Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  biozgodność
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
Analizowano wpływ modyfikacji właściwości fizycznych i chemicznych implantów węglowych (włókien węglowych, kompozytów węgiel-węgiel) na ich zachowanie się w żywym organizmie.
EN
It was analysed the modification eh'ect of physical and chemicaĺ properties of carbon implants (carbon fibres, carbon-carbon composites) on their behaviour in a living organism.
2
60%
EN
Due to a shortage of donor heart in Japan, for end-stage congestive heart failure patients a demand to provide a better quality of life with the left ventricular assist system (LVAS) is strong. EVAHEART LAVAS uses a Japanese-made compact centrifugal pump, which can be implanted into a narrow thoracic cavity. This work has been a multi-institutional project carried out in collaboration with over 50 industrial companies in various technical disciplines, and it was financially supported mainly by a private fund as well as the Japan Science and Technology corporation (JST) fund. And the University of Pittsburgh Medical Center has contributed to the animal model evaluation since 1993. The pump flow performance was represented as head-flow (H-Q) relations, demonstrating that a blood pump flow of 8 l/min can be achieved at 100 mmHg at the pump speed of 2400 rpm. This performance should be sufficient as a clinical LVAS under most of practical conditions. The in vitro durability test was performed as a system as well as components. The results show a sufficient durability and reliability. A favorable biocompatibility with the blood contacting surface was confirmed by a series of animal experiments, which include eight long-term evaluations (90-180 days) in calves, with no serious problem such as thrombus formation or mechanical problems in recent cases. Various tests with the risk conditions have also been conducted, one of which is the hemolysis test with simulated seal defect conditions. The first clinical implantation of EVAHEART was conducted at Tokyo Women’s Medical University in May, 2005. Up to now, all three patients are in satisfactory hearth conditions.
3
Content available remote Kompozytowe retraktory tęczówki - badania wstępne
60%
PL
Przedstawiono wyniki badań wstępnych nad kompozytami włóknistymi, które będą wykorzystane do wytworzenia okulistycznych mikronarzędzi chirurgicznych w formie retraktorów tęczówkowych. Aktualnie do wytworzenia takiego narzędzia stosowane są czyste polimery, które przy bardzo małych przekrojach poprzecznych wyrobów są bardzo delikatne i często ulegają mechanicznemu uszkodzeniu. W pracy wytworzono serię materiałów kompozytowych, w których fazą zbrojącą były różne rodzaje włókien, takich jak naturalne (celuloza, jedwab), polimerowe (PAN) i biopolimerowe (Ca(Alg)2, Zn(Alg)2), a osnowę stanowiły dwa rodzaje żywic epoksydowych (E601 i E540). Sprawdzono ich właściwości fizykochemiczne, a także użytkowe w porównaniu z dostępnym produktem handlowym. Uformowane z kompozytów retraktory pokrywano cienką powłoką polimeru na bazie teflonu. Przeprowadzono ocenę mikroskopową powierzchni kompozytów (mikroskop stereoskopowy, mikroskop optyczny), zbadano ich parametry fizyczne (długość, średnica, kąt zakrzywienia), a także stabilność wytworzonych materiałów w warunkach in vitro (1 m-sc/37°C /H2O). W końcowej części eksperymentu przeprowadzono badania poręczności retraktorów, zakładając je na gałki oczne świni.
EN
The most popular retractors used in ophthalmology practice are made of plastics, usually nylon. Their main drawback is high stiffness of heads, which may cause many complications such as: damage of the iris constrictor, or iris atony (lack of reaction of the iris to a change in light intensity). The second group of materials used for the retractors is metals such as gold and titanium. Although they are easier to make required shapes, they could be dangerous due to their sharp tips which may cause iris rupture, lens capsule rupture or damage of corneal endothelium. Because of common incidence of eye affections requiring application of the iris retractors, much effort is put into investigations of new, biocompatible materials, which would be easy to apply during the operation, and on the other hand would minimise the risk of occurrence of post-surgery complications. The work presents preliminary results on fibrous composites which are planned to be used as elastic materials for production of ophthalmology microtools in the form of iris retractors. At present, for this purpose pure polymers are often used. The main drawback of such tools is their small cross section area, which makes them mechanically sensible, often resulting in their fracture. In this work number of composite materials containing various fibrous reinforcements such as natural fibres (cellulose, silk), polymer fibres (PAN), and biopolymer fibres (Ca(Alg)2, Zn(Alg)2) and two types of epoxy resins (E601, E540) as the composite matrix were prepared. Physicochemical properties of these composites, as well as their practical usefulness were compared to a commercially available polymer product. In order to provide suitable smoothness of the surface, and to improve bio-compatibility of the composites, the retractors were covered with a layer of teflon-based polymer. Surfaces of the composites were evaluated microscopically (stereoscopic microscope, optical microscope), and physically (length, diameter, angle of curvature). The last part of the research was an assessment of practical usefulness of the composite retractors by installing them in the pig eyeball.
