1
Content available remote A Robust Deadbeat Control Scheme for Active Power Filter with LCL Input Filter
100%
EN
This paper proposes a novel robust deadbeat control scheme for the active power filter with LCL input filter. The selection of the current loop gain is discussed by using root locus diagram representation to ensure stability of the closed-loop control algorithm. A feed-forward plus feedback control structure is adopted to achieve accurate steady-state performance and fast dynamic response by using the adaptive linear neural network (ANN) harmonic detection scheme. The validity of the control scheme is verified by the extensive simulation and experimental results.
PL
Artykuł przedstawia nowy odporny system sterowania dla aktywnych filtrów energetycznych z wejściowym filtrem LCL. Dobór wzmocnienia pętli prądowej jest analizowany dla zapewnienia stabilności sterowania przy zamkniętej pętli. Zaadaptowano sprzężenie do przodu i sprzężenie zwrotne dla dokładnego osiągnięcia stanu ustalonego i szybkiej odpowiedzi dynamicznej przy wykorzystaniu adaptacyjnej liniowej sieci neuronowej. Jakość sterowania potwierdzono badaniami symulacyjnymi i eksperymentalnymi.
EN
This paper reports a hybrid power quality compensation scheme based on a combination of dynamic reactive power compensator and a dual active power filters (APF) topology configuration. The parameter designing procedure for reactive compensator and the control strategy for the dual active power filters are presented. The proposed compensation scheme was practically implemented for power quality mitigation project of Shanghai Volkswagen (SVW) Company. The validity and effectiveness of the proposed compensation scheme is verified by the field test results.
PL
W pracy przedstawiono hybrydowy układ kompensacji jakości energii składający sie z dynamicznego kompensatora mocy biernej I podwójnego filtru aktywnego. Przedstawiono procedurę projektową kompensatora mocy biernej i strategię sterowania filtrami aktywnymi. Proponowany system był zastosowany w Shanghai Volkswagen (SVW) Company. Jakość i skuteczność metody została zweryfikowana w warunkach pracy.
EN
This paper proposes an LCL-filter-based hybrid active power filter for harmonic mitigation and reactive power of a 10/0.4kV residential distribution system. Adaptive linear neural network (ADALINE) is applied for individual harmonic component extraction from distorted nonlinear load currents, and the estimated signals are used for the selective harmonic elimination (SHE) purpose in the current-loop controller. A robust deadbeat current control law is derived based on the low frequency model of the presented topology. By using the ADALINE based SHE strategy, the currentloop controller bandwidth is significantly reduced thus the stability of whole system is ensured. The proposed control algorithms were digitally implemented in TMS320F2812 DSP controllers, where the dual DSP plus FPGA hardware configuration was adopted for precise signal conditioning and calculation. Both the laboratory experiments and field tests are implemented. The feasibility and effectiveness of the proposed system have been substantially confirmed by the laboratory experiments and field tests, which were obtained from the practical installation of the prototype systems in a residential distribution system as well as in the distribution system in the punching shop of an auto manufactory factory.
PL
W artykule zaproponowano aktywny filtr LCL do tłumienia harmonicznych i mocy biernej w 10/0.4 kV lokalnej sieci rozdzielczej. Wykorzystano adaptacyjną sieć neuronową do ekstrakcji harmonicznych z prądów odkształconych a wyznaczony sygnał zastosowano do selektywnej eliminacji harmonicznych. Odporny układ kontroli prądu bazuje na niskoczęstotliwościowym modelu sieci. Dzięki proponowanej strategii pasmo kontrolera jest zredukowane a stabilnosć poprawiona. Proponowany algorytm implementowano wykorzystując procesor typu TMS 320F2812 w którym adaptowano podwójny DSP i FPGA układ do precyzyjnego kondycjonowania sygnału i obliczeń. Testy laboratoryjne potwierdziły skuteczność algorytmu. System sprawdzono w lokalnej sieci rozdzielczej w fabryce samochodów.
4
Content available remote Perfect Harmonic Cancellation Strategy for Three-Phase Four-Wire APF
84%
EN
This paper evaluates the performance of four load compensation strategies for a three-phase four-wire system, namely, the p-q method, id-iq method, unity power factor (UPF) method and the perfect harmonic cancellation (PHC) method. The PHC is found to be the best candidate under distorted and unbalanced grid voltage conditions. Excellent steady-state and dynamic performance is achieved by using the presented PHC scheme. Finally, extensive simulation results are provided for verification.
PL
W artykule oceniono strategię kompensacji składowej biernej w układzie czteroprzewodowym metodą p-q, metodą id-iq, metodą współczynnika mocy UPF i metodą eliminacji harmonicznych PHC. Stwierdzono, że najlepsze wyniki w niezrównoważonej sieci napięciowej daje metoda PHC. Wyniki symulacji potwierdzono eksperymentalnie.