Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 23

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  chloride ion
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Degradation of sodium alkylbenzenesulfonate (ABS) in the Fenton reagent in the presence of Cl- ions has been studied. An anionic surfactant sodium alkylbenzenesulfonate (C11-C14) has been selected as a model compound. The effect of individual components of the reactive system (H2 O2 , H2 O2 /Cl- , Fe2+/H2 O2 , Fe2+/H2 O2 /Cl- ) on the degree of ABS degradation has been determined. The degree of ABS degradation has been found to be affected by the presence of Cl- ions and the mutual molar ratios of individual components of the system studied. Moreover, it influences on the composition of the post-reaction mixture. The use of the Fenton reagent in the presence of Cl- ions resulted in the formation of chloroorganic compounds in the solution studied. 2,4,6-trichlorophenol was identified in reaction products and its presence was confirmed using the HPLC - MS method and by HPLC with an internal standard. No chloroproducts were identified during degradation of ABS by the system H2 O2 /Cl- . When only H2 O2 was applied, the concentration of the surfactant was unchanged.
EN
Three original three-dimensional Potential Energy Surfaces (PESes) of the reaction have been obtained by Density Functional Theory calculation using the 6-311+G(d) basis to prove an assumption that there action of ClONO2 + Cl- Ž NO3 - + Cl2 in a gas phase is built up of two simpler reactions: ClONO2 + Cl- Ž (O2NOClCl)- and (O2NOClCl)- Ž NO3 - + Cl2. The PESes indicate that the inter mediate compound (O2NOClCl)- called Potential Well Compound (PWC) is trapped by a potential energy well of -13.2 kcal/mol deep. The (O2NOClCl)- PWC in a gas phase is a stable compound at low temperatures and will be examined in the low-temperature in frared spectra. The decomposition of (O2NOClCl)- in a gas phase is dominated by its dynamic effects, and its kinetics is predicted in the present work. In heterogeneous chemistry how ever, the (O2NOClCl)- PWC can not be stable even at ~180 K, due to H2O solvation, leading to decomposition of the PWC. Solvation mechanism for the total reaction has been suggested in this paper.
4
Content available remote Ion transport in rabbit caecum at 12 and 36 months of age
72%
EN
The aim of this study was to investigate the effect of aging on sodium and chloride ions transport in the isolated rabbit coecum. The experiment consisted in measuring PD- transepithelial electrical potential difference mV SM-mechanical stimulation and mechano-sensitivity (dPD) in collected from 12- and 36-month-old rabbits. A modified Ussing system was used for the experiment. Under the incubation in Ringer solution the values of PD and dPD of young rabbit caecum were, respectively, -3.0 ±0.4 mV and -1.2 ±0.3 mV. In 36-month rabbits, on the other hand, the values of these parameters were lower, PD by about 90% whereas dPD by about 83%. Incubation of young rabbits caecum with the presence of amiloride resulted in a reduction of PD by about 17 % and dPD by about 50%, while it did not influence the electrophysiological parameters of caecum in 36-month rabbits. Incubation with bumetanide on young rabbits caecum resulted in PD dropped by about 70% and dPD by about 83%. In the same incubation conditions as those applied for incubation of 36-month rabbits caecum, the level of PD decreased by about 67% while dPD by about 50%. Incubation of young rabbits caecum at the presence of both transport inhibitors resulted in PD decreased by about 87% and dPD by about 83%, whereas that applied for the old rabbits' caecum reduced PD by about 90%, without influencing dPD. Presented data demonstrate that the process of organism ageing inhibits sodium ion transport as well as reduces caecum epithelium sensitivity to mechanical stimuli. Probably, it is a consequence of a reduced with age release of neurotransmitter from sensory terminals; these neurotransmitters modify transepithelial ion transport.
