Odors are a mixture of volatile chemicals (organic and inorganic compounds), known as unpleasant gases which are perceptible even at low concentrations (low odor threshold). Chemicals which cause irritation of the mucous membranes of nose, throat and eyes through stimulation of the trigeminal nerve are among them. In some people psychosomatic symptoms occur as a result of exposure to odor. The sources of odors may be processes naturally occurring in nature (e.g. distribution of organic matter) and effects of human activities (sewage treatment plants, landfills, farms pigs). Emission of odors often goes beyond odor generating plants exposing the local population to their impact. Complaints of people motivate to create uniform criteria of smell and to study impact of odors on human health.
PL
Odory stanowią mieszaninę lotnych substancji chemicznych (organicznych i nieorganicznych), określanych jako złowonne gazy, które wyczuwalne są nawet przy niskich stężeniach (niskie progi wyczuwalności). Wśród nich znajdują się takie związki chemiczne, które poprzez stymulację nerwu trójdzielnego mogą powodować podrażnienia błon śluzowych nosa, gardła i oczu. U niektórych osób w wyniku ekspozycji na odory dochodzi do nasilenia objawów psychosomatycznych. Źródłem uciążliwych zapachów mogą być zarówno procesy zachodzące naturalnie w przyrodzie (np. rozkład materii organicznej), jak i wynikające z działalności człowieka (oczyszczalnie ścieków, składowiska odpadów, hodowle trzody chlewnej). Emisja odorów często wykracza poza teren tego typu zakładów, narażając na ich oddziaływanie lokalną ludność. Jej skargi motywują do prac mających na celu stworzenie jednolitych kryteriów zapachowych oraz skłaniają do badań nad wpływem nieprzyjemnych zapachów na zdrowie człowieka.
2
Content available remote Oddziaływania elektromagnetyczne zabawek
89%
|
2010
|
tom R. 86, nr 3
150-153
PL
Technologie elektroniczne i informatyczne są coraz częściej wykorzystywane w produkowanych zabawkach. Poniższy artykuł zawiera wyniki badań emisji elektromagnetycznej kilku zabawek mechanicznych zasilanych z baterii i sterowanych przewodowo oraz bezprzewodowo. Wraz z wynikami badań zaprezentowano odniesienie do wymagań obowiązujących norm bezpieczeństwa, ochrony środowiska i wymagań EMC.
EN
The development of electronic and computer technologies penetrates to the market of toys. The following article presents values of electromagnetic emission of several electro-mechanical toys (battery powered and remote controlled). The results of investigations were referred to the valid norms of safety, the protection of environment and the EMC requirements.
EN
INTRODUCTION In city agglomerations, educational establishments are very often within the vicinity of energy infrastructure such as, power lines, distribution transformers; power distribution rooms, mobile phone base stations and overhead tramway power lines. The levels of magnetic fi elds in the classrooms of such educational establishments are not well known. MATERIAL AND METHODS Ten primary schools from Tychy were chosen for the study, all of which are located within a radius of 100 meters from distribution transformers. The magnetic induction was measured in at least two classrooms, i.e. in the information technology classroom and a humanistics classroom. RESULTS Based on visual inspection, it was ascertained that for two schools, the transformers were installed at a distance of not more than 20 m. In one school the distance is 15 m and in another there was an aerial voltage line at a distance of 20 m. The latter school contained elevators. In the humanistics classroom adjacent to the elevator shaft, an induction level of 110 nT was measured. In one of the three oldest schools tested, which was 125 years old, the measured magnetic induction levels were even higher: in the humanistic classroom – 226 nT and in the computer studies classroom – 59 nT. We also found that for 10 schools, the magnetic induction levels were higher in the information technology classroom than in the humanistics classroom. CONCLUSIONS Transformers installed within the vicinity of school buildings do not infl uence the magnetic induction levels within classrooms and school premises.
