Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 17

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  hip-joint
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this work the assessment of the relation between the scale of the destruction of the hip joint according to Choi et al. classification and the movement range in this joint was carried out. The material encompassed 27 patients (30 hip joints) who underwent the assessment of the movement of flexion, extension, adduction, abduction, as well as external and internal rotation. The link between the scale of the destruction of the joint and the scale of the movement limitation was not found.
PL
Największy z ludzkich stawów - staw biodrowy - często narażony jest na różne uszkodzenia i zwyrodnienia. Poznanie jego funkcjonowania i charakterystyk mechanicznych jest kluczową kwestią w procesie projektowania endoprotez, czy wykonywaniu takich zabiegów, jak osteotomie. Przeprowadzono analizę stanu odkształceń metodą tensometrii oporowej i przemieszczeń metodą ESPI na powierzchni ludzkiej kości miednicznej w okolicy panewki stawowej. Rezultaty pokazują zmniejszenie się wartości przemieszczeń i wzrost wartości odkształceń po implantacji polietylenowej sztucznej panewki stawowej.
EN
The largest from human joints - hip joint - is often endangered for different damages and degeneration. To know it's functioning and mechanical profiles is fundamental point in such issues as artificial joint designing process or executing operations like osteotomies. The analysis of deformations' state by strain gauges and displacements' by ESPI method on the human pehdc bone's surface in acetabulum region was conducted. The results show the decrease of displacements' value and increase of deformations' value after implantation of poliethylene artificial cup.
PL
W pracy opisano sposób modelowania ludzkiego stawu biodrowego na podstawie zdjęć z tomografii komputerowej preparatów anatomicznych. Przedstawiono również zadawanie parametrów materiałowych zarówno dla kości udowej, jak i miedniczej człowieka oraz elementów sztucznego stawu biodrowego (po zabiegu kapoplastyki). Opracowano dwa modele: jeden dla zdrowego stawu biodrowego, drugi po zabiegu kapoplastyki. W końcowym etapie wykonano analizę wytrzymałościową obu modeli oraz porównano wyniki.
EN
In this work the way of creation FEM model of human hip-joint based on CT scans is shown. The modeling of material parameters for femur and pelvis bone is also shown. Two models were prepared: first for good- health hipjoint, and second for hip-joint after operation of resurfacing. Finally the analysis of static loading was done for both models and the results were compared.
PL
W pracy przedstawiono stanowisko do badania zmian długości mięśni za pomocą czujników pomiarowych linkowych oraz kątów działania sił mięśniowych występujących w stawie biodrowym w różnych fazach ruchu człowieka. Do badań wykorzystano model anatomiczny w skład, którego wchodzą: dwie połówki kości miednicznej, kość krzyżowa, fragment kręgosłupa lędźwiowego, kość udowa i kość piszczelowa.
PL
W czasie udaru lub silnego impulsu działającej siły uderzeniowej zmienia się gwałtownie wysokość szczeliny stawu a w związku z tym zmieniają się istotnie parametry smarowania powierzchni stawowych, Te fakty mają znaczący wpływ na negatywne skutki wywołane udarem. Niniejsza praca zawiera obliczenia numeryczne rozkładów ciśnienia hydrodynamicznego oraz sił nośnych w stawie biodrowym człowieka podczas niestacjonarnego impulsowego obciążenia. Zakłada się, że rozkład ciśnienia odbywa się na wycinku sfery stawu biodra i na krawędziach tego wycinka panuje ciśnienie atmosferyczne.
EN
This paper shows numerical comparisons between lubrication of human hip joint gap in unsteady impulsive motion. We assume that spherical bone head in human hip joint moves at least in two directions namely in circumference and meridian directions. Basic equations describing synovial fluid How in human hip joint are solved on the analytical and numerical way. Numerical calculations are performed in Mathcad 11 professional program, taking into account the method of finite differences. This method satisfies stability of numerical solutions of partial differential equations and gives real values of pressure and capacity forces occurring in human hip joints.
