This paper describes a new and efficient method for quantifying and detection of the source of distortion caused by a single customer in a case when many other customers exist in a power grid. It is based on measuring distortion power, a component of apparent power that only exists with a nonlinear load. Different definitions for distortion power calculation are investigated. All these definitions show without doubt that the proposed method is feasible. Moreover, this method allows to develop fair and reliable billing schemes for controlling harmonic pollution. Measurement and simulation results confirm the effectiveness and applicability of the method. The proposed solution is suitable for software/hardware upgrade of existing electronic power-meters.
EN
The work presents a DC power supply with power factor correction (PFC). This device is also equipped with a parallel active filter function, which enables the possibility of compensation (minimization) of reactive and distortion power, generated by a group of loads, connected to the same power grid node. A passive filter with variable inductance applied at the input of the power supply allows for a significantly improvement in quality of the system control (given specific criteria), as compared to the solution with a filter with fixed parameters. This is possible by increasing the dynamics of current changes at the power supply input (extending its “frequency response”). The paper presents the principle of operation as well as structures and models of the power supply control system and its power stage. Selected test results its power of the simulation model of the electric system with the power supply, in various operating conditions, are also presented.
EN
Electrified railways are an example of AC single phase distribution networks. A non-negligible amount of active and nonactive power may be related to harmonics, especially for distorted highly-loaded systems. The paper considers the relevance of the harmonic power terms in order to identify distortion sources in a single-point perspective, in line with the approach of EN 50463 for the quantification of the power and energy consumption. Some single-point Harmonic Producer Indicators (HPI) based on harmonic active power direction and nonactive distortion power terms are reviewed and evaluated using pantograph voltage and current measured during several hours of runs in two European AC railways (operated at 16.7 and 50 Hz). The HPI based on active power shows to be consistent and provides detailed information of rolling stock characteristic components under variable operating conditions; those based on nonactive distortion power are global indexes and hardly can operate with complex harmonic patterns in variable operating conditions.
6
Content available remote Moce w komutowanych obwodach elektrycznych. Spektralne rozproszenie mocy
63%
PL
Autor opisuje definicje różnych rodzajów mocy elektrycznej w odniesieniu do prostego obwodu o zmiennej strukturze, w którym występuje zjawisko spektralnego rozproszenia mocy i konwersji mocy. Autor ilustruje względność pomiarów wielkości w obwodach elektrycznych. Wyjaśnia metodę analizy nieliniowych , komutowanych obwodów elektrycznych.
EN
The author interprets different types of electric power in relation to the circuit with alternating structure. The phenomena of spectral dispersion of energy (power) as well as the conversion of energy are described. The author illustrates relativity of measurement of electrical magnitudes in electrical circuits. The design principle for analysing the non-linear, electrically commutated circuits is also explained.
7
Content available remote Critical comments on the Conservative Power Theory (CPT)
63%
EN
Main features of the Conservative Power Theory (CPT) are examined in the paper. It was concluded that the “reactive energy” as defined in CPT cannot be regarded as a physical quantity. It was demonstrated that separation of the void reactive current can lead to wrong conclusions at a reactive compensator design. It was shown that distortion power defined in the CPT has no relation to mutual distortion of the load voltage and current. The meaning of the term “conservative” as used in the CPT, is discussed as well. It is emphasized that the conservative property of the “reactive energy” is only mathematical, but not physical property of that “energy”.
PL
W artykule przeanalizowano główne właściwości Zachowawczej Teorii Mocy (ang. Conservative Power Theory - CPT). Pokazano, że zdefiniowana w CPT „energia reaktancyjna” nie może być uważana za wielkość fizyczną. Pokazano, że wyodrębnienie z prądu odbiornika „prądu bezużytecznego” (ang.: „void current”) może prowadzić do błędnych wniosków odnośnie kompensacji reaktancyjnej, a ponadto, że zdefiniowana w CPT moc odkształcenia nie ma związku ze wzajemnym odkształceniem prądu i napięcia odbiornika. W artykule analizowane jest także znaczenie pojęcia „zachowawcza”, użytego w nazwie CPT. Pokazano, że „energia reaktancyjna” ma właściwość zachowawczą tylko w sensie matematycznym, lecz nie w sensie fizycznym.
8
Content available remote Zasilacz sieciowy z przestrajalnym filtrem indukcyjnym
63%
PL
W artykule zaprezentowano rozwiązanie zasilacza sieciowego z przestrajalnym filtrem indukcyjnym, który odznacza się dodatkowo możliwością aktywnej kompensacji mocy biernej i mocy odkształcenia, generowanej przez inne odbiorniki dołączone do tego samego węzła sieci elektroenergetycznej. Użyty w układzie pasywny filtr, w postaci cewki o zmiennej indukcyjności, pozwala na uzyskanie dużej dynamiki zmian prądu wejściowego zasilacza, co znacząco poprawia jakość procesu kompensacji. W artykule zaprezentowano zasadę działania zasilacza oraz struktury i modele jego układów sterowania i silnoprądowego. Przedstawiono również wybrane wyniki badań modelu symulacyjnego układu w różnych warunkach jego pracy.
EN
The article presents the solution of the power supply with a tunable inductive filter. The power supply is characterized additionally by the possibility of compensation of both reactive power and deformation power, generated by other loads connected to the same power grid node. The passive filter with tuned inductance is used in the system for obtaining a high dynamics of the input current of the power supply. This one significantly improves the quality of compensation process. The article presents the principles of the system operation as well as the structure of the control circuits and the power stage of the system. Selected results of the tests of the system simulation model, for various operating conditions, are presented too.