4
Content available remote Polimery w medycynie
60%
5
Content available remote Korozja stopów dentystycznych w organizmie ludzkim
60%
|
2009
|
tom nr 11
502-503
PL
Jedną z funkcji, mających wpływ na biozgodność materiału jest czas przebywania konstrukcji w agresywnym środowisku płynów ustrojowych. Autorzy podjęli próbę określenia charakteru zmian w materiałach metalicznych, po długotrwałej implantacji w jamie ustnej. Celem pracy było określenie wpływu czasu użytkowania uzupełnień protetycznych na zmianę właściwości materiałowych stopów stomatologicznych. W zakresie tym mieszczą się metalograficzne badania mikroskopowe oraz mikroanaliza rentgenowska. Wstępna analiza wyników potwierdza szeroką aplikację implantacyjnej stali austenitycznej.
EN
One of the functions having the effect on biocompatibility of material is time of staying in aggressive environment of body fluids. The authors undertook an attempt to determine the nature of changes in the metallic materials after long-term implantation in the oral cavity. The aim of this work was to determine the effect of time of using the material in dental alloys. In this field there are metallographic microscopic examinations and X-ray microanalysis. Preliminary analysis of the results confirms such a wide spread of implantation austenitic steel.
PL
Nanorurki (NT) tlenku tytanu o długości około 1 ?m i średnicy w zakresie od 40 do 110 nm wytworzono na Ti metodą utleniania anodowego przy stałym potencjale (10, 15, 20 i 25 V) w roztworze gliceryny i wody dejonizowanej z dodatkiem 0,86% mas. fluorku amonu. Do scharakteryzowania samoorganizujących się porowatych warstw na Ti oraz wpływu temperatury wygrzewania w zakresie 200÷600°C na ich morfologię, strukturę i mechaniczną stabilność wykorzystano elektronową mikroskopię skaningową, elektronową mikroskopię transmisyjną, dyfrakcję rentgenowską oraz spektroskopię fotoelektronów. Na powierzchni termicznie stabilizowanych nanorurek TiO2 zaadsorbowano proteiny w celu wstępnej oceny biozgodności tak przygotowanych podłoży. Przeprowadzone badania wykazały, iż porowate warstwy tlenkowe uzyskiwały stabilność po wygrzewaniu w temperaturze powyżej 400°C, a ich struktura ulegała zmianie z amorficznej na krystaliczną (anataz + rutyl). Tak zmodyfikowana powierzchnia Ti okazała się obiecującym podłożem do adsorpcji protein w porównaniu z powierzchnią typowego implantu z czystego Ti.
EN
Titanium oxide nanotube arrays were fabricated in a mixture of glycerol, deionized water and low concentration solution of NH4F (0.86 wt %). Well- -ordered nanotube arrays of titania with length of ~1.0 ?m and diameter of about 40÷110 nm were prepared via electrochemical oxidation at constant voltage (10, 15, 20 or 25 V). SEM, X-ray diffraction, FTIR spectroscopy and XPS surface analytical technique were used to characterize the self-organized porous layers, and the effect of annealing at 200÷600°C on their morphology, structure and mechanical stability. Thermally stabilized TiO2 nanotubes were used for adsorption of the protein on their surfaces. Our results showed, that the nanotubular structure was stable above the 400°C and their structure changed from amorphous to the crystalline phase (anatase + rutile). Surface of Ti modified as presented in the article appeared a promising substrates for protein adsorption, as compared to a typical Ti implant surfaces.
7
Content available remote Corrosion resistance of metallic implants used in bone surgery
51%
EN
Purpose: The purpose of the research was analysis of influence of mechanical damages on the implants’ surface made of Cr-Ni-Mo steel on the pitting corrosion resistance. Analysis was performed for implants after different time of implantation applied for stabilization of the funnel chest and for stabilization bone fractures, as well as for intramedullary nails in the initial state. Design/methodology/approach: Research were performed on three groups of implants after different implantation time. Research were based on the potentiodinamic tests by recording the anodic polarization curves. The tests were performed in the Tyrode’s physiological solution. Findings: The research effect was determination the corrosion potential Ecorr and breakdown potential Eb for three groups of implants after different time of implantation and different mechanical surface damages. On the basis of investigation it was stated that for all implants the breakdown potential was in the range of Eb = +549 – +1017 mV and the corrosion potential was in the range of Ecorr = -143 – +103 mV. Research limitations/implications: The obtained results can be applied to comparing the effects of possible postoperative complications. They also show the relation between the damage of surface layers and implantation time. The values of corrosion and breakdown potentials indicate good corrosion resistance of the applied austenitic stainless steel. Practical implications: The essential influence on the corrosion resistance had the time of implantation and size of surface damages. The results of research of implants made of Cr-Ni-Mo austenitic stainless steel presents that the steel was performed quality requirements for metallic biomaterials used for tested implants. Originality/value: The work presents the results of pitting corrosion tests for metallic implants made of Cr-Ni- Mo steel in the initial state and after different implantation time.