PL
Celem pracy jest utworzenie oprogramowania wspomagającego lekarza podczas procesu doboru endoprotezy stawu biodrowego. Dobór implantu jest oparty na odpowiednich kryteriach zapisanych w postaci funkcji celu. W przypadku protez, które nie spełniają w zadowalającym stopniu narzucony im warunkowa możliwe będzie utworzenie protezy na miarę.
EN
The paper is devoted to software development to support a surgeon in a process hip joint prosthesis selection. The process is based on suitable criteria having a form of an objective function. In the case when the standard value of the objective function for a given prosthesis is not satisfactory enough the custom-designed prosthesis can be made.
7
75%
PL
Skostnienia okołostawowe są ważnym problemem klinicznym, społecznym i technicznym. Jeżeli problem tego rodzaju występuje w obrębie stawu biodrowego, to poprzez jego unieruchomienie w danym kącie, uniemożliwiającym ruch, powoduje utrudnienie w korzystaniu z wózka w pozycji siedzącej, przy zachowaniu kąta pomiędzy tułowiem a kością udową wynoszącego 90 stopni. Powoduje to niebezpieczne zsuwanie się użytkownika z wózka, co grozi w rezultacie niebezpiecznym upadkiem. W części przypadków uniemożliwia to wręcz korzystanie z wózka, skazując osobę z nie pełnosprawnością na pozostawanie w łóżku, co drastycznie obniża jej jakość życia, w tym życia zawodowego.
EN
Using the system approach, the paper deals with the problems of ceramic head of hip joint endoprosthesis destructions, and with assessing the impact of shape deviations of conical surfaces on the tensile stress under different loading. Concerned are shape deviations from the ideal conical surfaces of the stem and the head of the endoprosthesis, which - when the head is put on the stem and the endoprosthesis loaded - form a contact configuration. The shape deviations may be modelled at the macro-level - this concerns model shape inaccuracies such as deviation from the nominal degree of taper, ovality, and their combination, or, possibly, at the micro-level - when the stochastic distribution of unevenness on the contact areas is respected. The problem of stress in ceramic heads was solved using the algorithm of the finite element method for spatial contact tasks. In the paper are presented and analysed the results of solution of the micro-level shape deviations, obtained from measurements made on the cones of stems and heads under the loading obtained from the experiments [1] and under ISO 7206-5 loading [2].
EN
In the present contribution, the problem of the wear particle generation and transport is considered. It is assumed that this process can be described by the diffusion equation proposed recently by Shillor et al. First the contact problem is solved numerically for a realistic loading scenario on a generic joint geometry and the necessary source terms for the diffusion equation are obtained. Then, the diffusion in the area of the acetabulum is considered. Qualitative data on the wear particle flux to the joint space are obtained and discussed.
EN
In this paper the model for the dynamic analysis of stress and strain distribution in chosen parts of the hip joint, especially of the femur, under changing forces of muscles and given external loadings was presented. The femur and the implanted femur, which is femur - cement - implant structure, was taken into account. The geometry modification around the thigh bone and the implant enables to estimate a sensitivity of the proposed model. A solution of the dynamics task will allow to explain reasons of bone and implant damages caused by certain types of movements from a point of view of bone tissue strength criterion and materials used for the alloplasty. Some problems concerning a creation of numerical femur models in computational environments using MES techniques are discussed. The modelling of "flexion - extension" and "abduction - adduction" movements in the hip joint under an influence of muscles and given external loadings are described. A stress and strain distribution of chosen hip joint parts, as functions of time, can be achieved from the forward and inverse dynamics task solution. The possibility of forward dynamics task solution allows in future the learning method development of new movements by lower extremity and the way of muscles controlling. Moreover, analysis of exercises usually carried out during rehabilitation can be very helpful in identifying activities with possibly hazardous musculoskeletal loading and thus improve the outcome of rehabilitation after the hip joint alloplasty.
