The main problem preventing the use of digital relay protection mathematical models for real devices setting up is the confidentiality of the information about its internal configuration. This mainly concerns the input circuits (measuring part) of the protection, the components of which introduce the most significant errors. In this case, an arbitrary choice of the configuration may lead to incorrect results. The identification of the internal structure by standard methods, in particular by a real interpolation method, cannot be carried out in practice, due to the need to have input and output signals. In this regard, the purpose of the research was to develop a method of identification according to the time for formation of tripping signal. Identical signals were transmitted to real device and mathematical model of protection. The starting point of the time reference was the moment when the input signal reached a threshold; the final point was the time of tripping command appearance, unlike similar studies, where the time was determined by the closure of the output relay contacts. The research was carried out for 144 different combinations of the measuring part elements: auxiliary converters, analog filters, digital finite impulse response filters. As a result, the combination in which the smallest deviation from the tripping time of the real device was observed in all studied modes was selected as the most ‘optimal’. Performing such comparisons is the main way to make the model closer to real protection.
PL
Analizowano cyfrowe zabezpieczenie przekaźnikowe I jego model matematyczny przy założeniu, że nie jest znana jego struktura wewnętrzna. Zaproponowano metodę identyfikacji bazując na pomiarze czasu między przekroczeniem przez sygnał wejściowy wartości progowe a wyłączeniem.
|
|
tom Z. 177
51--59
PL
Wyłączniki szybkie stosowane w podstacjach trakcyjnych muszą spełniać wiele wymagań, od czego zależy ich prawidłowa praca, co przekłada się na bezpieczeństwo i ruch pociągów. Z tego względu przed dopuszczeniem do eksploatacji wyłączników szybkich, przechodzą one liczne badana laboratoryjne, w tym na zgodność z wymaganiami norm PN-EN 50123-1 i PN-EN 50123-2. Z uwagi na to, że zapisy norm są ogólne, a czasem mało precyzyjne, wyniki badań laboratoryjnych nie zawsze przekładają się na parametry wyłączników podczas eksploatacji w warunkach rzeczywistych. W  niniejszym artykule przedstawiono zagadnienie dotyczące wyłączania prądu stałego oraz wpływu parametrów obwodu na czas wyłączania. Podano przykład, w którym ten sam typ wyłącznika badany w układzie spełniającym wymagania normy, lecz o różnych parametrach, może spełniać lub nie wymagania dotyczące całkowitego czasu wyłączania. W artykule odniesiono się również do innego parametru wyłącznika szybkiego, jakim jest wartość przepięcia łączeniowego. Przedstawiono wyniki badań, na podstawie których określono wartość maksymalną przepięcia łączeniowego dopuszczalną dla wyłączników pracujących w podstacjach trakcyjnych w Polsce. W ten sposób odniesiono się do zapisów norm branżowych określających, że wartość przepięć łączeniowych może być określona przez użytkownika wyłączników szybkich prądu stałego.
EN
High speed circuit breakers (HSCB) applied in traction substations must meet several requirements conditioning their proper performance, which enhances train safety and traffic. Due to this fact, prior to high speed circuit breakers placing into operation, they are subject to several laboratory tests, including tests checking compliance with PN-EN 50123-1 and PN-EN 50123-2 standards requirements. As many provisions of standards are general and sometimes not very precise, laboratory tests results do not always translate into HSCB parameters in operational use under realistic conditions. The article features the issue concerning DC breaking and the impact of the circuit parameters on the breaking time. An example was given when the same HSCB type was tested in a circuit which meets the standard requirements but bears diff erent parameters and that type can or not fulfi ll the requirements relating to the total breaking time. The article also refers to another HSCB parameter, i.e. the value of switching overvoltage. The test results were presented which were the basis to determine the maximum limit value of switching overvoltage for breakers installed in traction substations in Poland. In this way the reference was made to provisions of industry standards which state that the value of switching overvoltage may be determined by a HSCB user.
PL
W artykule przedstawiono metodę analizy kluczowych parametrów wyłączników SN w czasie ich eksploatacji. Do podstawowego zestawu parametrów charakteryzującego jakość wyłącznika należą czasy załączania oraz czasy wyłączania poszczególnych jego kolumn. W celu zwiększenia pewności w odniesieniu do wartości tych czasów, do ich wyznaczenia, oprócz analizy stanów generowanych przez łączniki krańcowe (skojarzone z wyłącznikiem SN), wykorzystano także wyniki analizy wartości chwilowych prądów fazowych. Zaimplementowany w urządzeniu EAZ algorytm umożliwi dostarczenie służbom eksploatacyjnym informacji pozwalających na wczesną eliminacje ryzyka awarii. Wyznaczone przez algorytm poszczególne czasy stanowią dane wejściowe dla innych procedur np. dla procedury informującej użytkownika o stanie wyłącznika SN.
EN
In the paper there is presented method that allow estimate selected parameters value of circuit breaker. Basis set of circuit breaker parameters contains switch-on times and switch-off times for each column. To obtain results with small level uncertainty, to analysis used boundary switch states (association circuit breaker) and several phase currents samples. The algorithm implemented in protection device provides information which allow on early elimination risk of damage state. The time parameters of circuit breaker constitute input parameters for another software procedures eg. information end user about circuit breaker state.
EN
The paper presents the results of experiments on the relationship between parameters of modulated control signal and gas injectors’ closing time. The experiments were conducted in a test-bed supplied with constant pressure. The modulated control signal was of constant duration, variable duty cycle and variable frequency. The authors prove that reduction of duty cycle causes reduction of injector’s closing time. However, frequency of the signal has no effect on closing time.
PL
W artykule przedstawiono wyniki badań eksperymentalnych wpływu parametrów sygnału sterującego (sygnału modulowanego) na czas wyłączania impulsowych wtryskiwaczy gazu. Badania przeprowadzono na stanowisku sprężarkowym przy stałym ciśnieniu zasilania i czasie trwania impulsu sterującego a zmiennym wypełnieniu i zmiennej częstotliwości sygnału modulowanego. Wykazano, że zmniejszenie wypełnienia sygnału modulowanego powoduje skrócenie czasu wyłączania. Jednocześnie wykazano, że częstotliwość sygnału modulowanego nie wpływa na czas wyłączania.