Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  chlortetracycline
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In solid biological samples selected cations and anions have been determined by ion chro-matography (1C). Before the analysis, single preparation step has been applied. The proposed procedure allowed one to determine concentration of alkali and alkaline cations (Na+, K+, Mg2+, Ca2+), as well as anions (Cl-, Br-
PL
Zaproponowano procedure przygotowania stałych próbek biologicznych umożliwiającą oznaczanie kationów (Na+, K+ Mg2+, Ca2+) i anionów (Cl-, Br-) w tym samym roztworze metodą wysokosprawnej chromatografii jonowej z detekcjąkonduktomctryczną. Pomiary wykonano używając dwóch kolumn chromatograficznych (z fazami stacjonarnymi zawierającymi grupy sulfonową) trimetyloaminową) oraz trzech eluentów w trybie elucji izokratycznej. Walidację metody przeprowadzono za pomocą analizy certyfikowanego materiału odniesienia (cotton cellulose, IAEA V-9). Metodę zastosowano do analizy próbek różnych gatunków drewna.
EN
An analytical method for the simultaneous determination of tetracycline (TC), oxtetracycline (OTC), chlortetracycline (CTC) with their 4-epimers, and doxycycline (DC) in animal tissues has been developed and validated. The extraction of the analytes from biological matrice was carried out with a 0.02 M oxalic acid (pH=4.0). The samples were cleaned up by using a solid phase extraction procedure with polymeric cartridges. Chromatographic separation was achieved on a C 18 analytical column using a mobile phase consisting of acetonitrile, methanol and 0.02 M oxalic acid in gradient mode. Detection was carried out by UV detector at λ = 355 nm. The method has been validated according to the Commission Decision 2002/657/EC. The recoveries of the analytes from the spiked samples were 50%-80%. The decision limits (CCα) were from 110 to 125 µg/kg and the detection capabilities (CCß) were from 120 to 155 µg/kg, depending on the analytes. The prepared method was successfully verified in the National Residue Control Programme.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.