9
Content available remote The Efficient Technique for Harmonic Sources Detection AT Power Grid
63%
EN
In this paper, we propose a new and efficient method for detection and quantifying the level of distortion caused by non-linear loads on the power grid. It is based on measurement of distortion power. Simulated and measured results confirm its effectiveness when implemented within electronic power-meters. The proposed solution can easily be added as an option to existing solid-state power-meters. It can be implemented as a software update or in the form of hardware upgrade within a dedicated DSP.
PL
W artykule zaprezentowano metodę detekcji oraz oceny zakłóceń energii w sieci energetycznej wywołanych przez odbiorniki nieliniowe. Wyniki symulacyjne potwierdzają skuteczność metody.
10
Content available remote Budeanu’s concept of reactive and distortion power revisited
63%
EN
Budeanu’s concept of reactive and distortion power for systems operating under nonsinusoidal conditions has been subject to criticism throughout the past decades, which finally led to its removal from the latest standards. Recently, some new results are presented that shed a different light on Budeanu’s reactive power and its compensation. In this paper, a further analysis is presented to reveal the possibility to endow Budeanu’s reactive and distortion powers with physical meaning. For linear and time-invariant systems it is shown that Budeanu’s reactive power is representing the mean value of the moving average of the difference between the total magnetic and the electric energy. Budeanu’s distortion power, after an appropriate decomposition, represents a measure of the power fluctuations around the active power and Budeanu’s reactive power.
PL
Teoria Budeanu dotycząca mocy w obwodach niesinusoidalnych była w ostatnich latach krytykowana i w rezultacie usunięta z norm. Obecnie wraca się do niektórych elementów tej teorii. W artykule zaprezentowano analizę wskazującą w jakich warunkach teoria Budeanu może być stosowana. Po odpowiedniej dekompozycji moc odkształcona jest miara˛ fluktuacji mocy wokół wartości średniej mocy czynnej i mocy biernej wg Budeanu.
EN
The paper is the second part of the work, devoted to a DC power supply with a power factor correction function. The power supply is equipped additionally with a shunt active power filter function, which enables the compensation of reactive and distortion power, generated by loads, connected to the same power grid node. A tunable inductive filter, included at the input of the power electronics current source – the main block of the power supply – allows for an improvement of the quality of the system control, compared to the device with a fixed inductive filter. This improvement was possible by extending the current source “frequency response”, which facilitated increasing the dynamics of current changes at the power supply input. The second part of the work briefly reminds the reader of the principle of operation and the structures of both the power supply control system and its power stage. The main purpose of this paper is to present the selected test results of the laboratory model of the electric system with the power supply.
EN
The paper deals with the possibilities of the improvement of the accuracy and the information value of the assessment of the quality of electric energy, based on separate components of instantaneous power. We proved the efficiency of the use of the singled-out component of the distortion power and the coefficients for the identification of the consumers causing nonlinear distortions in the supply network, calculated with the use of the introduced value of the effective power. The obtained results can be used as a part of the systems of technical accounting of electric energy for the creation of the efficient systems of the compensation for nonlinear distortions.
PL
W artykule przedstawiono możliwości poprawy dokładności i wartości informatywnej oceny jakości energii elektrycznej, bazując na składnikach mocy chwilowej. Udowodniono skuteczność użycia pojedynczych składników mocy zniekształceń oraz współczynników do identyfikacji odbiorców, powodujących nieliniowe zniekształcenia w sieci zasilającej obliczane przy użyciu wartości wejściowej mocy skuteczne. Otrzymane wyniki mogą być u żyte jako część systemów technicznej ewaluacji energii elektrycznej dla stworzenia efektywnych systemów kompensacji zniekształceń nieliniowych.
PL
Przedmiotem artykułu jest dyskusja nad "jednolitą nową koncepcją mocy biernej prądu niesinusoidalnego w dziedzinie czasu" przedstawioną w przez Prof. Adama Skopca i dr. inż. Czesława Steca w Przeglądzie Elektrotechnicznym, R. 84, Nr. 6/2008. Koncepcja ta dotyczy definiowania mocy biernej Budeanu w dziedzinie czasu. Moc ta została oryginalnie zdefiniowana w dziedzinie częstotliwości. W dyskusji tej zwraca się uwagę na to, że moc ta, a także moc odkształcenia Budeanu, błędnie interpretują zjawiska w obwodzie elektrycznym i po osięmdziesięciu latach od ich wprowadzenia nie mają one ani poznawczej ani technicznej wartości. W dyskusji tej pokazano też, że obecnie tylko dziedzina częstotliwościowa ujawnia wszystkie zjawiska energetycznye w obwodach elektrycznych.
EN
Discussion on "a uniform concept of reactive power of nonsinusoidal currents in a time-domain,' by Prof. Adam Skopec and dr. inż. Czesław Stec, published in Przeglad Elektrotechniczny, R. 84, Nr. 6/2008, is presented. The concept results in Budeanu reactive power definition in time-domain. Originally, it was defined in the frequency-domain. It is pointed out in this discussion that Budeanu reactive and distortion powers misinterpret power phenomena in electrical circuits and, after eighty years since the Budeanu reactive and distortion powers were introduced to electrical engineering, these two powers do not provide either cognitive or practical applications. It was also shown that presently, only the frequency-domain approach makes identification of power phenomena in electrical circuits possible.