Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 51

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  generator indukcyjny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
1
100%
EN
Wind power plants are classified such as perspective and ecologic sources of electric energy. The problems of wind power plants running with induction generators is solved within partial target of research project. Presentation of results from measuring running states at selected wind power plants for different type of switching to distributive network is assumed within the manuscript. In the concrete, the analysis of switching transient phenomena, the analysis of power flow and the determination of a back influence on the distributive network are described in detail.
PL
Pola elektrowni wiatrowych są uznawane za perspektywistyczne i ekologiczne źródła energii elektrycznej. W artykule omówiono problematykę elektrowni wiatrowych, w których zastosowano generatory indukcyjne. Zaprezentowano wyniki pomiarów elektrycznych dokonanych podczas normalnej pracy wybranych elektrowni wiatrowych, w których zastosowano różne sposoby podłączenia generatorów do sieci dystrybucji energii. Przede wszystkim przedstawiono analizy zjawisk przejściowych, występujących przy podłączaniu elektrowni wiatrowej do sieci energetycznej, analizę rozpływu energii oraz przedstawiono sposoby określania negatywnych wyników oddziałujących na sieć energetyczną, a związanych z przyłączaniem i pracą w tej sieci elektrowni wiatrowych.
PL
Opisano konstrukcję i metodykę badań impulsowego generatora indukcyjnego, który ma być źródłem energii elektrycznej w artyleryjskim zapalniku programowalnym. Rdzeń generatora rozpoczyna ruch po ścięciu przepony, co odpowiada przekroczeniu granicznej wartości przyspieszenia postępowego pocisku poruszającego się w lufie. Zaproponowana metodyka badań generatora polega na wystrzeliwaniu rdzenia za pomocą sprężonego powietrza. Ruch rdzenia rozpoczyna się po zerwaniu przepony, gdy ciśnienie powietrza przekroczy wartość graniczną, która odpowiada obciążeniu rdzenia siłą bezwładności podczas strzału. Podczas eksperymentu rejestrowano w funkcji czasu ciśnienie działające na rdzeń oraz napięcia na cewce generatora i na ładowanym przez generator kondensatorze. Układ był analizowany jako obwód RLC w stanie nieustalonym. Przeprowadzono dynamiczną identyfikacje parametrów obwodu i symulacyjne badania wpływu wartości parametrów na napięcie na kondensatorze.
EN
The generator to initiate the prime in fuze for cartridges and it’s methods of study has been described. It consists of a stator with coil of wire and permanent magnet 6 mm diameter core. The core begins its movement as a diaphragm is ruptured, during cartridge acceleration in a gun barrel. Thus generator acts reverse to a coil-gun set. The generator was investigated on a special test stand, with compressed air as a driving medium. The pressure, voltage drop across the coil and the voltage on a condenser was measured as a function of the time. Results of numerical investigations of the RLC circuit, as a simplified model of the generator, are also presented.
3
80%
EN
Induction generator can work connected to power system or connected to separated system. Induction machine work can as generator only at this time, when reactive power is delivered to machine. Special selected capacitors were connected to the motor for realization this task. It is possible to use this generator as energy source in small water or wind power plant. Authors call special attention for stabilization of amplitude and frequency of generated voltage.
EN
Induction generator can work connected to power system or connected to separated system. Induction machine work can as generator only at this time, when reactive power is delivered to machine. Special selected capacitors were connected to the motor for realization this task. It is possible to use this generator as energy source in small water or wind power plant. Authors call special attention for stabilization of amplitude and frequency of generated voltage. Measurements and time registration for non-symmetrical load are presented in this paper.
EN
The paper presents the problems of control of isolated self-excited induction generator used to operate under variable speed. The systems of three-phase isolated induction generator with excitation from a three-phase PWM inverter with a single capacitor on the DC side are presented. The use of a static PWM inverter for controlling of induction generator excitation gives a better transient response and a smooth variation of excitation current. The systems of PWM excitations with PWM inverter placed in series or shunt with induction generator and hybrid system are presented. The vector control methods of self-excited induction generator are developed and discussed. The control schemes based on generator magnetic field orientation are presented. The direct and indirect control based on rotor flux orientation and control based on direct stator flux orientation are described. The stator flux oriented vector control requires decoupling blocks in the control circuits. Some selected results of simulation of control performance are presented.