EN
One of the most critical sources of pollutants are road run-offs. Road run-off is a complex mixture of toxicants e.g. heavy metals, de-icing agents, organic compounds and water suspensions of solid substances. One of the most negative impact on the environment has sodium chloride which is used as de-icing agent. In the case of incorrect environment protection in the vicinity of roads pollutants may migrate to groundwater causing hazard to sources of potable water. One of the methods to prevent the migration of pollutants to groundwater is imposing the flow of polluted water through a reactive material filling a permeable reactive barrier (PRB). This paper examines the feasibility of selected reactive materials for the reduction chlorides concentration in road run-offs. Four different reactive materials: zero valent-iron, activated carbon, zeolite and geza rock have been chosen for studies. The tests results indicated that the most popular reactive materials used in PRB technology, activated carbon and zero-valent iron, removed exhibited the highest efficiency in chloride ions removal. Moreover, the composition of road run-off in samples collected along roads in Warsaw was determinated.
PL
Do poważniejszych źródeł zanieczyszczenia środowiska gruntowo-wodnego należą wody spływowe z dróg, które są mieszaniną substancji szkodliwych, złożoną m.in. z metali ciężkich, związków stosowanych do odladzania, związków organicznych i zawiesin. Powszechnie stosowaną substancją do odladzania nawierzchni jest negatywnie oddziaływujący na środowisko chlorek sodu. W przypadku nieprawidłowego zabezpieczenia środowiska gruntowo-wodnego wzdłuż dróg zanieczyszczenia mogą migrować do wód gruntowych, powodując zagrożenie dla źródeł wody pitnej. Jedną z metod zapobiegania tym zjawiskom jest wymuszony przepływ zanieczyszczeń przez materiały reaktywne wypełniające przepuszczalną barierę reaktywną (PRB).Celem badań jest zbadanie przydatności wybranych materiałów reaktywnych do zmniejszenia stężenia chlorków w wodach spływowych z dróg. W artykule przedstawiono analizę czterech materiałów reaktywnych pod kątem usuwania chlorków. Wyniki badań wskazują na to, że materiały, które są najpowszechniej wbudowywane w PRBs – węgiel aktywny i żelazo elementarne, usuwają największą ilość tych zanieczyszczeń. Ponadto, w ramach badań, zbadano skład chemiczny próbek śniegu pobranych wzdłuż dróg w Warszawie.
EN
Channels selective for potassium or chloride ions are present in inner mitochondrial membranes. They probably play an important role in mitochondrial events such as the formation of pH and regulation of mitochondrial volume changes. Mitochondrial potassium and chloride channels could also be the targets for pharmacologically active compounds such as potassium channel openers and antidiabetic sulfonylureas. This review describes the properties, pharmacology, and current observations concerning the functional role of mitochondrial potassium and chloride channels.
PL
Korozja stalowych elementów zbrojenia w betonowych konstrukcjach jest poważnym problemem dotyczącym trwałości i bezpieczeństwa. Jednym z najbardziej agresywnych chemicznych składników powodujących taką korozję są jony chlorkowe działające poprzez ogólny mechanizm depasywacji powierzchni zbrojenia. Jony chlorkowe mogą dyfundować w roztworze w porach betonu docierając do zbrojenia, tak więc możliwość oszacowania współczynnika dyfuzji chlorków w betonie jest niezwykle ważna. Przedstawiona praca rozpoczyna serię trzech publikacji, których celem jest przegląd metod doświadczalnych wyznaczania współczynników dyfuzji jonów chlorkowych i teoretycznych modeli opisujących procesy transportu tych jonów w betonie. W szczególności, część 1 serii zawiera ogólne wprowadzenie do tematyki i omawia bardziej szczegółowo metody dyfuzyjne, część 2 koncentruje się przede wszystkim na metodach elektro-migracyjnych, a część 3 opisuje metody oparte na impedancji elektrochemicznej, które nie są obecnie tak powszechnie wykorzystywane do wyznaczania współczynników dyfuzji chlorków, jak wspomniane już dwie pozostałe grupy.
