Ten serwis zostanie wyłączony 2025-02-11.
Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 35

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  household sewage
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Seven small wastewater treatment plants were chosen for evaluation. These WWTPs work on the principle of anaerobic pre-treatment and aerobic post-treatment and were made with the cooperation of Slovak Technical University with ASIO-SK s.r.o. Bytča and ASIO s.r.o. Brno. Wastewater treatment plants are made for 5-600 PE. When operated at suitable conditions, the results match the directive water discharge from small wastewater treatment plants in the Slovak Republic.
EN
In the paper we present the evaluation of the effectiveness of the removal of biogenic compounds and indicator bacteria from domestic sewage in a vertical flow filter with a variety of fillings. The research was carried out on expanded clay, zeolite, calcined siliceous limestone, and crushed PET flakes. Based on the study of raw and treated wastewater, the effectiveness of removal of ammonium nitrogen, orthophosphates, Escherichia coli, and coliform bacteria was determined according to the selectivity, porosity and grain size of the fill. In the case of removing biogenic compounds, the most effective fillers were found to be of natural porous selective materials, such as zeolite and calcined siliceous limestone. They produced a very high removal rate of ammonium and orthophosphate, amounting to 75.34%, and over 79%, respectively. It has been demonstrated that the filter that was filled with natural porous material of fine particle size (the zeolite) was the most suitable for the removal of indicator bacteria. A very high degree of the Escherichia coli (99.98%) and coliform bacteria (99.94%) reduction was obtained.
PL
W artykule przedstawiono ocenę skuteczności usuwania związków biogennych oraz bakterii wskaźnikowych ze ścieków bytowych w filtrach pionowych o zróżnicowanym wypełnieniu. Analizie poddano keramzyt, zeolit, wyprażaną opokę oraz rozdrobnione płatki PET. W oparciu o badania ścieków surowych i oczyszczonych określono efektywność usuwania azotu amonowego, ortofosforanów oraz bakterii Escherichia coli i bakterii grupy coli w zależności od selektywności, porowatości oraz wielkości uziarnienia wypełnienia. W przypadku usuwania związków biogennych najskuteczniejszym wypełnieniem okazały się naturalne materiały selektywne porowate, tj. zeolit i wyprażana opoka. Stwierdzono na nich bardzo wysoki stopień usunięcia odpowiednio jonów amonowych na poziomie 75,34% oraz ortofosforanowych powyżej 79%. Wykazano, że filtr zasypany naturalnym materiałem porowatym o drobnym uziarnieniu okazał się najbardziej odpowiedni do usunięcia bakterii wskaźnikowych. Stopień eliminacji bakterii grupy coli wyniósł 99,94%, a bakterii Escherichia coli 99,98%.
PL
W artykule przedstawiono wyniki rocznego monitoringu efektywności ośmiu gruntowo-roślinnych oczyszczalni ścieków wybudowanych w ramach projektu Centrum Zielonych Technologii, realizowanego przez Podlaską Stację Przyrodniczą NAREW. Celem badań było sprawdzenie, czy obok wysokiej efektywności ekonomicznej i wysokiego poziomu satysfakcji użytkowników, zapewniają one również wymaganą efektywność oczyszczania.
EN
The paper presents results of the annual research project on effectiveness of eight vertical flow constructed wetland built within the framework of the Centrum Zielonych Technologii project, which was conducted by Podlaska Stacja Przyrodnicza NAREW. The aim of the research was to prove whether or not the constructed wetlands provide required ecological effectiveness apart from their high economical efficiency as well as high level of users' satisfaction.
EN
Artificial aeration was added to an integrated vertical-flow constructed wetland (called aerated IVCW hereafter) for improving water purification performance. The results showed that both oxygen levels and aerobic zones were increased in the wetland substrates. The electric potential (Eh) profiling demonstrated that artificial aeration maintained the pattern of sequential oxic-anoxic-oxic redox zones within the aerated IVCW chambers in winter, while only two oxic-anoxic zones were present inside the non-aerated IVCW in the cold seasons. The nitrification/denitrification processes and organic matter decomposition were enhanced by artificial aeration since the removal efficiency of NH₄⁺-N and BOD₅ were significantly improved in all seasons, particularly in winter. It seemed that artificial aeration could compensate for the absence of plant-mediated oxygen supply, though the low temperatures and plant dieback still affected the removal efficiency of COD and TN in the winter. Eight hours of artificial aeration per day was sufficient to eliminate the significant accumulation of NO₃⁻-N previously observed in the effluent from continuously aerated subsurface-flow constructed wetlands. These results suggest that the aerated IVCW could treat domestic sewage more efficiently, especially in winter.