PL
Zastosowanie niskotemperaturowego procesu tlenoazotowania jarzeniowego stali 316L (00H17N14M2) umożliwia wytworzenie warstw powierzchniowych składających się z austenitu przesyconego azotem tzw. fazy S z powierzchniową strefą tlenku chromu. Proces ten zapewnia zachowanie dobrej odporności korozyjnej tzw. stali medycznej, a jednocześnie w znaczący sposób zwiększa odporność na zużycie przez tarcie. W artykule przedstawiono warunki wytwarzania warstw tlenoazotowanych, ich strukturę, topografię powierzchni i właściwości tj. odporność na zużycie przez tarcie, korozję oraz ich biozgodność w kontakcie z ludzkimi fibroblastami. Uzyskane wyniki wskazują, że proces niskotemperaturowego tlenoazotowania jarzeniowego umożliwia wzrost twardości stali 316L do około 1120 HV0,05 oraz jej odporności na korozję i w znaczącym stopniu odporności na zużycie przez tarcie. Wytworzenie warstwy tlenków chromu wpływa również korzystnie na biozgodność stali austenitycznej 316L.
EN
316 steel (00H17N14M2) was subjected to low-temperature glow discharge-assisted oxynitriding in order to produce surface layers composed of nitrogen saturated austenite, known as the S phase, with a near-surface chromium oxide zone. This process improves significantly the properties of the steel, in particular the corrosion resistance and the frictional wear resistance, which are properties important in medical applications. The paper is concerned with the technology of the oxynitrided layers, and describes their structure, surface topography and properties, such as frictional wear resistance, corrosion resistance and biocompatibility with human fibroblasts. The results obtained indicate that the low-temperature glow discharge-assisted oxynitriding increases the hardness of 316L steel to about 1120 HV0.05, improves its corrosion resistance, and in a significant degree, its frictional wear resistance. The chromium oxide layers in addition improve the biocompatibility of the steel.
PL
Powierzchnię stopu tytanu Ti-Al-Mn modyfikowano w celu polepszenia jego biozgodności. Metodą rozpylania magnetronowego nanoszono warstwy Ti-Si (10% at). Część próbek z powłokami Ti-Si dodatkowo utleniono w atmosferze powietrza, w celu wytworzenia warstw ceramicznych TiO₂ - SiO₂. Próbki stopu tytanu bez powłoki, stopu z powłoką tytanowo-krzemową oraz z powłoką tlenkową poddawano testom zanurzeniowym i potencjodynamicznym w 0,9% roztworze NaCI. Skład i mikrostrukturę powierzchni próbek przed i po testach badano, stosując rentgenowską analizę fazową (XRD-GID), mikroskopię świetlną (LM) i elektronową (SEM) oraz mikroanalizę rentgenowską (EDX). Badano pH roztworów soli fizjologicznej w trakcie testów zanurzeniowych oraz skład roztworów metodą ICP-AES po testach. Oceniano właściwości mikromechaniczne warstw na podstawie testów zarysowania. Stwierdzono, że najbardziej korzystne właściwości wykazywały stopy z warstwą ceramiczną, otrzymaną w wyniku utlenienia warstw Ti-Si.
EN
The surface of a titanium alloy, Ti-6AI-1Mn, was modified with magnetron sputtered Ti-10Si (at%) layers. Some specimens were addi-tionally oxidised to transform the Ti-Si layers into ceramic ones, composed of TiO₂ and SiO₂. Specimens with the metallic and ceramic surface layers and the unmodified reference were subjected to immersion tests and potentiodynamic polarisation tests in a 0.9% NaCl solution. Composition and microstructure of surfaces before and after the immersion tests were analysed by XRD-GID, light microscopy and SEM/EDX. The pH of the physiological salt solutions was periodically measured during the immersion test and their chemical composition after the tests was determined by ICP-AES. Micromechanical properties were evaluated on the basis of scratch tests. Specimens with the ceramic surface layers appeared to have the best chemical and mechanical properties.
10
Content available remote Carbon coatings for medical implants
41%
EN
Purpose: In this paper we report in vitro and in vivo results of Nanocrystalline Diamond Coatings which are used in medicine onto medical implants. The very important property of carbon coatings is the protection living organism against the metalosis. Different medical implants with complicated shapes are covering by Nanocrystalline Diamond Coatings by RF dense plasma CVD. Design/methodology/approach: 1) Material characterizations of deposited coatings have been evaluated by using: Transmission Electron Microscopy (TEM), Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), Auger electron spectroscopy (AES), micro X-Ray Spectroscopy and bend test 2) Biological investigation based on: (a) in vivo and (b) in vitro examinations as well (c) clinical investigations - contact allergy. Findings: It was revealed that Nanocrystalline Diamond Coatings form the barrier diffusion between implant and human environment as a consequence prevent leaching of metallic ions into the body. Additionally, the research on carbon coatings proved that diamond layers are biocompatible with living organism. Contact allergy on nickel is inhibited by diamond powders. Practical implications: Practical application metal implants with NCD in orthopedy, cardiosurgery, oral surgery, maxillo-facial surgery and dermatology. Originality/value: We have observed anti-inflammatory, antiallergic and anticancerogenic responses from the carbon coatings layers onto medical implants like wires and screws.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.