Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 42

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electrocardiography
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
EN
The inverse electrocardiography was under development for many years. In this novel approach one application was elaborated and described in this paper; with 3D real–time visualisation of ECG tracings on a PC. Using the electrocardiography data–stream from the chest leads, electrical excitation sequence was visualised — by the non–invasive technique, supported by the three–dimensional model of heart.
2
Content available remote Visualization and simulation of the human heart based on ECG
100%
EN
The aim of this study was to develop a three-dimensional (3D) animation of the heart that can show its components and function using electrocardiography. Another aim of the study was to increase knowledge on computer graphics and animation as well as to create a useful educational tool that, through play, will also teach. Because the heart is one of the most important organs and a very complex one, the authors decided to create a 3D model. This article presents the current state of knowledge in the use of computer-generated models of the human heart as a learning aid and for creating simulation. The authors describe the tools used to implement the program and sources that were used for modeling the heart. The result is presented in the form of descriptions and screenshots on how to use the program. At the end of the article, a description is placed of further developments that will be applied to the program.
EN
The significant progress in the treatment of non-Hodgkin lymphomas, translating into prolongation of overall survival results in the manifestation of long-term adverse events, like anthracycline-related cardiotoxicity. Despite the dose-dependent cardiac dysfunction and the presence of risk factors, the increasing probability of cardiotoxicity arises from individual predisposition. Identification of high- -risk patients gives the opportunity to implement the prevention strategies to reduce the incidence of cardiac complications. The study evaluated the utility of biomarkers: N-terminal B-type natriuretic peptide, troponin I and electrocardiography with spatial QRS-T angle assessment, as indicators of individual sensitivity of cardiomyocytes to doxorubicin resulting in myocardial damage. Thirty-five treatment-naïve patients at increased risk of cardiotoxicity, were subjected prospectively during (R)-CHOP treatment to echocardiographic assessment and analysis of biomarkers: TnI and NT-proBNP plasma level and spatial QRS-T assessment before and 24 hours after each cycle of chemotherapy. The analysis of QRS-T angle was consistent with the results of NT-proBNP assessment and allowed to identify, after the first cycle of chemotherapy, patients at increased risk of developing cardiovascular complications, who require thorough echocardiographic analysis and primary cardioprotection implementation. Our data did not reveal the role of TnI in the identification of cardiac events. Our findings, though promising, should be confirmed in a larger group of patients in real-life or clinical trials.
5
Content available remote The computer model of heart electrical activity
75%
EN
The paper describes principles of the two-dimensional computer model of the heart's electrical potential activity based on formalism, created for the cell membrane by Hodgkin and Huxley. The main equations have been shown, and all kinds of heart cells involved in simulation have been considered. The method of obtaining ECG from the model was discussed together with ECG examples obtained from the computer simulations. A comparison of computer simulated and the real ECG for the atrioventricular block has been made. As an example of application, a set of simulation of heart muscIe responses on the external disturbance formed in the impulse have been presented.
EN
The frequency and nature of electrocardiographic changes in patients with pulmonary hypertension varies significantly depending on the severity of the illness. In mild cases, electrocardiogram (ECG) may be normal. We present the consecutive ECGs of a patient with pulmonary arterial hypertension (PAH) in the 5-year course of the disease – from diagnosis to lung transplantation. The described case shows the variability of ECG changes in correlation with the clinical state of the patient. The observed ECG abnormalities in PAH are reversible and in the presented case ECG normalized after lung transplantation.
PL
Częstość i charakter zmian w zapisach elektrokardiograficznych u pacjentów z nadciśnieniem płucnym zna-cząco różni się zależnie od ciężkości choroby. U pacjentów z łagodnym nadciśnieniem płucnym zapis elektro-kardiograficzny (EKG) może być prawidłowy. W niniejszej pracy prezentujemy kolejne zapisy EKG pacjentki z tętniczym nadciśnieniem płucnym (pulmonary arterial hypertension – PAH) w 5-letnim okresie choroby – od postawienia diagnozy aż do przeszczepienia płuc. Opisany przypadek pokazuje różnorodność zmian w zapi-sach EKG, których nasilenie korelowało ze stanem klinicznym pacjentki. Obserwowane nieprawidłowości w zapisach EKG w przypadku PAH są odwracalne i w prezentowanym przypadku doszło do ich normalizacji po przeszczepieniu płuc.
7
Content available remote Mathematical models of electro- and magnetocardiographic processes
75%
EN
The paper offers mathematical models of electro- and magneto-cardiographic processes developed on the basis of steady regimes’ analysis of sophisticated electric and magnetic circuits. The conducting heart system is represented by either voltage or current sources whose parameters were received from analysis of transient processes in electric parametric circuits with distributed parameters.
