Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 9

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  computed microtomography
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Natural gas in the Polish Rotliegend Basin occurs in porous and permeable aeolian sandstones, and traps are mostly structural. Lithological traps are rare and occur on the northern slope of the Wolsztyn Ridge where fluvial and aeolian sandstones overlap with alluvial facies. Both fluvial and aeolian sandstones are reservoir rocks in this area. The X-ray micro computed tomography (MCT) results and microscopic observations indicate that the sandstones in lithologic traps on the northern slope of the Wolsztyn Ridge form highly compartmentalized vertical reservoir rocks composed of four types of sandstones. The profiles are dominated by very low-porosity fluvial sandstones (F2), and low-porosity aeolian and fluvial sandstones (A2, F1). The A1 type of sandstones with high porosity (10%) occurs only in some sections of the profiles. The most important diagenetic processes that reduced porosity were compaction and cementation by carbonate cements. All studied sandstones were subjected to the same diagenetic processes. However, each of the processes ran with varying intensity in different types of sandstones. Detailed analyses of pore distribution by MCT methods with respect to primary depositional or lithofacies effects, and secondary diagenetic effects, help to understand the 3D geometry of pores and pore shape-size distributions. The results can be used in the studies of other sandstones with a different origin and age.
2
Content available remote Rentgenowska mikrotomografia komputerowa w badaniu skał zbiornikowych
100%
PL
W artykule omówiono podstawowe zasady mikrotomografii rentgenowskiej (micro-CT), przedstawiono sposób akwizycji danych i rekonstrukcji obrazu oraz zaprezentowano pierwsze własne wyniki badań.
EN
This paper shows basis of roentgen microtomography (micro-CT), acquisition and reconstruction processes, and presents first results.
EN
Results of the nuclear magnetic resonance (NMR) investigations, mercury porosimetry measurements (MP) and computed microtomography (micro-CT), applied to the tight Palaeozoic rocks from the depths lower than 3000 m, were presented to estimate their reservoir potential. NMR signal analysis and interpretation were performed. Based on NMR driven models, permeability and Free Fluid Index were calculated for data sets divided into homogeneous clusters. Computerized mercury porosimetry results visualization and processing provided useful information, as the automatically determined Swanson parameter is correlated with petrophysical properties of rocks. Micro-CT enriched the image of porous space in qualitative and quantitative ways. Homogeneity of pore space structure was discussed using micro-CT approach. Integration of the results in the frame of reservoir parameters from standard laboratory methods and the modern ones resulted in the improvement of methodology for determining the old, deep-seated, hard sedimentary rocks reservoir potential.
|
|
tom Vol. 64, nr 2
105--112
EN
The paper considers the use of high-resolution X-ray computed microtomography (μCT) as a possible method in engineering-geological laboratory research for indicating areas of weakness, location of fissures and determining homogeneity of clay samples. Furthermore, the studies were used to provide methodological guidance. Mio-Pliocene (Neogene) clay samples were taken from an excavation site of the Kopernik underground station in Warsaw. First, natural humidity, bulk density and fraction analyses of samples were made. Secondly, μCT scans were conducted, with the use of copper filters. In the final stage of the study, internal structure images for samples were processed and analysed. Furthermore, a numerical model of dry sample was developed. During the study it was observed that the increase of temperature caused by X-ray radiation has a destructive effect on the sample. This effect was eliminated by applying a protective layer on the sample, using engine oil. The article quantifies the ratio of radiation-heated fissure volume to dry sample volume and the natural fissure volume to sample volume. Moreover, sample areas with different densities or chemical composition were studied. The results lead to the conclusion that the μCT technique is applicable to characterise of Mio-Pliocene clay, supplying internal structure assessment and fissure quantification that allow for samples verification to further engineering geology in-depth analysis.
PL
Praca przedstawia wyniki badań struktur mikroskaffoldów wytwarzanych ze stopu Ti6Al7Nb, w technologii laserowej mikrometalurgii proszków metali. Opracowana technologia wytwarzania mikrostruktur kratowych, umożliwia produkowanie regularnie porowatych struktur, składających się z porów w kształcie sześcianu z walcowymi belkami wpisanymi w jego krawędzie. Celem badań było opracowanie metodologii oceny i charakteryzacji wytworzonych struktur.
EN
This paper presents the investigation results on Ti6Al7Nb micro scaffold structures, manufactured in metal powder Selective Laser Melting process. Developed technology of manufacturing lattice microstructures, can produce regular porous structure consisting of pores in the shape of a cube with cylindrical beams entered in the edges. The aim of the study was to develop a methodology for the evaluation and characterization of the produced structures.
EN
This paper presents for the first time X-ray computed microtomography (μCT) analysis as a technique for Silurian graptolite detection in rocks. The samples come from the Jantar Bituminous Claystones Member of the Opalino core, Baltic Basin, northern Poland. Images were obtained with spatial resolution of 25 μm, which enabled the authors to create a 3-D visualization and to calculate the ratio of fissure and graptolite volume to the total sample volume. A set of μCT slices was used to create a 3-D reconstruction of graptolite geometry. These μCT slices were processed to obtain a clearly visible image and the volume ratio. A copper X-ray source filter was used during exposure to reduce radiograph artifacts. Visualization of graptolite tubaria (rhabdosomes) enabled Demirastrites simulans to be identified. Numerical models of graptolites reveal promising applications for paleontological research and thus for the recognition and characterization of reservoir rocks.
|
|
tom nr 4
4537--4542, CD6
EN
Combination of computed microtomography and fluid flow simulation approach leads to rock permeability estimation as a reservoir parameter deciding about the rock potential to fluid (hydrocarbons and/or formation water) flow in porous space. For the proper simulation run and results two aspects are needed to be considered: modelling approach and the flow regime. The Knudsen number classifies the modelling approach and Reynolds number – flow regime. The Knudsen number and Reynolds number were calculated for the Carboniferous sandstone sample, cored at 3154 m depth and with total porosity obtained from micro-CT equal to 12.6%.