EN
In presented approach a pre-operative selection of an optimal implant relies on comparative analysis of three type models: (a) CT-based, parametric geometric model of patient's hip joint ( femoral bone identification with accurate head location); (b) parametric geometric model of optimal implant for cemented or uncemented hip replacements, derived from (a); (c) parametric geometric models of implants, available for the surgical operation (hospital data base). Comparative analysis and results of optimization (combinatorial-cyclic method) are output graphically and in ranking tables within frames of integrated CAD/CAM/CAE systems (Unigraphics-NX3 or other systems). The objective function of the optimization has a multi-variable structure, and can be set according to a surgeon's requirements.
EN
The paper presents the solving of the problem of the stress states in the ceramic head of hip joint endoprosthesis. This problem is very important today, because there had occurred the destruction of the ceramic head among a non-negligible number of patients. The values of the head stress and reliability are significantly influenced by the existence of the modeled production inaccuracies on the head and the stem contact areas. Therefore, the first part of the paper presents the results of the stress in the ceramic head under the oblique loading which simulates the physiological ones. The second part presents the results from the production inaccuracies measuring, which will be implemented in the FEM model as geometrical input.
PL
W pracy opierając się na zastosowaniu metody elementów skończonych oraz eksperymentalnych metod z zakresu mechaniki ciała stałego przedstawiono analizę mechanicznych właściwości implantów. Omówiono wpływ cech geometrycznych i materiałowych trzpieni i panewek endoprotez stawu biodrowego na proces ich adaptacji w ludzkim organizmie. Określono istotne mechaniczne właściwości implantów, które determinują ich cechy biologiczne. Stwierdzono, że prognozowanie właściwości biologicznych i zachowania się nowych implantów w organizmie człowieka może opierać się na metodach z zakresu mechaniki materiałów.
EN
The paper presents methods of analysis the mechanical behaviour of implants including the finite element methods and laboratory mechanical experiments. The influence of the method of the artificial hip joint stem fixation into the femoral bone on its adaptation process in the human organism has been given reasons in this work. The important mechanical properties of implants, which influence its biological features, have been determined. It has been stated, the biological behaviour prediction of new implant structures could be made on the basis of methods from the mechanics of materials.
EN
The paper concerns new construction of type series of polish hemi-endoprostheses of the hip joint. Clinical assumptions, simulation studies and clinical prototypes were presented. According to author's knowledge it is one of the first introductions of new generation, polish, modular hemi-endoprosthesis of the hip joint.
|
|
tom z. 6
65-70
EN
The numerical calculations for three components of the synovial fluid velocity vector were considered and discussed in this paper. The analytical formulae for the components of the fluid velocity vector were obtained in the other author's paper. The presented calculations were performed for the model of the changeable height of the biobearing gap in the axially-symmetric synovial fluid flow occurring between two rotational spherical surfaces of the human hip joint
PL
W pracy przedstwione zostały obliczenia numeryczne współrzędnych wektora prędkości cieczy synowialnej w szczelinie biołożyska. Rozwiązania analityczne uzyskano wcześniej. Obliczenia numeryczne wzraz z interpretacją przeprowadzono dla przyjętego modelu zmiennej wysokości szczeliny w osiowo-symetrycznym przepływie cieczy synowialnej występującym pomiędzy dwiema obrotowymi powierzchniami sferycznymi stawu biodrowego człowieka.
PL
W pracy zweryfikowano przydatność optymalizacji parametrycznej dla płaskiego modelu biomechanicznego reprezentującego kończynę dolną człowieka. Optymalizacji został poddany sposób zadawania ciosu ap-chagi w aspekcie minimalizacji czasu przebiegu tego uderzenia. Uzyskane rezultaty przedstawiono w postaci optymalnych przebiegów momentów sterujących w stawach kończyny dolnej i reakcji w stawie biodrowym. Wykazały one, iż nie wszystkie sterowania optymalne, choć numerycznie możliwe, są akceptowalne z fizjologicznego punktu widzenia.
EN
An inverse dynamic parametric optimization method for solving optimal control problems involving planar biomechanical models is discussed. The method is applied to minimize the performance time of an ap-chagi kick. The optimal time characteristics of the net torques at the basic joints of a leg and driving reactions in the hip joint are presented. The obtained results are interpreted in terms of their relevance to the activity under study.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.