EN
The corrosion of steel reinfordcement (rebars) in concrete structures is a severe durability and safety problem. One of the most aggressive chemical species which induces such corrosion are the chloride ions via the general mechanism of depassivation of the rebar surface. Chloride ions can diffuse through the solution of pore system in concrete to reach the rebar, thus the assessment of the diffusion coefficient of chloride in concrete is of paramount importance. This paper starts a series of three papers which are meant to provide an overview of experimental methods and theoretical models of chloride diffusion in cement based materials. Specifically, Part 1 includes general introduction to the subject and covers pure diffusion methods, Part 2 deals with electro-migration methods, and finally Part 3 describes methods based on the electrochemical impedance which are not so common for chloride diffusion coefficient determination as the previous two groups.
EN
Chloride ion erosion in offshore environment may damage the mechanical properties of beam bridges. In this study, the reinforced concrete specimen was designed, accelerated erosion experiments were carried out to simulate the coastal corrosion environment, and the corrosion rate, nominal strength and equivalent strength of steel bars, concrete cracks and reliability of beam bridges were calculated to understand the time-varying mechanical properties of beam bridges. The results showed that the nominal and equivalent strength of reinforcing bars decreased with the increase of corrosion rate of reinforcing bars. The change of yield strength was greater than that of equivalent strength. The change of crack width of concrete showed a slow-fast-slow trend, and the reliability of beam bridges decreased significantly in about 50 years. The experimental results show that chloride ion corrosion can significantly damage the mechanical properties of the beam bridge and affect the time-varying reliability of the beam bridge. Therefore, it is necessary to carry out timely maintenance and inspection and take effective methods to control steel corrosion to ensure the safety of the use of the beam bridge.
PL
W pracy przedstawiono wyniki badań wyznaczania efektywnego współczynnika jonów chlorkowych w betonie o w/c = 0,3. Próbki betonu po 14 miesiącach twardnienia poddano 39-41 dniowemu wnikaniu jonów chlorkowych z 3% roztworu NaCl. Badania przeprowadzono na trzech rodzajach powierzchni: powierzchni górnej, powierzchni bocznej i ciętej. Największy efektywny współczynnik dyfuzji jonów chlorkowych (4,7⋅10-12 m2/s) otrzymano w przypadku wnikania chlorków do betonu od powierzchni formowanej, nieco mniejszy dla powierzchni zacieranej (4,2⋅10-12 m2/s), a najmniejszy (1,2⋅10-12 m2/s) dla powierzchni ciętej.
EN
The results of tests for determining the chloride ion effective diffusion coefficient in concrete with w/c = 0.3 were presented. Concrete samples after 14 months of hardening were subjected to 39-41 days ingress of chloride ions from 3% NaCl solution. The tests were carried out on three types of surfaces: top, side and sawn surface. The highest chloride ion effective diffusion coefficient (4,7⋅10-12 m2/s) was obtained in the case of chloride penetration into the concrete from the side surface, slightly smaller for the top surface (4,2⋅10-12 m2/s) and the smallest (1,2⋅10-12 m2/s) for the sawn surface.
PL
W artykule przedstawiono wyniki badań właściwości betonu na bazie cementu hutniczego CEM IIIA 42,5 N z dodatkiem popiołu lotnego. Ich celem było sprawdzenie możliwości zastosowania dodatku popiołu lotnego do betonu wykonanego na bazie cementu hutniczego w elementach konstrukcyjnych narażonych na działanie agresji chlorkowej niepochodzącej z wody morskiej. Analiza porównawcza otrzymanych wyników wskazała na znaczną poprawę szczelności oraz odporności na wnikanie jonów chlorkowych betonów zawierających dodatek popiołu lotnego. Jednocześnie minimalna wytrzymałość na ściskanie badanych betonów spełniała wymagania PN-EN 206:2014 dla klasy ekspozycji XD3. Betony zawierające dodatek popiołu lotnego wykazały wolniejsze tempo narastania wytrzymałości początkowej oraz bardzo dużą wytrzymałość w długim okresie dojrzewania. Wobec przedstawionych wyników badań, kwestią do rozważenia pozostaje wprowadzenie zamian w polskim systemie normalizacyjnym umożliwiających stosowanie dodatku popiołu lotnego do betonów wykonanych z zastosowaniem cementu hutniczego CEM IIIA 42,5. Rozwiązanie takie nie jest bowiem obecnie dopuszczalne w PN-EN 206:2014.