EN
The paper presents the problems of vector converter control of isolated self-excited induction generator. The converter systems of three-phase isolated induction generator with excitation from a three-phase PWM inverter with a single capacitor on the DC side are presented. The use of a static PWM inverter for controlling of induction generator excitation gives a good transient response and a smooth variation of excitation current. The system of PWM excitation with PWM inverter placed in series with induction generator is presented. The vector control methods of self-excited induction generator are developed and discussed. The control schemes based on generator magnetic field orientation are presented. The direct and indirect control based on rotor flux orientation and control based on direct stator flux orientation are described. Some selected results of simulation of control performance are presented.
EN
The main advantage of the variable speed power generation systems with slip-ring induction generator related to cage or synchronous generator is low power and low costs of the power electronics. As the speed range is limited the power converter can be designed on few percent of the generator power, that provide lower losses and costs and higher efficiency. The Direct Voltage Control method of slip ring induction generator is presented in this paper. This method bases on stator voltage vector feedback, that permits the generator can operate as a stand-alone set e.g. in island power systems. Moreover an autonomous operation mode provide the grid connected generator is useful even after the mains outage and can supply isolated part of a grid load. The Direct Voltage Control method uses a space vector theory. A stator voltage vector represented in the reference frame rotating with synchronous speed has fixed magnitude and position when the stator voltage amplitude, frequency and phase are fixed. To obtain the fixed values of the voltage vector amplitude and position, two voltage regulators are applied. One of them based on reference and actual stator voltage amplitude is responsible for rotor current amplitude. The second regulator based on reference and actual stator voltage angle referred to synchronous frame is responsible for rotor current frequency. Applied stator voltage control method do not use any information about the rotor speed or position, therefore it can be called sensorless. Moreover an instantaneous value of the generated stator voltage is controlled that provide not only fixed voltage frequency and amplitude but also controlled voltage phase. This is an important advantage in grid and generated voltage synchronization process.
PL
W artykule opisano układ autonomicznego generatora w układzie maszyny pierścieniowej z tranzystorowym przekształtnikiem w obwodzie wirnika. Generator pracuje zasadniczo podsynchronicznie przekraczając prędkość synchroniczną w zakresie poślizgu znamionowego. Wirnik maszyny synchronicznej jest zasilany ze stojana poprzez przekształtnik diodowo-tranzystorowy z pośrednim obwodem napięcia stałego. Natomiast stojan jest źródłem napięcia trójfazowego o stałej częstotliwości. Stabilizację napięcia i częstotliwości osiągnięto poprzez zastosowanie sterowania z wykorzystaniem orientacji względem wektora przestrzennego zadanego napięcia stojana. Do opracowania układu wytwarzania energii wykorzystano program symulacyjny PSIM zawierający pliki DLL z modelem maszyny i algorytmem sterowania. Plik zawierający algorytm sterowania wykorzystuje się bezpośrednio do programowania procesora sygnałowego. Zaprezentowano wyniki badań symulacyjnych oraz laboratoryjnych układu modelowego z maszyną pierścieniową 380/220V/1,5kW. Wyniki badań obejmują stany ustalone z liniowymi i nieliniowymi odbiornikami oraz w stany przejściowe wywołane skokowym załączeniem obciążenia.
EN
The paper presents theory and results of tests of variable speed stand alone generating system. The system consists of double fed induction machine and power electronic converter. A topology and control system permits stand alone operation. However, an initial excitation is needed. After, short, preliminary excitation, from the external source, the system operates autonomously and continuous excitation power is assuring by stator power. A control system is based on stator voltage space vector referred to rotating frame. The speed of the rotating frame responds to stator frequency. The system is controlled by rotor current that amplitude is adjusted by controller of the stator voltage component related to x axes, whereas the rotor current frequency is controlled by stator voltage component related to y axes. In this way the stator output voltage frequency is speed independent an the control system operates without any mechanical sensor. For design a simulation program PSIM with DLL files is applied. The DLL file with control algorithm is directly used for DSP programming. Results of controllers calculation in wide speed range are presented. Laboratory system 380/220V/1.5kW was built and tested. As a controller a DSP Sharc(TM) system with support ALTERA(TM)/FPGA is used. Results of laboratory tests presents the generating system in transients when a step load is applied. Steady state voltage for case of nonlinear, three-phase load is represented. .
