Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electric potential
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents the results of experiments with electroflotation beneficiation of gold-bearing raw materials. Three variants of ore samples with 0.56, 1.2 and 5.9 g/t gold grades, which also have different mineralogical and phase composition, were taken as objects of study. Based on the ionization effects, as well as changes in electrostatic and electrokinetic properties of the flotation pulp components, different electrode locations in the flotation chamber were considered. Experiments have shown that for electroflotation processing of raw materials with weakly acidic and neutral medium, positive electric potential of pulp, as well as raw materials with complex mineralogical composition, the negative electrode (cathode) should be placed at the surface of foaming and concentrate assembly, and the positive electrode (anode) in the pulp flow. For electroflotation of raw materials with neutral, alkaline pH and negative electric potential of the pulp, the anode is placed at the surface of the concentrate formation and the cathode is placed in the pulp flow. Thus, additional electrolytic treatment of mineral slurry in the flotation process can increase the gold recovery in the flotation concentrate by an average of 20–30%.
EN
The present investigation deals with the study of Green’s functions in orthotropic piezothermoelastic diffusion media. With this objective, firstly the two-dimensional general solution in orthotropic piezothermoelastic diffusion media is derived. On the basis of general solution, the Green function for a point heat source and chemical potential source in the interior of semi-infinite orthotropic piezothermoelastic diffusion material is constructed by five newly introduced harmonic functions. The components of displacement, stress, electric displacement, electric potential, temperature change and chemical potential are expressed in terms of elementary functions. Since all the components are expressed in terms of elementary functions, this fact makes them convenient to use. From the present investigation, a special case of interest is also analyzed to depict the effect of diffusion. Resulting quantities are computed numerically and presented graphically to illustrate the effect of diffusion.
PL
W pracy omówiono wyniki badań strefy oddziaływania materiału konstrukcyjnego na środowisko - hydrorafinat II. Ustalono, że w warunkach ruchu elementu względem środowiska, materiał wykazuje własny potencjał powierzchniowy. Potencjał powierzchniowy elementu określa rodzaj materiału warstwy powłokowej. Potencjał stacjonarny materiałów powłokowych jest bliski wyższemu stopniowi utlenienia metalu kontaktującego się z olejem (Cu+2, Zn+2, Ag+1, Ni+3, Sn+4). Pomiary potencjałów elektrycznych materiałów konstrukcyjnych w oleju bazowym umożliwią komputerowe sterowanie powierzchniowymi przemianami fazowymi w środowisku hydrorafinatu II po uszlachetnieniu jego składu chemicznego.
EN
In this work the results of the impact zone of the construction material on the environment (hydroraffinate II) are discussed . It was found that in conditions of relative movement according to the environment, the material has its own surface potential. The surface potential of the rotating element is specified by the coating layer. The potential of the stationary coating materials is close to a higher degree of the oxidation of metal which is combined with oil (Cu+2, Zn+2, Ag+1, Ni+3, Sn+4). The possibility of measurement of electrical potentials of structural materials in the base oil will allow computer controlling of the surface phase changes in the environment of hydroraffinate after the process of their chemical composition.
EN
The development of a diagnostic system is a complex engineering problem aimed at preventing damage caused by deteriorating properties of the materials and structures. This article presents the method of nondestructive testing of change control of concrete structures. The analysis of literature data shows that the overwhelming majority of studies are devoted to the change in electrical resistance of concrete in the collection of its strength, and practically no analogous studies regarding its aging are presented. Theoretical substantiation of the change in electrical concrete characteristics (conductivity, resistance) is given with a change in its strength. A work over-bridge in operation more than 30 years has been surveyed. The experimental part consisted in measuring the electrical potentials on the bridge structures, as well as in determining the strength of the material at the same points. Correlation dependence between the measured electric potential value and the strength of the samples taken from the bridge structures were obtained.
|
2023
|
tom Vol. 24, No. 1
art. no. 2023109
EN
The main insulation layer is the most important layer of the high-voltage cable, and the quality of this material directly affects the life of the cable. It is also known that contamination, porosity and associated partial discharges in the insulation can affect the service life of cables. In this paper, we use the COMSOL Multiphysics software, which is based on the finite element method in AC/DC, 2D electrostatic. Our study shows the effect of heterogeneous cavities on the functioning of electrical cables. This work contains the study of electric field distribution and potential of a model of high voltage cable; we took into account the absence and the presence of heterogeneous cavities. The study was conducted using numerical results with mathematical validation. The obtained results are considered satisfactory, favorable and very promising.
