EN
Voltage transformers with different geometrical dimensions of the windings were covered with analysis of the influence of interferences from the magnetic component of the external electromagnetic field of frequency 50 Hz from neighbouring current track on the change of their errors and, as a result, on deterioration of their accuracy. Change of the metrological properties of the voltage transformers is condition on the geometrical dimensions of the primary and the secondary windings, therefore to transformer construction
PL
Przekładniki napięciowe o różnych konstrukcjach uzwojeń zostały objęte analizą wrażliwościową na zakłócenia, pochodzące od składowej magnetycznej zewnętrznego pola elektromagnetycznego o częstotliwości 50 Hz pochodzącego od pobliskiego toru prądowego, powodującego w określonych okolicznościach zmianę warunków pracy układu uzwojeń przekładnika i w rezultacie wzrost wartości jego błędów. Zmiany właściwości metrologicznych przekładnika napięciowego w decydującym stopniu zależą od wymiarów geometrycznych uzwojenia pierwotnego i wtórnego przekładnika, czyli od jego konstrukcji.
PL
W artykule przedstawiono koncepcję opracowanego układu pomiarowego do wyznaczania wartości błędów prądowego i kątowego transformacji harmonicznych prądów odkształconych przez indukcyjne przekładniki prądowe. Badania szerokopasmowej dokładności przeprowadzono dla trzech wybranych seryjnie produkowanych indukcyjnych przekładników prądowych. Wartości błędów kątowego i prądowego transformacji wyższych harmonicznych mogą przyjmować wartości mniejsze niż zdefiniowane w normie PN-EN IEC 61869-6 wartości graniczne błędów odpowiednich klas dokładności przekładników małej mocy.
EN
In the paper the concept is presented of the developed measuring system to determine the values of current and phase errors for transformation of harmonics of distorted currents by inductive current transformers. The wideband accuracy tests were performed for three selected inductive current transformers. The values of current and phase errors of the transformation of higher harmonics may have lower values than the limits defined in the standard PN-EN IEC 61869-6 for the corresponding accuracy classes of low-power instrument transformers.
PL
Przedmiotem artykułu są zagadnienia związanie z analizą właściwości metrologicznych indukcyjnych przekładników napięciowych podczas transformacji sygnałów sinusoidalnych o częstotliwościach 50 Hz i wyższych. Wyniki tych badań pozwolą między innymi wstępnie określić wpływ badanego przekładnika na dokładność wyznaczania w układzie pośrednim wartości współczynnika THDU wykorzystywanego do określenia jakości energii elektrycznej oraz ocenę dokładności przekładnika podczas transformacji zaburzeń przewodzonych oraz sygnałów odkształconych.
EN
This paper presents analysis of metrological properties of inductive voltage transformers (VT) in conditions of transformation of sinusoidal signals of frequencies 50 Hz and higher. The results of these studies are useful in determining the impact of tested VT on designated, in indirect measuring system, values of total harmonic distortion factors (THDU) and its accuracy of transformation of conductive disturbances and distorted signals.
4
Content available remote Właściwości metrologiczne przekładnika prądowego wyższych częstotliwości
100%
PL
W artykule przedstawiono wyniki analiz właściwości metrologicznych pomiarowego indukcyjnego przekładnika prądowego wyższych częstotliwości i klasycznego przekładnika prądowego o częstotliwości znamionowej 50 Hz podczas transformacji sinusoidalnych prądów o częstotliwościach od 50 Hz do 20 kHz przeprowadzone w oparciu o częstotliwościowe charakterystyki błędów prądowego i kątowego wyznaczone w opracowanym układzie pomiarowym.
EN
In the paper the results of analysis of the metrological characteristics of the measuring wide band inductive current transformer and typical inductive current transformer designed for accurate transformation of the 50 Hz frequency sinusoidal currents during the transformation of sinusoidal currents at frequencies from 50 Hz to 20 kHz are presented. Conclusions are based on the frequency characteristics of current errors and phase displacement designated in developed measuring system.
EN
The aim of the research is to determinate the influence of sinusoidal conductive disturbances on current error and phase displacement of the CT with Ni80Fe20 toroidal core.
PL
Celem badań jest określenie wpływu sinusoidalnych zaburzeń przewodzonych na wartości błędów prądowego i kątowego badanego przekładnika prądowego z rdzeniem toroidalnym wykonanym z permaloju Ni80Fe20.
PL
W ocenie jakości energii elektrycznej ogromne znaczenie mają cechy metrologiczne przekładnika, czyli wartości jego błędów napięciowego i kątowego [1]. W artykule zostały przedstawione zastosowane metody pomiarowe oraz wyniki przeprowadzonych analiz umożliwiające określenie dokładności przekładników napięciowych podczas pomiaru napięć odkształconych. Stwierdzono, że podczas takich pomiarów następuje pogorszenie właściwości metrologicznych przekładników napięciowych, co prowadzi do zmniejszenia ich dokładności przy ocenie jakości energii elektrycznej.