PL
W artykule przedstawiono model matematyczny przekształtnikowego układu autonomicznego generatora indukcyjnego z obciążeniem w obwodzie prądu przemiennego generatora. Układ sterowania obejmuje sterowanie amplitudą napięcia na zaciskach generatora oraz sterowanie napięciem stałym w obwodzie pośredniczącym przekształtnika AC/DC. Przedstawiono algorytm sterowania zmiennymi elektromagnetycznymi oraz schemat strukturalny układu sterowania. Przedstawiono metodę doboru nastaw regulatorów prądu przekształtnika AC/DC i amplitudy napięcia w obwodzie prądu stałego oraz przemiennego. Przeprowadzono syntezę pracy układu sterowania. Wyniki syntezy pozwalają na racjonalny dobór nastaw regulatorów w przekształtnikowym układzie sterowania autonomicznym generatorem indukcyjnym zapewniający dużą dokładność sterowania, nawet przy dużych zmianach obciążenia oraz prędkości kątowej generatora.
EN
In the paper the algorithm and control method of converter system of autonomous induction generator are presented. The mathematical model of the system was given. The methods of tuning of inverter current controllers in the AC side circuits, the generator voltage controller and the voltage controller in DC link voltage of converter are described. The system enables dynamic control of voltage at the stator terminals of an induction generator with various types of loads of the generator. The simulation results of the studies are presented in the second part of this article.
10
Content available remote Analiza warunków wzbudzenia autonomicznego generatora indukcyjnego
80%
PL
W artykule przedstawiono analizę warunków niezbędnych dla uzyskania samowzbudzenia autonomicznego generatora indukcyjnego. Przedstawiono modele autonomicznego generatora indukcyjnego do analizy stanów statycznych i stanów nieustalonych. Na podstawie tych modeli przeprowadzono analizę statyczną i dynamiczną procesu samowzbudzenia generatora indukcyjnego. W analizie statycznej warunki samowzbudzenia zostały określone na podstawie charakterystyk statycznych generatora i kondensatorów wzbudzenia. W analizie dynamicznej warunki samowzbudzenia zostały określone na podstawie operatorowych równań stanu i pierwiastków równania charakterystycznego macierzy stanu. Wykazano, że metoda analizy dynamicznej pozwala na dokładniejsze określenie warunków koniecznych do samowzbudzenia generatora indukcyjnego i zasad doboru parametrów obwodów dołączanych do generatora.
EN
The paper presents an analysis of the necessary conditions to achieve self-excitation of autonomous induction generator. The models of the autonomous induction generator for the analysis of static and transients states are presented. Based on these models the analysis of steady-state and transient process of self-excitation of induction generator was performed. In steady-state analysis the self-excitation conditions were determined on the basis of static characteristics of the generator and excitation capacitors. In dynamic analysis the self-excitation conditions were determined on the basis of operator form of state equations and roots of characteristic equation of state matrix. It was shown that the method of dynamic analysis allows to more accurate define the necessary conditions for self-excitation of induction generator and the rules for design of parameters of circuits connected to the stator of generator.
EN
So far, much attention has been not received by the influence of the control modes on the wind turbine efficiency in maximum wind energy extraction, which is investigated based on variable speed wind turbines with doubly fed induction generator (DFIG) under vector control in stator flux orientation (SFO) in the paper. Prior art has tended to have an importance on investigating the principle and behaviors of control strategies in itself. As a result, two control modes, optimal rotor speed control mode and peak power control mode is investigated in detail. At first, Stator flux-orientated vector control for the rotor side converter of DFIG is reviewed, and in turn a comparison on two control modes is presented. Finally, a complete simulation model is developed to investigate how the operation of maximum wind energy extraction of the turbine below rated wind velocity, especially the wind turbine efficiency is affected by the two control methods. Simulation results are presented and compared under the two different control modes. Simulation results show that maximum wind energy extraction of the turbine and its efficiency is affected by different control modes.
PL
W artykule porównano różne strategie zarządzania systemem elektrowni wiatrowych z podwójnie zasilanym generatorem indukcyjnym. Jedna ze strategii polega na kontroli optymalnej prędkości wirnika, druga na kontroli mocy szczytowej.
PL
W artykule opisano metodę kompensacji mocy biernej dla elektrowni z generatorem indukcyjnym. Kompensację mocy biernej zrealizowano z wykorzystaniem przekształtnika trójpoziomowego. Sterowanie kompensatorem bazuje na metodzie zorientowanej napięciowo. W artykule przedstawiono i omówiono strukturę sterowania kompensatorem, pokazano wyniki badań komputerowych oraz laboratoryjnych. Badania laboratoryjne przeprowadzono na generatorze indukcyjnym o mocy 7,5 kW.
EN
The paper presents a method of reactive power compensation for power plants with an induction generator. The reactive power compensation has been done using three-level power converter. A control of the power converter bases on voltage oriented method. In the paper, the control structure has been shown and described. Moreover, the simulation and laboratory results have been presented. Laboratory tests were done using 7.5 kW induction generator.