PL
W urządzeniach mechanicznych zabezpieczenie antykorozyjne oraz wymagane właściwości tribologiczne elementów wykonanych ze stali uzyskiwane są poprzez zanurzenie w środowisku dielektrycznym lub nałożenie warstwy smarowej. W pracy omówiono aktywność stali C45 z elektrolitycznie osadzonymi powłokami w środowisku o właściwościach dielektrycznych (hydrorafinacie II). Wykładnikiem aktywności tworzywa metalicznego jest napięcie elektryczne mierzone względem elektrody porównawczej. Podczas współpracy elementów uaktywnia się część powierzchni poddanej procesowi tarcia. Dla dwóch współpracujących pierścieni jest to obszar ich powierzchni bocznej. Pozostała powierzchnia pierścienia wykazuje potencjał wyjściowy. Wstępnie utleniona powierzchnia powłoki podczas procesu tribologicznego jest usuwana i odkrywa rdzeń powłoki. Uaktywnienie rdzenia powłoki pozwala na konstytuowanie procesów chemicznych (wymiany) i elektrochemicznych.
EN
The protection of corrosion in mechanical devices and tribological properties of steel components, which are required, is achieved either through the immersion in the dielectric environment or through applying a grease layer. The activity of C45 steel with electrolytically embedded coatings in the environment of dielectric properties (hydrorafinat II) is described in this work. The exponent of the metal material activity is the electric voltage, which is measured relative to the reference electrode. During the cooperation of the elements, the activated surface is subjected to the process of friction. For the two rings, this is the area of their lateral surface. The rest of the surface of the ring has initial potential. During the tribological process, the oxidised surface of the coating is removed revealing its core. The process of the activation of the core of the coating allows the creation of the chemical processes (exchange) and electrochemical processes.
7
Content available remote Rozkład ładunku na przewodzącej elipsoidzie
72%
PL
Przedstawiono sposób uzyskania dokładnego wzoru na rozkład gęstości powierzchniowej ładunku na różnoosiowej elipsoidzie przewodzącej.
EN
Method calculating of distribution surface charge density on the conducting ellipsoid.
8
Content available remote Zjawiska elektryczne w kościach długich
72%
PL
W pracy przedstawiono potencjały elektryczne obserwowane w kościach długich podczas ich odkształcania w zakresie sprężystym pod wpływem fizjologicznych obciążeń. Zaprezentowano próby teoretycznego wyjaśnienia mechanizmu ich generacji. Ponadto omówiono możliwości terapeutycznego zastosowania prądu elektrycznego w przypadku patologicznych złamań kości długich.
EN
The paper presents electrical potentials observed in long bones while their deformation in the elastic range caused by physiological loading. Theoretical explanation of the generation mechanism was presented. Furthermore, possible therapeutic applications of electric current in long bones treatment of pathological fractures were presented.
9
72%
PL
W artykule przedstawiono zastosowanie pochodnych ułamkowego rzędu do wyznaczania gradientu pola skalarnego, także przy zmianie układu współrzędnych. W naszych obliczeniach natężenie pola elektrycznego ładunku punktowego zostało wyznaczone na podstawie potencjału pola elektrycznego. Zbadano niektóre własności wyznaczonego gradientu.
EN
The paper presents the use of fractional-order derivatives for determining the scalar field gradient, also for the change of the coordinate system. In our calculations the electric field strength of the point charge was determined on the basis of the electric field potential. Some properties of the determined gradient were examined.
EN
Pole assignment for infinite many poles of the second order singular distributed parameter control system was discussed via functional analysis and operator theory in Hubert space. The solutions of the problem and the constructive expression of the solutions are given by the generalized inverse one of bounded linear operator. This research is theoretically important for studying the stabilization and asymptotic stability of the second order singular distributed parameter control system.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.