EN
Water is a resource of increasing scarcity due to continual expansion of production. Many authors have focused on wastewater recycling for industry and municipal wastewater plants, but wastewater recycling at the community level still lacks a full discussion. This paper focuses on the issue involving only household wastewater recycling which is separated into graywater and blackwater by households. We propose a theoretical framework for analyzing the recycling of household graywater through a simple process that is installed in communities, as well as the re-use of reclaimed water for a variety of applications either in or outside the community. There are at present no statutory regulations to govern the re-use of reclaimed water. Hence, piping and ducting systems for blackwater and graywater in households are not distinguished and a public ducting system for graywater is still not available in the market. In order to shed light on the dynamics of the household wastewater recycling system, we develop an implementation plan involving governmental policy, a community’s construction of treatment plants, a household’s commitment to recycling, control and checking up, and the education system in order to arouse the public to participate in this system.
9
72%
PL
Celem artykułu było określenie skuteczności zmniejszenia zanieczyszczeń w oczyszczalni ścieków w miejscowości Proszówki (gmina Bochnia, województwo małopolskie). Oczyszczalnia ta została zaprojektowana na średni przepływ ścieków 250 m3 × d–1, przy czym 200 m3 × d–1 stanowią ścieki bytowe, a 50 m3 × d–1 ścieki z zakładu masarskiego. Analizie fizykochemicznej poddano trzy wskaźniki zanieczyszczeń z grupy podstawowej: BZT5, ChZTCr oraz zawiesinę ogólną. Badano ścieki surowe dopływające do oczyszczalni i oczyszczone na odpływie do odbiornika. Łącznie analizie poddano 24 próbki ścieków. Na podstawie przeprowadzonych badań stwierdzono bardzo dobrą skuteczność zmniejszenia zanieczyszczeń: BZT5 – 92,8%, ChZTCr – 94,5%, zawiesina ogólna – 95,9%. Nie stwierdzono przekroczeń wartości badanych wskaźników w ściekach oczyszczonych w stosunku do wartości dopuszczalnych, przedstawionych w pozwoleniu wodnoprawnym.
EN
The objective of the paper was to determine the effectiveness of pollutants’ reduction in the sewage treatment plant in Proszówki and to present number of transgressions of the index values in the treated sewage in comparison to the admissible value. The treatment plant is located in Proszówki in Bochmia commune in Lesser Poland voivodeship. It was designed for the average sewage flow of 250 m3 × d–1, wherein 200 m3 × d–1 is household sewage and 50 m3 × d–1 is sewage from a butchery. Three indicators of the primary group: BOD5, CODCr and total suspended solids were analysed physicochemically. Raw sewage that flow into the treatment plant and treated sewage in the outflow to the collector were tested. A total of 24 sewage samples were analysed. Based on the carried out research high effectiveness of pollutants reduction was found: BOD5 – 92,8%, CODCr – 94,5%, total suspended solids – 95,9%. No transgressions of values of the tested indexes in the treated sewage in comparison to the admissible values in the water–law permission were found.
EN
The paper presents results of two year field and laboratory investigations of a denitrifying system below leach lines. More than two days retention time was provided by siphoning of the denitrifying trough located 35 and 60 cm under the leach lines. Due to clogging and capillary suction in medium sand the seepage flow through the denitrifying troughs was limited to less than 10 % of the sewage inflow. Average efficiency of the total nitrogen removal was equal to 55 % after 3-4 days of travel time within the soil. To force wastewater to pass through the anaerobic bed within the trough two lateral vertical impermeable membranes are recommended.
EN
The possibility of an electromagnetic field (EMF) influencing the intensification of phosphorus (P) and organic compound (COD) removal from domestic wastes was investigated. The impact of an EMF as the only factor or as an intensifying element in steel packing systems that limits pollutant concentrations in the treated wastes was analysed. The research was conducted in three stages in a static system at the laboratory scale. A significant dependence between the kind of system used, time of detention, flux intensity electromagnetic field and the effectiveness of the pollutants limitation were observed. Most efficient was the system that combined simultaneously steel filling and under electromagnetic flux intensity O = 100.0 µWb and O= 135.0 µWb. In the case of 48 hours the reaction time let to remove from the system the whole phosphorus amount as P-PO4 for treated sewage. These technological variants seem to be the most effective as for Ptot and COD.
EN
The studies conducted in the three-stage waste-water treatment plant for agricultural and domestic sewage in Łężany showed that the greatest reduction of indicator microorganisms, between 70% and 100%, occured in biological ponds. Biofilters (rotating biological disks and multicage rotating contactor) reduced the occurence of the studied microorganisms by 40—70%, mechanical purification by 40—50%. The purified sewage flowing to Legińskie Lake possessed the features of unpolluted or only slightly polluted water.