13
Content available remote Wyznaczanie parametrów małej elektrowni wodnej
70%
PL
Opisano przemiany energii w malej elektrowni wodnej. Podano zależności na energię strumienia wody, przekazywaną turbinie i produkowaną przez generator oraz dostarczaną do sieci. Przykład obliczeniowy dotyczy układu 3 generatorów indukcyjnych po 30 kW, napędzanych turbinami Kapłana o średnicy 0,9 m przez przekładnie o przełożeniu 4,3.
EN
Energy conversions in the small hydroelectric plant were described. Equations of water jet energy, transmitted to the turbine, produced by generator, and supplied to the power network were presented. In the analytical example system of three induction generators 30 kW each, driven by Kaplan turbines of 0.9 m diameter with gear ratio 4.3 was presented.
14
Content available remote Kompensator mocy biernej dla elektrowni wodnej z generatorem indukcyjnym
70%
PL
W artykule przedstawiono zagadnienia kompensacji mocy biernej w małych elektrowniach wodnych z generatorem indukcyjnym. Omówiono kompensację kondensatorową oraz zaproponowano zastąpienie jej przekształtnikowym układem kompensacji mocy biernej. W artykule przedstawiono metodę sterowania aktywnym kompensatorem oraz pokazano wyniki badań komputerowych. Opracowana metoda sterowania została zweryfikowana na stanowisku laboratoryjnym z silnikiem indukcyjnym o mocy 7.5 kW.
EN
The paper presents a reactive power compensation for small hydropower plants with an induction generator. The classic compensation with capacitors is discussed. The paper proposes improvement of such compensation. Instead capacitors, the power converter can be used to reactive power compensation. The control structure and simulation results are presented. The laboratory tests has been done on 7.5 kW induction generator.
15
Content available remote Układ sterowania małą elektrownią wiatrową z generatorem indukcyjnym
60%
PL
W referacie przedstawiono układ sterowania małej, zasilanej z 1 fazy elektrowni wiatrowej, w której wykorzystano generator indukcyjny z przekształtnikiem energoelektronicznym i zasobnikiem energii w postaci kondensatora i dławika. Przeprowadzono badania symulacyjne zasobnika energii oraz przedstawiono realizację aplikacyjną z silnikiem wiatrowym o mocy 12kW. Badania symulacyjne jak i doświadczenia eksploatacyjne wykazały dobre właściwości bezczujnikowego regulacji silnika asynchronicznego pracującego jako generator oraz możliwość oddawania energii do sieci jednofazowej z zachowaniem stałego napięcia w obwodzie pośredniczącym.
EN
The structure of control systems of small, 1 phase wind power station based on 3 phase induction generator are presented in the paper. Optimizing costs the inverter with small energy storage was designed to assure minimization of capacitance of main capacitor. The control algorithm is proposed taking into account instant power generated by wind turbine. Experimental and simulation results are presented in the paper. Examinations have shown good qualities of 3 phase induction motor control systems and energy conversion to 1 phase grid.
PL
Rozpatrywany w referacie generator indukcyjny z maszyną dwustronnie zasilaną w układzie bezstykowym składa się z dwóch sekcji maszyn indukcyjnych, których wirniki połączono sztywno ze sobą mechanicznie oraz elektrycznie i zamknięto w jednej obudowie. Zaletą takiego układu jest wyeliminowanie styków ślizgowych przy zachowaniu możliwości dwustronnego oddawania energii. W referacie przedstawiono model matematyczny i schematy zastępcze generatora indukcyjnego w układzie bezstykowym jak również dokonano analizy wybranych stanów pracy układu generatora z przekształtnikiem w programie symulacyjnym PSIM.
EN
Brushless doubly fed induction generator investigated in the paper consists of two doubly fed induction machines, whose rotors are mechanically and electrically coupled. The main advantage of considered doubly fed machine is possibility of power generation with elimination of slip rings and brushes. Mathematical models and equivalent circuit of brushless doubly fed induction generator are presented in the paper. Theoretical analysis is verified by simulations using PSIM software.
EN
The phenomenon of the self-synchronisation in line-start synchronous machines can be suitably used in distributed generation plants. With a simple control equipment based on contactors, it is possible to overcome the restrictions imposed to the synchronous generators in some countries. The paper shows that synchronous machines can be suitable also when both stand-alone and grid-connected operations are involved. The paper reports finally a comparison with an equivalent system based on induction machines by means of experimental tests on sample test benches with the target to put in evidence the different characteristics of the two plant typologies.