PL
WSTĘP W aglomeracjach miejskich bardzo często placówki oświatowe zlokalizowane są w pobliżu infrastruktury energetycznej, takiej jak: przesyłowe linie energetyczne, stacje transformatorowe, rozdzielnie napięć, stacje bazowe telefonii komórkowej, sieci trakcji tramwajowej. Nie są znane poziomy pól magnetycznych w salach lekcyjnych tak usytuowanych budynków szkolnych. Celem podjętych badań była ocena poziomu indukcji magnetycznej w klasach i pracowniach budynków szkolnych usytuowanych w pobliżu stacji transformatorowo-rozdzielczych. MATERIAŁ I METODY Do badań wybrano 10 szkół podstawowych z terenu Tychów, w pobliżu których (w promieniu 100 metrów) zainstalowane były transformatory. Indukcję magnetyczną mierzono co najmniej w dwóch salach lekcyjnych (w pracowni informatycznej i pracowni do przedmiotów humanistycznych). WYNIKI Na podstawie przeprowadzonej wizji lokalnej stwierdzono, że tylko w dwóch szkołach transformatory energetyczne zainstalowane zostały w odległości nieprzekraczającej 20 m. W odległości 15 m od jednej ze szkół zainstalowany był transformator, a w odległości 20 m przebiegała napowietrzna linia elektryczna niskiego napięcia. W szkole tej, wewnątrz budynku, stwierdzono windę towarową. Zmierzony w sali humanistycznej sąsiadującej z tunelem windy poziom indukcji wynosił 110 nT. W jednej z trzech najstarszych badanych szkół (125-letniej) poziomy indukcji magnetycznej były jeszcze wyższe: w klasie humanistycznej 226 nT, a w pracowni informatycznej 59 nT. Wykazano ponadto, że w 6 spośród 10 zbadanych pracowni informatycznych poziomy indukcji magnetycznej były wyższe niż w klasach humanistycznych. WNIOSKI Transformatory zainstalowane w pobliżu budynków szkolnych nie miały wpływu na zmierzoną indukcję magnetyczną w klasach i pomieszczeniach szkolnych.
EN
INTRODUCTION There are various magnetic fi eld sources of unknown induction levels installed in schools. The aim of this research, is to evaluate level of magnetic induction in classrooms and workrooms of chosen schools in Katowice area. MATERIAL AND METHODS Magnetic induction measurements were taken in 10 primary schools, 12 middle schools and 4 secondary schools in Katowice area. Magnetic induction was measured in at least two classrooms i.e. in a computer science classroom and in a humanities subject classroom. Induction level was inspected by means of spot measurement. RESULTS In most schools, which were evaluated, magnetic induction level did not exceed 50 nT. Measurements taken in middle schools and secondary schools showed higher magnetic induction values in computer science classrooms in comparison to humanities subject classrooms. Mainly of year production and technical condition of installed computer equipment infl uenced magnetic induction level measured in computer science classrooms. Older computers generated higher levels of magnetic induction, in comparison to new equipment. In a part of one primary school, which was 120 years old, in humanities subject classrooms, measured magnetic induction was higher then 150 nT. In another primary school localized in highly industrialized area near coal mine, magnetic induction inspected in computer science classrooms was higher, then 400 nT, whereas induction level in humanities subject classrooms of this school oscillated around 100 nT. The highest levels of magnetic induction were measured in two schools, in which transformers were installed. The measured level of magnetic induction in one of the above mentioned schools was 200 nT. CONCLUSIONS Because diff erent magnetic induction levels are strictly related to the computer equipment type, the level of exposure of children and youth to magnetic induction should be evaluated, after installing the equipment.
