Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  direct power control
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Predictive direct power control of three-phase boost rectifier
100%
EN
In this paper, a new control scheme of an active boost rectifier has been presented. Proposed power control method uses a discretetime model of the converter to predict future behaviour for all possible voltage vectors. The most effective vector is chosen for next sampling period by minimizing a cost function. Presented Predictive Direct Power Control (P-DPC) scheme has been compared with classical Switching Table based Direct Power Control (ST-DPC) method. Laboratory results shows that predictive control in relation to classical ST-DPC method works properly at low sampling frequency and owns better dynamic and steady state performance.
2
Content available remote Predykcyjne algorytmy sterowania trójfazowym przekształtnikiem AC/DC
80%
PL
Dzięki zastosowaniu dodatkowej modulacji wektorowej możliwe jest całkowite zredukowanie uchybu wektora prądu w pojedynczym okresie próbkowania procesora, zmniejszenie tętnień prądu sieciowego i zapewnienie stałej częstotliwości przełączeń. Przedstawiono wyniki badań symulacyjnych, potwierdzające poprawność przeprowadzonej analizy.
EN
W artykule przedstawiono propozycję nowego, predykcyjnego algorytmu sterowania trójfazowym przekształtnikiem AC/DC. Algorytm bazuje na pryncypiach metody DPC (Direct Power Control). In This article a new, predictive control methods of the AC/DC inverter are presented. Both methods are based on the Direct Power Control algorithm and the current error vector minimization criteria. The main assumption of the predictive DPC-2V-[delta]and DPC-2V-[delta]algorithms are presented. The analysis correctness is acknowledged by the simulation investigation results.
3
Content available remote Nowa metoda sterowania trójfazowym przekształtnikiem AC/DC
60%
PL
Praca dotyczy sieciowego przekształtnika AC/DC pracującego jako źródło prądowe. Referat przedstawia nowy sposób sterowania przekształtnikiem, bazujący na metodzie DPC, który zapewnia jednostkowy współczynnik mocy i minimalizuje zawartość wyższych harmonicznych w prądzie pobieranym z sieci. Zaproponowana metoda opiera się na zasadzie wyboru wektorów prądu prostownika w zależności od zadanej wartości prądu stałego i prądu pobieranego przez filtr pojemnościowy. Poprawność działania algorytmu potwierdzają wyniki symulacji w środowisku MATLAB/Simulink.
EN
The paper presents a new control algorithm for Current Source Rectifier supplied from the grid, based on Direct Power Control. Proposed method corrects power factor and reduces higher harmonics in phase current. The algorithm chooses proper space vector of CSR according to the reference direct current and filter current. Properties of the new method are shown in simulations carried out using MATLAB/Simulink.
4
60%
EN
A Direct Power Control Space Vector Modulated (DPC-SVM) for 3-phase PWM rectifier with compensation of higher harmonics function is presented. The active and reactive power is used as a control variables for the PWM rectifier and active filtering operation. As a result lower number of coordinate transformations are required. Simulated as well as experimental waveforms under steady state and dynamic performance are presented. Among the main advantages of DPC-SVM are: simple algorithm, good dynamic and operation at constant switching frequency. Additionally a line voltage sensors were replaced by the virtual flux estimator which provide almost sinusoidal line current in case of distorted line voltage.
PL
Artykuł przedstawia układ prostownika PWM z możliwością kompensacji wyższych harmonicznych prądu sieci. Wyeliminowano czujniki napięcia po stronie sieci zasilającej, dzięki zastosowaniu strategii sterowania bazującej na wirtualnym strumieniu. Opracowany układ sterowania charaktery/uje się prostym algorytmem, łatwym do realizacji przy zastosowaniu procesora sygnałowego. Zostały przedstawione podstawy teoretyczne oraz badania symulacyjne i eksperymentalne w stanic ustalonym i stanach dynamicznych dla pracy prostownikowej i przy włączonej funkcji filtracji aktywnej. Wyniki hadań pokazały szereg zalet bezpośredniego sterowania mocą z estymatorem wirtualnego strumienia, w szczególności zapewnienie sinusoidalnego prądu w przypadku odkształconego napięcia sieci.