PL
W artykule wykazano że generator synchroniczny może być z powodzeniem użyty jako jednostka samodzielna i w lokalnej sieci. Porównano dwie sieci – z generatorami synchronicznymi i indukcyjnymi.
PL
Generatory indukcyjne klatkowe cechuje łatwość przyłączenia do sieci elektroenergetycznej i duży zapas stabilności. Cecha ta spowodowała dość obszerne ich wykorzystanie w małych elektrowniach o niezbyt stabilnym niekontrolowanym napędzie, np. w elektrowniach wiatrowych i wodnych. Jednakże generatory te, jako źródło energii czynnej, mają niekorzystną cechę w postaci dużego zapotrzebowania na energię bierną indukcyjną. W zasadzie oczekuje się, aby źródło energii elektrycznej dostarczało zarówno mocy czynnej, jak i mocy biernej, tak jak np. generatory synchroniczne z uzwojonym wirnikiem. Natomiast generator indukcyjny (asynchroniczny), np. o 3 parach biegunów i mocy znamionowej 110 kW, pobiera ok. 60 kVAr mocy indukcyjnej (prąd indukcyjny 86 A). Wraz ze zmianą punktu pracy generatora zmianie ulega wartość generowanej przez niego mocy czynnej, a także i pobieranej mocy biernej. W sytuacji braku obciążenia prąd biegu jałowego, czyli prąd indukcyjny, wynosi 66 A. Tak znaczne wartości prądu biernego pobieranego z sieci są przyczyną powstawania strat energii czynnej w sieci dystrybucyjnej. Dla zapobieżenia tym stratom wprowadzono obciążenia finansowe za pobór energii biernej przez małe elektrownie stosujące generatory indukcyjne.
EN
Paper describes reactive power compensation of generation systems proposed to small hydro power station. In small hydro power stations are usually applied as generators cage induction (asynchronous) machines. The induction generator, connected directly to grid, delivers active power but simultaneously is significant consumer of reactive lagging power. Conventional compensation, related to capacitor bank application, is not effective. In case of full compensation transient states of load disconnection may cause danger overvoltage. Therefore such compensation is very limited and still large amount of lagging power is demanded. Developed compensator, based on DC/AC three level power electronic converter, delivers stepless leading reactive power. Control system provides precise values of produced three phase sinusoidal leading current and then the generation system produces only active power. Simulation and laboratory tests confirm high dynamics of reactive power controller and full compensation in steady state.
PL
Przedstawiono model polowo-obwodowy autonomicznej prądnicy asynchronicznej w wzbudzeniu kondensatorowym. Model zastosowano do kształtowania charakterystyk prądnicy asynchronicznej poprzez wpływ na długość pakietu blach wirnika oraz liczbę uzwojenia stojana.
EN
Field - circuit model of the autonomous asynchronous generator with capacitor excitations is presented. This model is applied for characteristics forming of the asynchronous generator by means of influence on a rotor magnetic core lenght and on a stator winding turns number.
20
60%
EN
We have formed an approach to the creation of autonomous sources of energy supply to improve the reliability of power supply systems. We have proposed the solutions to energy supply systems enabling the decrease of influence of the unfavorable coincidence of climatic conditions or anthropogenic circumstances. The proposed solutions improve the conventional energy supply systems of the critical purpose objects. We have presented the principles of forming the local autonomous sources of energy supply, created in non-steady situations and completed with regular electric equipment that is in constant production operation at local enterprises or establishments. We have determined the limits for the stable operation of local autonomous sources of energy supply at the connection of typical consumers of electric power.
PL
Zaproponowaliśmy podejście do tworzenia autonomicznych źródeł zaopatrzenia w energię w celu poprawy niezawodności systemów zasilania. Zaproponowaliśmy rozwiązania systemów zasilania w energię, które pozwalają na zmniejszenie wpływu niekorzystnej zbieżności warunków klimatycznych lub warunków antropogenicznych. Proponowane rozwiązania poprawiają konwencjonalne systemy zasilania energią obiektów o znaczeniu krytycznym. Zaprezentowaliśmy zasady tworzenia lokalnych autonomicznych źródeł zaopatrzenia w energię, stworzonych w niestabilnych sytuacjach i zbudowanych z klasycznego wyposażenia elektrycznego, które jest w ciągłej produkcji w lokalnych przedsiębiorstwach lub zakładach. Ustaliliśmy limity dla stabilnego funkcjonowania lokalnych autonomicznych źródeł zaopatrzenia w energię przy podłączeniu typowych odbiorców energii elektrycznej.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.