PL
Praca przedstawia modele matematyczne procesów elektrokardiograficznych wykorzystujące stany ustalone w obwodach elektrycznych i magnetycznych. System elektryczny przewodnictwa w sercu jest reprezentowany przez źródła napięcia lub prądu oraz pojemności i rezystancje (wszystkie o charakterze rozłożonym). Opis takiego systemu odpowiada równaniom telegrafistów.
EN
The paper presents an instrumentation set for effective diagnostics of early symptoms of fetal distress in high-risk pregnancy based on bioelectric signals recording. The representative database of records has been established that enabled the complex analysis of signals recorded on a surface of maternal abdomen. As an outcome, the effective algorithms have been developed for processing both the fetal electrocardiogram and the signal of electrical activity of a uterine muscle. This allowed the development of unique diagnostic system based on external biosignal measurement module connected to the standard personal computer. In this system, like in a classical fetal monitor, the fetal heart rate (FHR) signal together with contraction activity signal of uterine muscle and fetal movement become an essential source of information on fetal condition. In addition, there is a possibility for spectral analysis of FHR signal as well as a morphology assessment of fetal ECG signal.
EN
The aim of this study was to establish the physiological ECG values in the Silesian horse and to compare the results with literature data for other breeds of horses. This study was carried out on 31 healthy Silesian horses (15 males and 16 females) aged 2-19 years. The ECG was carried out after an anamnesis and clinical examination and without prior premedication or use of force, both of which could affect the ECG result. The mean heart rate (HR) in the Silesian horses was 39 ± 8.1 beats per minute. In the majority of the leads, P waves were single positive waves. Notched waves were present in 16-51% of the horses, bifid waves were found less frequently, and biphasic P waves were seen least frequently. In the aVR lead, the P wave was most commonly found to be single negative. The PQ interval ranged from 0.18 s in the CV1 lead to 0.29 s in the aVR lead. Most often, the PQ interval lasted 0.24-0.28 s. The QRS duration ranged from 0.079 s in the CV1 lead to 0.099 s in lead III. The QRS duration was between 0.08 and 0.1 s. Generally, the T wave was single positive or negative. It was biphasic only in the precordial leads. Unlike P waves, notched T waves were not found. The ECG parameters in the Silesian horse do not differ from normal ECG values for other horse breeds of similar weight. Specific features of the ECG in the Silesian horse are a frequent occurrence of additional R’ and S’ waves in the Einthoven leads and a relatively long supraventricular conduction time.
PL
W celu wdrożenia elementów systemu telemedycznego związanego z diagnostyką [3], konieczne jest wcześniejsze zweryfikowanie wartości diagnostycznej algorytmów decyzyjnych odpowiedzialnych za wykrywanie stanów zagrożenia życia. Analiza przebiegu EKG jest w stanie dać informację o wielu takich stanach związanych z zaburzeniami układu krążenia [8]. W tym celu konieczne jest podjęcie szeregu działań prowadzących do budowy odpowiednich modeli. Pierwszym krokiem jest filtracja i przygotowanie danych [1], następnie ekstrakcja parametrów z przebiegów EKG, analiza wyników, porównanie ich z posiadanymi modelami oraz postawienie diagnozy. Każdy z tych kroków wymaga zastosowania odpowiedniego podejścia w celu zminimalizowania popełnianego błędu [4], wynikającego z niekiedy znacznie zniekształconego sygnału [7]. W celu ekstrakcji parametrów czasowych z odfiltrowanego i przygotowanego sygnału EKG konieczne jest najpierw wykrycie załomka R w zespole QRS [6], następnie wyznaczenie załomków P, Q, S, T i znalezienie ich początku i końca oraz określenie interesujących nas interwałów [2]. Zaproponowana tutaj metoda bazuje na aproksymacji przebiegu w oknie czasowym zawierającym dany załomek wielomianem określonego rzędu. Takie podejście pozwala następnie na wyznaczenie punktów przegięcia i, co za tym idzie, granic załomka. Metoda została zastosowana do przetwarzania przebiegów zarejestrowanych w warunkach laboratoryjnych w spoczynku i w trakcie kontrolowanego wysiłku, wyniki zostały porównane i przedstawione w niniejszej pracy.
EN
To succesfully implement a telemedical system for diagnostic purposes it is necessary to verify the diagnostic value of the decision algorithms used to detect life threatening situations. ECG analysis is a useful tool for obtaining information about the overall patient condition, especially for the circulatory system. Proper recognition cannot be performed without creation of proper models, The first step is signal filtration and data preparation, followed by parameter extraction, comparison with the model and diagnosis presentation. Each of these steps reqires a certain approach to minimize the error. Proper filtration needs to be performed. Then, the QRS complex is detected and rythm is calculated. Afterwards, the remaining waves are detected. To be able to perform valuable time dependencies it is necessary to exactly mark the beginnings and ends of intervals. The proposed method is based on opproximating the signal around the wave with a polynomial of a certain degree. This allows detection of inflection points corresponding to the borders of the wave. The method was applied to a set of ECG signals recorced during rest and activity, the results are presented and discussed.
