that power controllability characterizes the quality of energy conversion processes in the system, reflects manifestation of nonlinear properties of the object. A mathematical procedure for determination of power losses for the whole power channel of electromechanical complex power conversion has been developed. It has been shown that formation of balance equations of separate instantaneous power components underlies the estimation of electromechanical complexes power controllability.
PL
Zaproponowano sposób oszacowania sterowności zespołów elektromechanicznych przy użyciu metody mocy chwilowej. Zostało określone, że sterowność mocy charakteryzuje jakość energii w procesie jej przekształcania oraz przedstawia własności nieliniowe obiektu. Rozwinięto procedurę matematyczną dla określenia start mocy w całym kanale mocy układów elektromechanicznych. Pokazano, że utworzenie równań równowagi dla składników mocy chwilowej leźy u podłoża oszacowania sterowności układów elektromechanicznych.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.