Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  autokalibracja
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote A voltage divider with autocalibration – a version with single compensation
100%
EN
This paper presents the results of experimental and simulation studies of a divider with the autocalibration functionality, a version with single compensation when the voltage is lowered to 230 Vrms. Based on the results of simulation studies for the standard voltage of a 15 kVrms distribution line, design recommendations for a divider for this voltage were formulated.
PL
Przedstawiono wyniki badań eksperymentalnych oraz symulacyjnych dzielnika z funkcjonalnością autokalibracji w wersji z pojedynczą kompensacją przy obniżonym napięciu do 230Vrms. Na bazie wyników badań symulacyjnych dla standardowego napięcia linii dystrybucyjnej 15kVrms sformułowano zalecenia konstrukcyjne dzielnika dla tego napięcia.
PL
Artykuł dotyczy problemu wpływu rozrzutu procesu technologicznego na parametry wysokoczęstotliwościowych scalonych układów RF do komunikacji bezprzewodowej. Dla zilustrowania skali tego wpływu, przedstawiono wyniki własnych symulacji niektórych bloków funkcjonalnych stosowanych w nadajniku/od bioniku (transceiver) dla technologii CMOS 0,35μm. Następnie, na podstawie najnowszej literatury omówiono wybrane, układowe metody automatycznego dostrajania (autokalibracji) parametrów syntezera częstotliwości z pętlą PLL, wejściowego wzmacniacza niskoszumnego LNA oraz mieszaczy z przemianą bezpośrednią i z częstotliwością pośrednią.
EN
The paper deals with impact of process variations on parameters of high frequency RF integrated circuits for wireless communication. To illustrate the scale of this impact some results of own simulation of selected functional blocks used in transceivers for CMOS 0.35 μm process were presented. Next, basing on recent publications the chosen methods of automatic tuning (self-calibration) of main parameters of frequency syntesizer with PLL, input low noise amplifier and down - conversion mixers using dedicated on-chip circuits, are reviewed.
3
Content available remote A voltage divider with autocalibration – a review of structures
100%
EN
This article presents a method of autocalibrating a voltage divider and the measurement properties of systems in which it is realised in the active, passive and compensating versions. Autocalibration refers to the ability of a measurement system to determine its parameters where and when it is operating, using an unknown measured signal as the only activation of the procedure.
PL
Artykuł przestawia metodę autokalibracji dzielnika napięcia oraz właściwości metrologiczne układów ją realizujących w wersjach: aktywnej, pasywnej oraz kompensacyjnej. Przez autokalibrację określa się zdolność układu pomiarowego do wyznaczania swoich parametrów w miejscu i w trakcie pracy przy wykorzystaniu nieznanego mierzonego sygnału jako jedynego pobudzenia procedury.
4
Content available Multiaxial transducers calibration
84%
EN
The aim of present article is investigating properties of accelerometer calibration method, called automatic calibration. The research of transducer's model was conducted and chosen optimization algorithms were rated by the simulation method and also using real transducer. The aim of tests was examination of the possibility to find parameters of the transducer model considering influence of temperature and deviation of axes. Described optimal calibration process without special calibration apparatus considers also influence of temperature on acceleration measurement. Afterward, described calibration method was tested on real transducer. Obtained results show that the hybrid two-step algorithm is suitable to the multiaxial transducers calibration. In the research, accelerometer as triaxial transducer was chosen and subjected to tests and the results of simulation was recorded in the MATLAB workspace. From existing estimation, three algorithms were chosen: the quasi-Newton, simplex (Nelder-Mead), and Levenberg-Marquard. The experimental part of the calibration utilized the idea of using existing and known constant vector of the measured value like gravitational acceleration and magnetic field. Calibration with temperature compensation of real transducer was presented.
5
Content available remote Kaskadowy dzielnik napięcia z autokalibracją - podstawy teoretyczne
84%
PL
W pojedynczym układzie kondycjonującym z autokalibracją, który obniża mierzone wysokie napięcie do wartości akceptowanych przez współczesne przetworniki A/C, wykorzystywana jest zależność, która dla dużej wartości podziału napięć ma bardzo niekorzystne uwarunkowanie numeryczne. Powoduje to duże błędy identyfikacji tej stałej. Wersja kaskadowa układu eliminuje tę wadę. Metodą indukcji matematycznej wykazano, że najmniejsze błędy identyfikacji uzyskuje się, gdy wszystkie segmenty kaskady mają identyczną stałą podziału napięć.
EN
The one segment voltage conditioning circuit with autocalibration that reduces high voltages to the values accepted by contemporary AD converters is characterized by an unfavorable condition number of an equation used during identification procedure. The cascade version of the divider eliminates this disadvantage and considerably reduces identification error. The lowest identification error occurs for the same voltage ratio of each segment of the cascade.
6
Content available remote Amplitude comparator for self-calibration circuit of IR mixer
84%
EN
This paper presents a new sequential amplitude comparator of two sinusoidal signals. It was designed for calibration circuit of phase shifters leading to better suppression of image component in the signal path of 2.4 GHz receiver. The experimentally obtained values of IRR above 45dB after calibration process indicate that image signal rejection is very good. It enables to conclude that the conception and design of amplitude comparator is suitable. The design was performed using SiGe 0,35nm BiCMOS process.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.