Danfoss Drives A/S has developed a 1,2MVA Active Front End (AFE). The purpose was to realize a high power AFE as a study object. The AFE was integrated into a new dynamometer and engaged in testing of high power motor inverters. Because of limited time frames the design had to assure immediate successful operation. That was the reason that standard inverter modules have been used. The article presents the crucial problems we had to cope with when developing the AFE project. Based on the gained experience a few 1,2MVA converters with AFE solution were built and commissioned at the container gantry cranes in a harbour in Africa.
2
Content available remote Control of Voltage Source Inverter with an LCL Filter without Voltage Sensors
88%
EN
The voltage source inverter with LCL filter has to adopt damping method to suppress the resonance of LCL filter, which increases of losses and sensors. With virtual flux estimation idea, grid voltage-sensor-less technology is applied to design observers for the grid voltage, capacitor voltage and current. The observed grid voltage and capacitor voltage is used to realize voltage orientation control and grid current compensation for unit power factor. The observed capacitor current was fed forward to restrain LCL response and keep the control stable. The simulation results verify the correctness of observes design and the control method.
PL
W artykule analizuje się przekształtnik o źródle napięciowym VSI z filtrem LCL w zastosowaniu do sieci elektrowni wiatrowych. Analizę przeprowadza się na podstawie monitorowania napięcia sieci, prądu sieci i napięcia na kondensatorze.
PL
Artykuł przedstawia właściwości układu przekształtnika sieciowego z filtrem typu LCL z wykorzystaniem sprzężenia od wspólnego pomiaru prądu cewek filtru. Przedstawiono analizę porównawczą układów wykorzystujących sprzężenie od pojedynczego prądu jednej bądź drugiej cewki filtru LCL oraz możliwości poprawy odpowiedzi na wymuszenie prądu zadanego w układzie ze sprzężeniem zawierającym wyłącznie człon proporcjonalny. Przedstawiono wyniki symulacji i eksperymentu potwierdzającego pewne korzystne cechy wykorzystania wspólnego czujnika prądu.
EN
The paper presents properties of grid converter with LCL filter utilizing a common measurement and feedback of filter inductors currents. Comparative analysis of single inductor current feedback (inverter side or grid side inductor of LCL filter) and improvement of response on reference current change using only proportional term in the feedback loop are presented. Simulation and experimental tests results confirming some positive features of single current measurement of both inductors currents are shown.
EN
This paper presents the averaged and switching function modelling for the active power filter (APF) with LCL-type coupling impedance. The mathematical model of the LCL-type APF is derived using switching function modelling technique, followed by the Fourier series analysis of the switching functions. The equivalent circuits are presented from the averaged and switching ripple model. The presented technique is also extended to the analysis of the modulation signal and inverter dc-link voltage. Finally, the experimental results are presented for verification.
PL
Artykuł prezentuje modelowanie uśredniającej i przełączającej funkcji aktywnego filtru z impedancja sprzęgającą typu LCL. Model matematyczny jest wyprowadzony przy modelowaniu funkcji przełączającej a następnie przez analizę Fouriera tej funkcji. Zaprezentowano schemat zastępczy. Przedstawiona technika może być rozszerzona do analizy sygnału modulowanego i przekształtnika. Na zakończenie przedstawiono wyniki eksperymentów.
PL
W artykule przedstawiono topologię oraz algorytm sterowania pięciopoziomowego przekształtnika AC-DC przeznaczonego do współpracy z siecią trakcyjną 3 kV DC. W przekształtniku zaimplementowana została metoda sterowania VOC (Voltage Oriented Control) z predykcyjnym regulatorem prądu sieci elektroenergetycznej oraz z algorytmem minimalizacji negatywnego wpływu występowania napięcia zaburzeń wspólnych. Na końcu opracowania przedstawione zostały wyniki badań symulacyjnych układu w środowisku Matlab/Simulink.
EN
This paper presents the topology and the control algorithm of five-level, 3 kV DC, traction AC-DC converter. The VOC (Voltage Oriented Control) method with FCS-MPC (Finite Control Set – Model Predictive Control) grid current regulator has been implemented for the converter. The control algorithm has been also extended with the common-mode voltage suppression component. Last part of this paper presents simulation results and findings of the implemented algorithms in Matlab/Simulink software.