Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  flow sensor
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this work a simple new type of flow sensors was developed; the double coil flow sensor. In this sensor two coils are magnetically coupled due to the flow of pure water inside them. The first coil, the primary coil, was supplied by AC voltage in the frequency range 0.5-1 MHz which is the coupling range of frequency for water. The voltage in the second coil, was found to be directly proportional with the volumetric flow rate of the water flowing inside the coils. The two coils can only be coupled in the laminar flow region. In the turbulent region, due to the turbulent chaos and fluctuation the two coils cannot be effectively coupled, and therefore the sensor cannot be used. The temperature of the water was found to have a negligible effect on the coupling, which add a good advantage to the simplicity of the double coil sensor. The working fluid used in this work was pure water. Other fluids are believed to be working as well, most probably at different frequency range, and this will be the subject of future work.
2
Content available remote Numeryczne modelowanie mikrozwężkowego czujnika przepływu
86%
PL
Przedstawiono wybrane wyniki modelowania numerycznego podwójnej mikrozwężki stosowanej jako czujnik przepływu, dla modeli turbulencji k-ω oraz k-ε i porównano wyniki wzorcowego modelu mikrozwężki z wynikami uzyskanymi doświadczalnie. Zamieszczona charakterystyka mikrozwężki (wzmocnienie mikrozwężki w zależności od prędkości napływającego strumienia) wskazuje, że wyniki symulacyjnych badań z zastosowaniem modelu k-ω pokrywają się z wynikami uzyskanymi doświadczalnie.
EN
In the paper simulation results of double Pitot-Venturi tube based on program packed Fluent 6.2 with k-ω and k-ε turbulence model were compared with the results of the experiment. The diagram of the double Pitot-Venturi tube (amplification coefficient was calculated from stream velocity) indicated that the result of the simulation with k-ω turbulence model are adequate to the results of the experiment.
EN
This work shows how a single coil wrapped on a pipe can be used to measure the volumetric flow rate inside the pipe and how by wrapping a second coil the flow direction can be detected. The developed method is very simple, accurate, and cover all the range of flow from low speed to high speed with more accuracy expected at high speed. Few turns are sufficient for the coils, no calibration is needed, and the method can be used for all kinds of nonmagnetic fluids even, with less accuracy, without the need to know the type of fluid inside the pipe. The principle of the developed method is theoretically explained and proved and then experimentally validated.
PL
Nowe uregulowania prawne (Nowelizacja ustawy "Prawo o miarach" z dnia 27 maja 2004, która obowiązuje od 6 lipca 2004) stwarzają możliwości rozwoju dla nowych laboratoriów badawczych przepływu cieczy i wzorcowania przetworników przepływu. Przy niedostatecznej ilości akredytowanych laboratoriów badawczych przepływu cieczy wydaje się, że powiązanie wzorca strumienia cieczy z wzorcami masowymi (metoda wagowa pomiaru strumienia) nie powinno stanowić utrudnienia we wprowadzaniu modyfikacji do dotychczasowych metod pomiaru strumienia oraz we wprowadzaniu wzorców opartych na innych metodach pomiaru, pod warunkiem, że będą one spełniać wymagania metrologiczne dotychczasowych masowych wzorców strumienia.
5
Content available remote Flow through sensor for the chemiluminescence determination of thiamine
72%
EN
A novel chemiluminescence (CL) sensor for thiamine combined flow-injection (FI) technology is presented in this paper. The analytical reagents, luminol and ferricyanide, were both immobilized on an anion exchange column. The CL signal produced by the reaction between luminol and ferricyanide, which were eluted from the column with the sodium phosphate injection, was decreased in the presence of thiamine. The decreased CL intensity was linear for thiamine concentration in the range from 0.2 to 4.0 nmol mL(-1); and the limit of detection was 66 pmol mL(-1) (3sigma). The whole process, including sampling and washing, could be completed in 2 min with a relative standard deviation of less than 3.0%. The sensor could be reused more than 400 times and has been applied for the determination of thiamine in pharmaceutical preparations and human urine samples.
PL
Opracowano nowy sensor do oznaczania tiaminy w przepływie oparty napomiarze chemiluminescencji (CL). Reagenty: luminol, heksacjanożelazian(III) potasu sąpoczątkowo związane na kolumnie anionowymiennej. Po wymyciu reagentów z kolumny wstrzykiwanym fosforanem sodu, w wyniku reakcji pomiędzy luminolem i heksacjanożelazianem powstaje sygnał CL, który w obecności tiaminy jest osłabiony. Zmiana sygnału CL jest proporcjonalna do stężenia tiaminy w zakresie od 0.02 do 4 nmol mL(-1). Granica wykrywalności, liczona jako 3-krotne odchylenie standardowe, wynosi 66 pmol mL(-1). Cały proces analityczny można wykonać w 2 min, a sensor może być użyty przynajmniej 400 razy. Opracowany sensor został zastosowany do oznaczania tiaminy w preparatach farmaceutycznych i w moczu.
PL
Opisano przebieg badań nad opracowaniem technologii spawania laserem Nd:YAG elementów pomiarowych sondy piętrzącej czujnika przepływu. Dobrano parametry procesu spawania laserowego umożliwiające sprostanie wysokim wymaganiom jakościowym spoin, w szczególności co do estetyki połączeń oraz precyzji ułożenia spoiny bez naruszenia ścianki wewnętrznej cienkościennych rurek pomiarowych. Omówiono wpływ technologii spawania na odkształcenia elementów po spawaniu oraz przedstawiono wyniki badań wytrzymałościowych uzyskanych połączeń. Wykonane partie prototypowe czujników przepływu z elementami pomiarowymi o długości od ok. 400 mm do 1700 mm, spawanymi laserem pracują obecnie na rurociągach przesyłowych.
EN
It has been described the course of investigations on development of technology of Nd:YAG laser welding of the probe measuring elements in flow sensors. The investigations were focussed on the selection of welding process parameters enabling to meet high quality requirements, especially as to the aesthetic appearance of welds and precision bead formation without any disturbance of the internal surface of thin-walled measuring tubes. The influence of welding technology on welding distortions has been discussed and the results of mechanical testing of welded joints have been presented. Laser welded prototype series of flow sensors with measuring elements from about 400 mm up to 1700 mm in length are used at present on pipelines.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.