EN
A method for automatic signal analysis and signal averaging of multichannel electric or magnetic heart signals is proposed. The method is based on the calculation of a matrix of similarity between all ventricular complexes in the multichannel signal. This similarity matrix is used to group the heart beats into different clusters. The temporal alignment of heart beat signals belonging to one cluster is optimized for signal averaging. The similarity matrix contains also useful informations about physiological processes that alter the pattern of the heart activation. Various applications of the method are described.
PL
W pracy zaproponowano metodę automatycznej analizy i uśredniania wielokanałowych sygnałów czynności elektrycznej lub magnetycznej serca. Metoda jest oparta na wyznaczeniu tablicy współczynników określających podobieństwo między wszystkimi zespołami QRS, opisującymi czynność elektryczną komór, w sygnale wielokanałowym. Tablica podobieństwa jest wykorzystywana do grupowania cykli serca w osobne klasy. Przed uśrednianiem sygnałów jest optymalizowane czasowe położenie cykli serca należących do jednej klasy. Tablica podobieństwa zawiera również użyteczne informacje o fizjologicznych procesach, które zmieniają wzorzec aktywacji serca. W pracy przedstawiono także różne zastosowania opisanej metody.
12
Content available remote Arrhythmia vulnerability evaluation in the BioMag laboratory
75%
EN
In this paper, an approaeh taken in the BioMag Laboratory in Helsinki University Central Hospital for non-invasive deteetion of patients at risk for malignant arrhythmias is deseribed. The multichannel high-resolution magnetoand eleetroeardiographic instrumentation and other facilities of the BioMag Laboratory are introdueed. The different methods implemented to deteet arrhythmogeneity and repolarization as wen as autonomie nervous system, are presented, and examples of applieation to patient data are given.
PL
W artykule opisano metodę nieinwazyjnej identyfikacji pacjentów zagrożonych groźnymi zaburzeniami rytmu serca wykorzystywaną w Laboratorium BioMag w University Central Hospital w Helsinkach. Przedstawiono aparaturę do pomiarów magneto i elektro-kardiograficznych o wysokiej rozdzielczości oraz inne wyposażenie laboratorium BioM ag. Opisano różne metody wykorzystywane do wykrywania w kardiogramach cech wskazujących na źródła arytmii, obejmujące analizę depolarayzacji i repolaryzacji komór jak również autonomicznego układu nerwowego oraz pokazano przykłady zastosowania tych metod li pacjentów.
13
Content available remote Vortex currents detected by stress MCGand fragmentation of ECG /MCG in VT patients
75%
EN
The information content of electrocardiogram (ECG) and magnetocardiogram (MCG) is different. This is demonstrated by an investigation of the dependence of the signals on heart rate changes after physical exercise. For healthy volunteers the repolarization changes drastically in the MCG whereas no comparable changes are found in the ECG. A beat-to-beat analysis shows that in some cases an alternating T-wave is observed in the stress-MCG of healthy volunteers. The diagnostic value of both ECG and MCG for identifying patients at risk of ventricular tachycardia is demonstrated in three studies focusing on the depolarization phase of the signal.
PL
Informacja jaką zawiera elektrokardiogram (EKG) i magnetokardiogram (MKG) jest różna. Zostało to wykazane w badaniach zależności sygnałów od zmian częstości rytmu serca po wysiłku fizycznym. U zdrowych ochotników repolaryzacja zmienia się drastycznie w zapisie MKG, podczas gdy nie zostały znalezione porównywalne zmiany w EKG. Analiza beat-to-beat wykazuje, że w niektórych przypadkach obserwuje się zmieniony załamek T w wysiłkowym MKG u zdrowego ochotnika. Na podstawie trzech badań skupiających się na fazie depolaryzacji sygnału oszacowano wartość diagnostyczną zarówno EKG jak i MKG dla identyfikacji pacjentów zagrożonych częstoskurczem komorowym.
14
Content available remote Mathematical modelling of the thorax and the heart
75%
EN
The paper presents a short overviev of the presents stste in computer modelling of the heart and the thorax. Source models and numerical techniques to solve the forward and inverse problems of magneto-and electrocardiography are described. In addition, accurate integration of the inverse solutions with the heart anatomy is discussed.
PL
Artykuł przedstawia krótki przegląd obecnego stanu badań komputerowego modelowania serca i klatki piersiowej. Opisano źródła modeli oraz techniki numeryczne do rozwiązywania problemów forward i inverse w magnetokardiografii i elektrokardiografii. Ponadto omówiono dokładne integrowanie rozwiązania (invers solution) z anatomią serca.