EN
This paper presents an improved Virtual Flux-based Direct Power Control (VFDPC) applied for a three-phase pulse width modulation rectifier. The proposed control approach incorporates an enhanced Virtual Flux estimator made up of a cascade seconddegree low-pass filter. This latter guarantees the attenuation of the highest harmonics. The introduced control concept presented in this paper has interesting features such as reducing the current harmonics distortion. In other words, it ensures that the input current drawn from the power supply is perfectly sinusoidal whatever the state of the network voltage. The proposed method also allows to maintain the DC side capacitor voltage at the required level and assure that the input current is in phase with the respective voltage to satisfy the unity power factor function. The results obtained from the numerical simulation have proved the effectiveness of the proposed method for disturbed grid voltage and system parameters variation.
6
Content available remote Genetic algorithm optimization of a SAPF based on the fuzzy- DPC concept
51%
EN
This article presents a study on the use of the concept of direct power control (DPC) based on intelligent techniques in the control of a shunt active power filter (SAPF). In order to improve harmonic mitigation and reactive power compensation capabilities, the conventional switching table is replaced by a fuzzy inference system to generate the switching sequences of the shunt active power filter. To ensure an active power exchange stable and efficient, the DC voltage of the SAPF in controlled using an integrated proportional controller (PI) optimized by a heuristic optimization technique based on genetic algorithms (GA). The combination of two intelligent techniques in this proposed control strategy makes it possible to reduce ripples in different variables of the SAPF, to maintain the direct voltage at their reference value and to improve the THD of the grid current. The numerical simulation results obtained under Matlab / Simulink confirm the importance of the SAPF's proposed control technique
PL
W artykule opisano wykorzystanie metody DPC (direct power control) do poprawy parametrów bocznikowego filtru aktywnego SAPF. Konwencjonalna tabela przełączeń jest zastąpiona przez system logiki rozmytej. Do optymalizacji filtru wykorzystano też algorytm genetyczny.
EN
The paper presents a concept of a control system for a high-frequency three-phase PWM grid-tied converter (3x400 V / 50 Hz) that performs functions of a 10-kW DC power supply with voltage range of 600÷800 V and of a reactive power compensator. Simulation tests (in PLECS) allowed proper selection of semiconductor switches between fast IGBTs and silicon carbide MOSFETs. As the main criterion minimum amount of power losses in semiconductor devices was adopted. Switching frequency of at least 40 kHz was used with the aim of minimizing size of passive filters (chokes, capacitors) both on the AC side and on the DC side. Simulation results have been confirmed in experimental studies of the PWM converter, the power factor of which (inductive and capacitive) could be regulated in range from 0.7 to 1.0 with THDi of line currents below 5% and energy efficiency of approximately 98.5%. The control system was implemented in Texas Instruments TMS320F28377S microcontroller.
8
Content available remote Advanced topology for grid-connected photovoltaic system based PWM rectifier
41%
EN
This paper proposes an advanced topology for grid-connected photovoltaic systems (GCPVS) based on sliding mode control (SMC). The proposed topology exploits the generation and regeneration modes of the three-phase PWM rectifier well suited for high power quality. In addition, it has the advantage of eliminating the inverter and the diode rectifier stages used in the classical structure and replacing them by a PWM rectifier. For maximum power point tracking (MPPT) of the PV generator, DC-Link voltage control and direct power control (DPC), a sliding mode controllers (SMC) are used in order to obtain high accuracy and fast dynamic response against meteorological and load variations. To verify the effectiveness of the control applied on the proposed topology, a wide simulation results are carried out under MATLAB-SIMULINK environment for different operating conditions that confirm the feasibility of the proposed topology.
PL
W artykule zaproponowano zaawansowaną topologię systemów fotowoltaicznych podłączonych do sieci (GCPVS) w oparciu o sterowanie trybem ślizgowym (SMC). Proponowana topologia wykorzystuje tryby generowania i regeneracji trójfazowego prostownika PWM dobrze przystosowanego do wysokiej jakości energii. Dodatkowo ma tę zaletę, że eliminuje stosowane w klasycznej konstrukcji stopnie falownika i prostownika diodowego i zastępuje je prostownikiem PWM. Do śledzenia maksymalnego punktu mocy (MPPT) generatora fotowoltaicznego, sterowania napięciem DC-Link i bezpośredniego sterowania mocą (DPC), stosowane są kontrolery trybu ślizgowego (SMC) w celu uzyskania wysokiej dokładności i szybkiej odpowiedzi dynamicznej na zmiany pogody i obciążenia . Aby zweryfikować skuteczność zastosowanego sterowania na proponowanej topologii, przeprowadza się szerokie wyniki symulacji w środowisku MATLAB-SIMULINK dla różnych warunków pracy, które potwierdzają wykonalność proponowanej topologii.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.