PL
WSTĘP W budynkach szkolnych instalowane są różnego rodzaju źródła pól magnetycznych o nieznanych poziomach indukcji. Celem podjętych badań jest ocena poziomu indukcji magnetycznej w klasach i pracowniach szkolnych wybranych placówek oświatowych z terenu Katowic. MATERIAŁ I METODY Pomiary indukcji magnetycznej wykonano w 10 szkołach podstawowych, 12 gimnazjach i 4 liceach z terenu Katowic. Indukcja magnetyczna mierzona była w każdej szkole w co najmniej dwóch salach, tj. w pracowni informatycznej i pracowni do przedmiotów humanistycznych. WYNIKI W większości szkół poziom indukcji magnetycznej nie przekraczał 50 nT. Ujawniono wyższe wartości indukcji magnetycznej w pracowniach informatycznych w porównaniu do sal, w których odbywały się zajęcia z przedmiotów humanistycznych. Na poziom indukcji magnetycznej zmierzonej w pracowniach informatycznych miał wpływ stan techniczny zainstalowanego w nich sprzętu komputerowego, a także ich rok produkcji. Starsze komputery generowały wyższe poziomy indukcji magnetycznej w porównaniu do sprzętu nowego. W jednej ze szkół podstawowych w części budynku, którego wiek wynosił około 120 lat, w salach humanistycznych, zmierzona indukcja magnetyczna przekraczała 150 nT. W innej szkole podstawowej zlokalizowanej w silnie zindustrializowanym terenie przykopalnianym zmierzona w pracowniach informatycznych indukcja magnetyczna przekraczała 400 nT, a w salach humanistycznych tej szkoły, osiągała poziom 100 nT. Najwyższe poziomy indukcji magnetycznej zmierzono w dwóch szkołach, w których zainstalowane były transformatory, indukcja w salach lekcyjnych jednej z tych szkół osiągała wartość 200 nT. WNIOSKI Zróżnicowane poziomy indukcji magnetycznej wiążą się z rodzajem sprzętu komputerowego znajdującego się na wyposażeniu w pracowniach informatycznych, dlatego po ich zainstalowaniu należy ocenić poziom ekspozycji dzieci i młodzieży na pole magnetyczne.
12
Content available remote Iluminowanie obiektów zabytkowych
63%
|
2010
|
tom z.57[271], nr 4
549-556
PL
Referat zawiera omówienie stosowanych w praktyce metod wizualizacji iluminacji architektonicznych. Dokonano ich oceny pod kątem użyteczności w tworzeniu wielowariantowych koncepcji iluminacji architektonicznych oraz specyfikacji sprzętu oświetleniowego. Podjęto także próbę wyodrębnienia kluczowych elementów wizualizacji iluminacyjnych obiektów zabytkowych, istotnych z punktu widzenia ochrony konserwatorskiej oraz właściwej interpretacji wyników obliczeń oświetleniowych, realizowanych na bazie aplikacji graficznych.
EN
The paper contains the discussion of methods applied in practice of visualization architectural illuminations. The methods are reviewed with regard to usefulness in creating the multi-variant conceptions of architectural illuminations as well as in specification of lighting equipment. In this paper is also undertaken a study of singling out the main elements of visualization of the illuminations of antique objects, which are essential for the conservatory protection's point of view as well as for the proper interpretation of results of lighting calculations, realized on base of graphic applications.
|
2008
|
tom R. 62, nr 11
10-16
PL
We współczesnym świecie liczba przekazów marketingowych już dawno przekroczyła możliwości percepcji i zapamiętywania przez konsumenta, dlatego jest on coraz trudniejszym celem dla działań marketingowych producentów czy właścicieli marek. Wiedząc, że wiele decyzji konsumenci podejmują przed półką sklepową, producenci i właściciele marek powinni większą uwagę zwrócić na komunikację w miejscach sprzedaży.
EN
In the contemporary world, when the amount of marketing messages is far beyond the possibilities of human perception, modern consumer becomes more and more difficult target for producers and brand owners. The knowledge about consumer decisions being made just behind the shop shelves turns marketing communication efforts to the point of sale.
first rewind previous Strona / 4 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.