The results of research on the possibility of utilizing a part of a capillary gas chromatographic column as a trap for isolating and enriching air analytes on the basis of the denudation principle are presented in the paper. The research was based on model studies and included: a study of the enrichment process of selected organic compounds on a part of a capillary column, determining the influence of analyte concentration in the gaseous phase and the flow rate of a standard gas mixture on the enrichment process in the denuder, determination of the partition coefficients between the gas phase and the sorption layer of the denuder, Kfs of selected organic compounds (benzene, ethylbenzene, toluene, o-xylene, chlorobenzene), frequently present in the air as contaminants. The values of the partition coefficient Kfs, for these compounds are: 440 for benzene; 1060 for toluene; 2770 for ethylbenzene; 3660 for o-xylene and 3400 for chlorobenzene. Partition coefficients were found to be constant in the studied range of concentration and gaseous mixture flow. rate. A piece of a capillary column coated with polydimethylosiloxane can be used as a tube denuder.
PL
Przedstawiono wyniki badań nad mozliwością wykorzystania odcinka kapilarnej kolumny chromatograficznej jako pułapki do izolacji i wzbogacania analitów z powietrza na zasadzie denudacji. Zakres wykonanych prac o charakterze badań modelowych obejmował: zbadanie przebiegu procesu wzbogacania wybranych związków organicznych w odcinku kapilary; określenie wpływu natężenia przepływu strurnienia gazowej mieszaniny wzorcowej na przebieg procesu wzbogacania w denuderze, wyznaczenie współczynników podziaru Kfs wybranych związków organicznych pomiędzy fazą gazową i warstwą sorpcyjną denuderu. Powyższe badania byłyy przeprowadzone dla wybranej grupy zwiąków organicznych (benzen, etylobenzen, toluen, o-ksylen, chlorobenzen), często występujących w powietrzu jako jego zanieczyszczenia. Na podstawie przeprowadzonych
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The results of research on the possibility of utilizing a part of a capillary gas chromato-graphic column as a trap for isolating and enriching air analytes on the basis of the denudation principle are presented. The research was based on model studies and included: a study of the enrichment process of selected organic compounds on a part of a capillary column, determining the influence of the flow-rate of a standard gas mixture on the enrichment process in the denuder, determination of the partition coefficients Kfs, between the gas phase and the sorption layer of the denuder of selected organic compounds (benzene, ethylbenzene, toluene, o-xylene), frequently present in the air as contaminants. The values of the partition coefficient for these compounds are: 4.4xl02š0.37xl02 for benzene; 1.06xl03 š 0.052xl03 for toluene; 2.77xl03 š 0.089x103 for ethylbenzene; and 3.7x10(3)š 0.48x103 for o-xylene. The values were determined at different flow rates of the standard gas mixture, in 0.6 to 5.0 cm3min"' range, and found independent of the flow rate within this range.
PL
Przedstawiono wyniki badań możliwości wykorzystania odcinka kapilarnej kolumny chromatograficznej jako pułapki do izolacji i wzbogacania analitów z powietrza na zasadzie denudacji. Zakres wykonanych prac o charakterze badań modelowych obejmował: zbadanie przebiegu procesu wzbogacania wybranych związków organicznych w odcinku kapilary; określenie wpływu natężenia przepływu strumienia gazowej mieszaniny wzorcowej na przebieg procesu wzbogacania w denuderze, wyznaczenie współczynników podziału ATfs wybranych związków organicznych pomiędzy fazą gazową i warstwą sorpcyjną denudera. Powyższe badania były przeprowadzone dla wybranej grupy związków organicznych (benzen, etylobenzen, toluen, o-ksylen), często występujących w powietrzu jako jego zanieczyszczenia. Wartości współczynnika podziału tych związków, wynosiły w przypadku benzenu 4.4 x l02 š0.37 x l02, toluenu l .06 x 103 š 0.052 x 103, etylobenzenu 2.77 x l03 š0.089 x 103 oraz o-ksylenu 3.7 x 103š 0.48 x 103dla różnych natężeń przepływu gazowej mieszaniny wzorcowej (0.6; l and 5 š 0,05 cm3min(-3). Stwierdzono, że współczynnik podziału nie zależy od natężenia przepływu strumienia gazu przepływającego w badanym przedziale natężeń.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.