PL
Celem badań było określenie, w jakim zakresie występujące w okresie wiosennym roztopy śniegu wpływają na podwyższenie dopływu wód przypadkowych do oczyszczalni ścieków w systemach kanalizacji rozdzielczej. Badania prowadzono od 1stycznia 2010 do 30 marca 2010 roku w czterech wybranych systemach kanalizacyjnych zlokalizowanych na terenie województwa małopolskiego. W ramach badań prowadzono pomiary godzinowej temperatury powietrza atmosferycznego oraz dobowe pomiary przepływających ścieków.    Intensywne roztopy śniegu w roku 2010 rozpoczęły się 19 lutego, a zakończyły 4 marca. Średni udział wód przypadkowych w dopływie ścieków do poszczególnych oczyszczalni w okresie roztopów wynosił od 36,6 do 58,1%. Największe dopływy wód przypadkowych wystąpiły w dniu 1 marca (średnia dobowa temperatura powietrza 6,6°C), a ich udziały w stosunku do przepływu średniego dobowego przy pogodzie bezdeszczowej wyniosły odpowiednio: 56,8% w kanalizacji A, 74,3% w kanalizacji B, 54,7% w kanalizacji C i 76,5% w kanalizacji D. Przedstawione liczby wskazują, że we wszystkich analizowanych systemach kanalizacyjnych ponad 50% przepływu dobowego stanowiły wody przypadkowe wywołane roztopami śniegu. W okresie największych roztopów śniegu, tj. od 19 lutego do 3 marca 2010 roku, do badanych systemów kanalizacyjnych dopłynęły wody przypadkowe w ilości: 3641 m3 w kanalizacji A, 6926 m3 w kanalizacji B, 1854 m3 w kanalizacji C i 5846 m3 w kanalizacji D. Za przyczynę dopływu wód roztopowych do kanalizacji uznano otwory we włazach studzienek rewizyjnych oraz nielegalne podłączenia rynien dachowych lub wpustów podwórzowych do kolektorów sanitarnych.
EN
The aim of the study was to define the scope of the spring snowmelt impact on the increase of inflow to the separated sewer system sewage treatment plant. The research was carried out from 1st January 2010 to 31st March 2010 in four selected sewer systems located in the Lesser Poland voivodeship. Hourly air temperature and daily sewage flow measurements were performed. Intensive snowmelts in 2010 began on 19th February and ended on 4th March. The average inflow percentage in the sewage discharge to each treatment plant during the snowmelt season reached from 36.6% to 58.1%. The highest inflows occurred on 1st March (average daily air temperature – 6.6°C), and their percentage compared to the average daily flow at the rainless weather reached respectively: 56.8% in the sewer system A, 74.3% in the sewer system B, 54.7% in the sewer system C and 76.5% in the sewer system D. These numbers indicate that inflow caused by the snowmelts constituted over 50% of the daily flow in all analysed sewer systems. The following amount of inflow was discharged into the analysed sewer systems during the greatest snowmelts, i.e. from 19th February to 3rd March 2010: 3641 m3 into the sewer system A, 6926 m3 into the sewer system B, 1854 m3 into the sewer system C and 5846 m3 into the sewer system D. Openings in the inspection chamber manholes as well as illegal connections of gutters and yard inlets to the sanitary sewers were considered as the cause of melt-water discharge into the sewer systems.
PL
W pracy poddano analizie zagospodarowanie gruntów wybranych miejscowości gminy Jelcz-Laskowice po kątem przydatności rolniczego wykorzystania ścieków do nawodnień. Na podstawie dostępnej literatury przedstawiono możliwości zagospodarowania ścieków pochodzących z trzech położonych obok siebie sołectw: Biskupice Oławskie, Minkowice Oławskie i Wójcice. Wskazano korzyści wynikające z proponowanego rozwiązania, a także przeanalizowano istniejącą infrastrukturę techniczną oraz możliwości jej rozbudowy.
EN
Management of the grounds in selected localities of the Jelcz-Laskowice commune was analysed in regard to agricultural utilization of sewage for irrigation of energetic crops. Basing upon available literature data, the possibility of using sewage coming from three neighbouring villages was assessed. The advantages resulting from the solutions proposed were emphasized considering the existing technical infrastructure and the possibility of its development.
PL
W pracy przedstawiono wyniki badań dotyczące skuteczności pracy obiektów roślinno-glebowych w latach 2002-2005. Oczyszczalnie roślinno-glebowe stanowią korzystne rozwiązanie oczyszczania ścieków na terenach bez centralnej kanalizacji. Charakteryzują się niskimi kosztami utrzymania oraz wysoką skutecznością pracy, która wynosi dla BZT₅ powyżej 98%, natomiast dla azotu ogólnego 87%. Wybrane obiekty roślinno-glebowe w trakcie trwania badań pracowały w warunkach niekorzystnych, związanych z nierównomiernym dopływem ścieków surowych, przeciążeniem złoża ładunkiem zanieczyszczeń oraz niskimi temperaturami w okresie zimowym. Pomimo tak niekorzystnych warunków nie zaobserwowano spadku skuteczności oczyszczania ścieków na tych obiektach.
EN
The paper presents research results concerning the treatment efficiency in the plant-soil treatment plants in 2002-2005. The plant-soil treatment plants are the example of a good solution for sewage treatment in rural areas without a central sewage system. These objects are characterized by low costs of operating as well as high treatment efficiency for BOD₅ of above 98% and for total nitrogen of 87%. During the research, selected plant-soil treatment plants were worked in the disadvantageous conditions connected with the unequal sewage supply, pollutions charges overloaded and low air temperatures in winter period. In spite of these conditions there was no fall in the treatment efficiency.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.