EN
The results of researches properties of concrete based on cement CEM IIIA 42,5 N with addition of fly ash were presented in the paper. The aim was the examination of the possibility of the fly ash applying to the concrete based on metallurgical cement in structural elements exposed to chloride aggression, which is not from sea water. Comparative analysis of the obtained results indicated a significant improvement of tightness and resistance to chloride ions penetration for the concretes containing fly ash addition. Simultaneously, in tested concretes, the conditions for minimum concrete strength required in the standard PN-EN 206:2014 for the exposure class XD3, were fulfilled. The concretes containing fly ash additive showed a slower rate of initial strength rise and high strength over a long period of maturation. In accordance to the presented research results, the point to consider is the introduction of changes in Polish standardization system allowing use of the additive of fly ash in the concrete made using cement CEM III A 42,5. Such a solution is not currently acceptable in PN-EN 206:2014.
EN
Ion channels selective for chloride ions are present in all biological membranes, where they regulate the cell volume or membrane potential. Various chloride channels from mitochondrial membranes have been described in recent years. The aim of our study was to characterize the effect of stilbene derivatives on single-chloride channel activity in the inner mitochondrial membrane. The measurements were performed after the reconstitution into a planar lipid bilayer of the inner mitochondrial membranes from rat skeletal muscle (SMM), rat brain (BM) and heart (HM) mitochondria. After incorporation in a symmetric 450/450 mM KCl solution (cis/trans), the chloride channels were recorded with a mean conductance of 155 ± 5 pS (rat skeletal muscle) and 120 ± 16 pS (rat brain). The conductances of the chloride channels from the rat heart mitochondria in 250/50 mM KCl (cis/trans) gradient solutions were within the 70–130 pS range. The chloride channels were inhibited by these two stilbene derivatives: 4,4′-diisothiocyanostilbene-2,2′-disulfonic acid (DIDS) and 4-acetamido-4′-isothiocyanostilbene-2,2′-disulfonic acid (SITS). The skeletal muscle mitochondrial chloride channel was blocked after the addition of 1 mM DIDS or SITS, whereas the brain mitochondrial channel was blocked by 300 μM DIDS or SITS. The chloride channel from the rat heart mitochondria was inhibited by 50–100 μM DIDS. The inhibitory effect of DIDS was irreversible. Our results confirm the presence of chloride channels sensitive to stilbene derivatives in the inner mitochondrial membrane from rat skeletal muscle, brain and heart cells.
PL
W artykule przedstawiono ocenę skuteczności naprawy podłogi, polegającej na odtworzeniu bariery ochronnej przed wnikaniem jonów chlorkowych w głąb podkładu betonowego. Naprawa taka może skutkować znacznym wydłużeniem oczekiwanego czasu użytkowania obiektu, również w sytuacji, gdy jony chlorkowe wniknęły już w beton w okresie poprzedzającym naprawę. Zastosowana metoda stanowi użyteczne narzędzie szacowania skuteczności wykonanej naprawy.
EN
The evaluation of efficiency of the parking floor repair has been presented in the paper. The repair consisted in restoring of continuity of the protective layer against the chloride ions ingress. Such repair can result in significant extension of the expected time of exploitation of the object, even if the chlorides have already penetrated the concrete substrate before repairing. The used method is useful tool for the estimation of effectiveness of the performed repair.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.