EN
Metrological properties of a measuring transformer such as a voltage error and phase displacement are of significant importance in assessment of electric power quality both in steady and transient state [1]. In the paper the method and results of laboratory investigations of the voltage transformer accuracy during measurements of non-sinusoidal voltages are presented. The laboratory tests based on two medium-voltage transformer models and a voltage transformer of type UDZ 24 produced by ABB company were carried out in the measuring circuit shown in Fig. 1. The measurements were taken in the full range of supply voltages and loads of the secondary winding of the voltage transformers in accordance with the standard for determining the accuracy of the inductive voltage transformers [4]. The voltage error and phase displacement of the voltage transformer determined for measurements of non-sinusoidal voltages, shown in Figs. 2 - 5, were compared with the corresponding errors measured for sinusoidal voltages (presented in Table 1). The influence of the conductive disturbances on the voltage transformer errors was determined as the differences between these values. The results of the laboratory investigations show that the metrological properties of a voltage transformer were worse when it was used for measurements of non-sinusoidal voltages. The increase in errors results in the decrease in the accuracy of the power quality determination. In some cases this worsening of the metrological properties causes the decrease in the voltage transformer accuracy class [4].
7
Content available remote Błędy elektronicznych przekładników prądowych
80%
PL
Wpływ częstotliwości mierzonego sygnału na właściwości metrologiczne elektronicznych przekładników prądowych producenci charakteryzują za pomocą charakterystyk częstotliwościowych błędu prądowego oraz błędu kątowego, wyznaczonych za pomocą sinusoidalnego sygnału testującego. Przedmiotem referatu jest opis analityczny tych błędów. W referacie zaprezentowano również sposób wykorzystania zależności na ww. biedy do opisu sygnału wyjściowego przekładników mierzących przebiegi odkształcone.
EN
The frequency of measured signal influencing metrological properties of the electronic current transducers is characterized by the frequency characteristics of current error and angle error. These frequency characteristics are obtained by the sinusoidal testing signal This paper takes into consideration analytical description of these errors. The way of using above errors to description of output signal of transducer sensing deformed signals have also received investigation.
EN
Instrument transformers should maintain their metrological properties when measured voltages and currents are sinusoidal as well as when they are distorted. The aim of the research was to determine the influence of the change of the primary voltage and load of the voltage transformers on the degree of interaction of the sinusoidal conductive interferences (200 Hz – 9000 Hz) on their metrological properties.
PL
Scharakteryzowanie metrologicznych właściwości przekładnika prądowego podczas transformacji sinusoidalnych prądów o podwyższonych częstotliwościach oraz sygnałów odkształconych zawierających wyższe harmoniczne wymaga wyznaczenia charakterystyk zmian błędów prądowego i kątowego badanego przekładnika wraz ze zmianą częstotliwości transformowanego prądu pierwotnego dla zadanych procentowych wartości znamionowego prądu pierwotnego i obciążenia uzwojenia wtórnego.
EN
Determine of the metrological properties of the current transformer (CT) during transformation of sinusoidal currents of frequency above 50 Hz and distorted signals which contain higher harmonics requires designation of its characteristics of current error and phase displacement changes with a primary signal frequency increase for the given percentage of rated primary current and secondary winding load. (Studies of the inductive current transformer with Ni80Fe20 toroidal core transformation characteristics designated for sinusoidal currents of frequency 50 Hz - 20 kHz).
PL
Częstotliwościowe pasmo pracy indukcyjnych przekładników prądowych może wynosić kilka kiloherców, jest zatem odpowiednie do transformacji harmonicznych prądu podczas pomiarów energii elektrycznej i oceny jej jakości. Jednak problem zbyt niskiej dokładności transformacji może wciąż wynikać z nieliniowości charakterystyki magnesowania ich rdzenia magnetycznego i dodatkowego odkształcenia prądu wtórnego szczególnie harmonicznymi niższego rzędu: 3., 5. i 7. W artykule przedstawiono wyniki badań dotyczące zjawiska generacji przez indukcyjne przekładniki prądowe harmonicznych prądu wtórnego. Ponadto, omówiono ich wpływ na dokładność transformacji poszczególnych harmonicznych odkształconego prądu pierwotnego o częstotliwości podstawowej 50 Hz.
EN
The frequency range of operation of inductive current transformers may reach several kilohertz, therefore they are suitable for the transformation of current harmonics, when measuring electrical power and for evaluation of its quality. However, the problem of low transformation accuracy may still result from the non-linearity of the magnetization characteristics of their magnetic core and additional secondary current distortion, especially with the lower order harmonics: 3, 5 and 7. The article presents the results of research on this phenomenon. Moreover, their influence on the transformation accuracy of individual harmonics of the distorted primary current with a fundamental frequency of 50 Hz is discussed.