15
Content available remote Electromagnetism of the heart
75%
EN
Health care is today favoring the use of noninvasive, or at least minimally invasive methods. This trend emphasizes the role of various medical imaging methods. The combination of the noninvasive bioelectromagnetic measurements with other medical imaging methods is a very powerful research tool for functional studies of the heart, both in basic research anel in clinical applications. The bioelectromagnetic fields are produced by the bioelectric activity of the human tissue. Thus no illumination with electromagnetic radiation is needed, and the measurements are totally noninvasive. Recently, the measurement and interpretation of data from the electric body surface potential mappings, as well as from magnetic field mappings has been of increasing interest. Although the methods are useful for clinical applications as well, they still have to be developed for more easy and reliable use. For instance, more advanced methods for data processing and analysis are still needed.
PL
Współczesna ochrona zdrowia preferuje stosowanie nieinwazyjnych lub przynajmniej minimalnie inwazyjnych metod. Ten trend wzmacnia pozycję wielu różnorodnych metod obrazowania w medycynie. Kombinacja nieinwazyjnych pomiarów bioelektromagnetycznych z innymi metodami obrazowania medycznego jest bardzo wydajnym narzędziem badawczym w badaniach funkcjonalnych serca, zarówno w badaniach podstawowych, jak i w zastosowaniach klinicznych. Pola bioelektromagnetyczne są wytwarzane przez aktywność bioelektryczną ludzkich tkanek. Dlatego nie jest potrzebne naświetlanie za pomocą promieniowania elektromagnetycznego, a pomiary są całkowicie nieinwazyjne. Ostatnio wzrasta zainteresowanie pomiarami i interpretacją danych uzyskanych z mappingu potencjałów elektrycznych z powierzchni ludzkiego ciała, jak również z mappingu pól magnetycznych. Chociaż metody są użyteczne również w zastosowaniach klinicznych, muszą one być wciąż rozwijane, aby ich wykorzystanie było łatwiejsze i bardziej wiarygodne. Na przykład wciąż są potrzebne bardziej zaawansowane metody przetwarzania i analizy danych.
PL
W artykule przedstawiono metodykę postępowania przy projektowaniu algorytmu przeznaczonego do lokalizacji zespołów QRS w zapisie EKG. Omawiane zagadnienie stanowi podstawowy etap, wspomaganej komputerowo automatycznej analizy zapisów EKG. Dokładność określania pozycji zespołów QRS ma bardzo duże znaczenie gdyż bezpośrednio wpływa na diagnostyczną wartość wyznaczanych, podstawowych parametrów pracy serca, a także na jakość danych otrzymywanych na dalszych etapach analizy zapisów EKG.
EN
The article concerns automatic QRS-complex detection in the ECG signal. The presented algorithm is the modified variant of the one worked out by Li C. et al. The presented algorithm is characterized by the sensitivity Se = 99.87% and Positive predictivity value P+ = 99,92% The advantage of the author’s solution is that the maximum detection error rate for “the worst” signal is much smaller for the presented algorithm (1.14%) as referred to the reference one (1.59%).
EN
In this paper a concept of finite impulse response (FIR) narrow band-stop (notch) filter with non-zero initial conditions, based on infinite impulse response (IIR) prototype filter, is proposed. The filter described in this paper is used to suppress power line noise from ECG signals. In order to reduce the transient response of the proposed FIR notch filter, optimal initial conditions for the filter have been determined. The algorithm for finding the length of the initial conditions vector is presented. The proposed values of the length of initial conditions vector, for several ECG signals and interfering frequencies, are calculated. The proposed filters are tested using various ECG signals. Computer simulations demonstrate that the proposed FIR filters outperform traditional FIR filters with initial conditions set to zero.
EN
Time-frequency template matching ECG compression algorithm has an outstanding compression effectiveness and very low distortion of medical data content. Its main disadvantage is the presence of spare patterns as a consequence of poor pattern-to-signal synchronization. This issue is investigated in detail in this paper, and possible solutions are derived: P-onset, QRS-onset and R-max synchronization points are used. Finally these three methods are compared with use of the same data set in order to minimize the number of templates created. Results may be interesting to a wide range of scientist working on a time-frequency representation of a heart’s beat, since it gives several considerations on the representation stability.
EN
Time-frequency domain compression of an ECG is the new still underestimated issue. This paper is devoted to the statistical analysis of the ECG dynamic ranges on various aspects of time-frequency plane. The traditional approach to the signal values distribution, originally introduced by Huffman, is now studied for integer time-frequency coefficients obtained with use of reversible integer-to-integer wavelet transform. Obtained results determine limits of perfectly lossless compression ratios for an electrocardiogram. They are interesting for comparative purposes and further development of nearly lossless algorithms. The research had initially only experimental aims, but practical hardware implementation is also feasible.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.