PL
W pracy zostały omówione parametry kryterialne oraz sposoby ich wyznaczania w celu poprawnego modelowania zjawiska przepływu płynu przez ośrodki porowate z zastosowaniem komputerowej mechaniki płynów. Poprawny dobór poszczególnych równań i modeli podczas komputerowej symulacji przepływu płynu wymaga obliczenia kryterialnych parametrów, jakimi są liczba Knudsena i liczba Reynoldsa. Wartości liczb kryterialnych determinują możliwe do zastosowania podejście w modelowaniu przepływów oraz określają zakres charakteru przepływu, jaki występuje w analizowanym przypadku. W pracy przedstawione zostały wyniki obliczeń parametrów kryterialnych dla piaskowca karbońskiego.
PL
Brak klarownych wytycznych suszenia mikrofalowego dla określenia wilgotności czy tylko „podsuszania” gruntów przed właściwymi badaniami cech mechanicznych może prowadzić do niekontrolowanych zmian właściwości fizyko-mechanicznych gruntów. W niektórych przypadkach może to grozić nawet „eksplozją” materiału badawczego. Na podstawie licznych i szczegółowych badań wilgotności sformułowano wskazówki na temat optymalizacji parametrów bezpiecznego wykorzystania mikrofalówek w laboratorium geotechnicznym.
EN
The use of microwave drying to determine the water content or only to “pre-drying” of the soils before the proper tests of their mechanical properties, need to be established in detailed way. Without knowledge of the basic criteria for such procedure, may lead to uncontrolled changes in the physical and mechanical properties of soils - even soil “explosion”. On the basis of detailed water content studies, the guidelines were formulated on optimizing the parameters for the safe use of a microwave oven in a geotechnical laboratory.
|
|
tom nr 469
47--58
PL
W kopalni Rudna nad stropem wyrobisk górniczych odnotowano występowanie poziomu dolomitu, w obrębie którego znajduja się izolowane pułapki z gazem pod wysokim ciśnieniem. Badany poziom stanowi duże zagrożenie dla prowadzonych robót górniczych i jest obiektem prac badawczych. Do oceny bezpieczeństwa prowadzenia prac górniczych konieczna jest znajomość sposobu występowania gazu w przestrzeni porowej badanych dolomitów. Szczególnie, że dotychczas za „niebezpieczne” uważano dolomity o wysokiej porowatości, gdy tymczasem w wielu otworach wiertniczych stwierdzono produkcję gazu z dolomitów o niskiej porowatości. Celem artykułu jest określenie potencjału zbiornikowego badanych dolomitów i interpretacja ich potencjalnego zagrożenia dla prowadzonych prac górniczych. Na podstawie obserwacji mikroskopowych, analizy mikrotomografii rentgenowskiej i badań porozymetrii rtęciowej stwierdzono, że w poziomie zbiornikowym występują trzy typy dolomitów o zróżnicowanym charakterze porowatości: dolomity o dobrych parametrach zbiornikowych, dolomity o obniżonych parametrach zbiornikowych i dolomity o charakterze skały uszczelniającej. Na szczególną uwagę zasługują dolomity o charakterze skały uszczelniającej, które na podstawie badań porozymetrycznych charakteryzują się bardzo niską porowatością. Na podstawie obserwacji mikroskopowych stwierdzono w nich 4% porowatość zamkniętą, w której jest również uwięziony gaz. Obecność gazu zamkniętego w porach dolomitów jest zjawiskiem dość powszechnym, jednak to obecność wysokociśnieniowych pułapek gazowych w obrębie lokalnie bardziej porowatych, mikroszczelinowatych i przepuszczalnych dolomitów stanowi zasadnicze zagrożenie.
EN
Reservoir dolomites saturated with gas under high pressure were found in the ceiling of excavations in a Rudna copper mine in southwestern Poland. Reservoir dolomites are a major concern in the mining industry and the focus of substantial research. High-porosity dolomites are definitively considered "hazardous", but the gas is extracted from the dolomites with low porosity, too. So, it is necessary to know way of gas occurrence in the pore space. This article aims to describe the reservoir potential of the dolomites through pore space characterisation and determine whether the gas can migrate into the excavations. A comprehensive analysis of the distribution of pore size and nature using microscopic observations, X-ray microtomography and mercury porosimetry. The results distinguished three types of dolomites with different porosities: dolomites with high effective porosity, dolomites with reduced effective porosity, and sealed dolomites. Particular attention should be paid to sealed dolomites. Their effective porosity results from mercury porosimetry are very low. However, they also contained 4% closed porosity described from microscopic observations, where gas is accumulated, too. Presence of gas in the closed pores dolomites is a common phenomenon. However, the presence of high-pressure gas traps within locally more porous, microcraced and permeable dolomites is a major threat.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.