Ten serwis zostanie wyłączony 2025-02-11.
Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  diffusion dialysis
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper studies the recovery and concentration of Zn2+ and Cu2+ metal ions from industrial rinse water containing a mixture of Zn2+, Cu2+, Ca2+, Mg2+, K+, and Na+ salts. Transport and separation experiments were performed in a continuous membrane extraction (CME) system, i.e. in the membrane system composed of two contactors with a cation-exchange polymer membrane (Neosepta CMX) and an organic liquid (liquid membrane) circulating between. The organic solution was composed of kerosene and di-(2-ethylhexyl)-phosphoric acid or salicylaldoxyoxime (Acorga P-50) as the active extractant/carrier. The feed solution has been taken from a rinsing tank working in an industrial electroplating plant. Sulfuric acid (1 M) was applied as the stripping medium for metal ions. The total flux of target metals (Zn2+ and Cu2+) in the MHS with Acorga P-50 or D2EHPA was 97.1% and 71.4%, respectively. The product of the CME process can be further de-acidified by diffusion dialysis with the use of an anion-exchange membrane (Neosepta AFN-7). The coefficients of separation, enrichment, and up-hill transport characteristics indicate that the CME system with Acorga P-50 can be considered a part of a technology for the efficient recovery of Cu2+ and Zn2+ in metal finishing plants.
PL
W pracy scharakteryzowano dialityczne procesy membranowe - dializę dyfuzyjną, elektrodializę monopolarną i elektrodializę bipolarną oraz przedstawiono możliwości zastosowania tych procesów do odzyskiwania wartościowych składników ze ścieków przemysłowych. Przeprowadzono analizę ekonomiczną odzyskiwania kwasów nieorganicznych (siarkowego oraz azotowego i fluorowodorowego) ze ścieków po trawieniu metali oraz soli niklu z wody z płukania po galwanizacji. Określono koszty związane z wprowadzeniem technologii membranowej do układu technologicznego oczyszczania ścieków w trawialni i galwanizerni i porównano je z kosztami klasycznej technologii oczyszczania opartej na neutralizacji ścieków. Stwierdzono, że w każdym z analizowanych przypadków koszt wprowadzenia nowej technologii (tj. technologii membranowej) jest niższy od kosztu technologii klasycznej. W procesie odzyskiwania kwasu ze zużytej kąpieli trawiącej metodą dializy dyfuzyjnej osiąga się czas zwrotu inwestycji (3-5 lat) nawet przy niskiej wartości rynkowej kwasu. Elektrodializa bipolarna, jako metoda odzyskiwania kwasu ze stężonych ścieków potrawiennych, jest korzystna ekonomicznie w przypadku kosztownych kwasów. Procesem szczególnie atrakcyjnym ekonomicznie jest odzyskiwanie metodą elektrodializy monopolarnej soli niklu z wody z płukania po galwanizacji. Z powodu wysokiej wartości rynkowej soli niklu, poniesione nakłady zostają zwrócone już po jednym roku eksploatacji instalacji do elektrodializy. Ponadto w procesie tym otrzymuje się wodę o obniżonym stężeniu soli niklu, która jest ponownie wykorzystywana w procesie płukania po galwanizacji.
EN
The paper includes a characterization of dialytic membrane processes, i.e. diffusion dialysis, monopolar electrodialysis and bipolar electrodialysis, and presents potential applications of these processes to the recovery of valuable substances from industrial effluents. Cost analysis was carried out for the recovery of inorganic acids (sulfuric, nitric and hydrofluoric) from metal-etching effluents, and the recovery of nickle salt from post-electroplating wash water. The costs involved in the implementation of the membrane technology into the treatment trains for the effluents from etching and electroplating plants were assessed and compared with the costs of the conventional treatment technology involving the neutralization of the effluents. In every instance the costs of implementing the membrane technology were found to be lower than those of applying the conventional neutralization technology. As for the process of acid recovery from spent etching bath by diffusion dialysis, the repayment of the investment takes from 3 to 5 years even if the market price of the acid is low. Bipolar electrodialysis as a method of acid recovery from concentrated etching effluents is cost-effective when the market price of the acids is high. Of the membrane processes analyzed, monopolar electrodialysis was found to be particularly attractive (in economic terms) when used for the recovery of nickel salt from post-electroplating wash water. Owing to the high market price of nickle salt, relevant expenditure is repaid after only one year of operation of the electrodialysis system. What is more, the process yields water of a reduced nickle salt concentration and thus enables its reuse for rinsing purposes after electroplating.
3
Content available remote Utilization methods of spent hydrochloric acid from hot dip zinc galvanizing
67%
|
|
tom Vol. 5, nr 4
34-36
EN
Three methods were used for zinc removal from spent hydrochloric acid containing 3.06 mol/1 HC1, 79.8 g/1 Fe(II), 4.84 g/1 Zn(II). In bulk liquid membrane system using 80% tributyl phosphate in kerosene as a membrane phase, it was possible to separate Zn(II) with the initial flux of 0.40 mol/m2 h. The process was strongly disturbed by the competitive transport of Fe(III) if present. Diffusion dialysis enabled to separate very effectively Fe(II) with separation factor over 100 in relation to Zn(II), but Zn(II) was transported together with HC1 with flux values of 0.55 and 19.6 mol/m2h, respectively (membrane FT FAD, Fuma Tech). Anion exchange using both strong basic Lewatit M500 and weak basic Lewatit MP64 (Bayer) absorbed effectively Zn(II) with exchange capacity 0.65 and 0.85 mol Zn/L, respectively. Regeneration with water enabled to recover 70 - 80% of absorbed zinc in the solution containing 13 - 15 g/1 Zn(II) and 0.01 - 0.4 g/1 Fe(II).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.