Anodic potentiodynamic polarization of dehydrogenated LaNi4.5Co0.5 compact electrode at very slow potential scan rate has been applied to evaluate material corrosion rate in 6 M KOH within passive region. Chronoamperometric measurements carried out at E = –0.2 V (HgO/Hg) allowed to obtain steady state anodic current of electrode passivation which corresponds to alloy stationary corrosion rate. It has been shown that corrosion rate determined in such a way is in very good agreement with alloy initial corrosion rate found on the basis of capacity fade of powdered, composite electrode prepared from this material.
PL
Do oceny szybkości korozji pozbawionej wodoru litej elektrody LaNi4.5Co0.5 w 6 M roztworze KOH zastosowano technikę potencjodynamicznej polaryzacji przy bardzo powolnym skaningu potencjału. Pomiary chronoamperometryczne wykonane przy E = –0,2 V (HgO/Hg) pozwoliły znaleźć ustaloną wartość prądu anodowego pasywacji elektrody, który odpowiada stacjonarnej szybkości korozji. Pokazano, że szybkość korozji wyznaczona w ten sposób jest w bardzo dobrej zgodności z początkową szybkością korozji znalezioną na podstawie spadku pojemności proszkowej, kompozytowej elektrody wykonanej z tego materiału.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Wodór może wnikać do żelaza lub stali przy potencjałach anodowych, jeśli odsłaniana jest czysta powierzchnia metalu np. w wyniku rozrywania warstewki powierzchniowej podczas korozji naprężeniowej. Szybkość przenikania wodoru (SPW) przez żelazną membranę o grubości 35 nm badano metodą elektrochemiczną w 0,1 M NaOH podczas polaryzacji katodowej i anodowej w 25oC. Szybka anodowa polaryzacja powodowała chwilowy wzrost SPW, który zachodził nawet podczas spadku prądu anodowego. Zwiększoną SPW można przypisać zakwaszeniu z powodu anodowego utleniania żelaza. Zaproponowano, że wzrost SPW podczas spadku prądu anodowego może być wytłumaczony tworzeniem słabo ochronnych warstw, które hamują dyfuzję protonów od powierzchni metalu.
EN
Hydrogen can enter into iron or steel at anodic potentials when bare metal is exposed, e.g. by film rupture during stress corrosion cracking. Hydrogen permeation rate (HPR) through a 35 nm thick iron membrane was studied with the electrochemical technique in 0.1 M NaOH during cathodic and anodic polarisations at 25oC. Fast anodic polarisation resulted in transients of enhanced HPR which continued to rise despite of decaying anodic current. The enhanced HPR can be ascribed to acidification due to anodic oxidation of iron. It is proposed that the continued rise of HPR during anodic current decay can be explained by the formation of low-protective layers which hinder diffusion of protons out of the metal surface.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Za pomocą trzech komplementarnych metod elektrochemicznych oceniono zdolność pochłaniania wodoru przez stopy LaNi4,8Bi0,2 i LaCo4,8Bi0,2 w wyniku ekspozycji katodowej w 6M KOH. Obecność kobaltu w stopie powoduje wzrost gęstości prądu anodowego próbki niewodorowanej, co oznacza pogorszenie zdolności stopu do pasywacji. Stop LaCo4,8Bi0,2 charakteryzuje się jednak większą efektywnością pochłaniania wodoru a także większym prądem wymiany układu H2O/H2 w porównaniu do stopu LaNi4,8Bi0,2.
EN
The hydrogen absorption ability at LaNi4,8Bi0,2 and LaCo4,8Bi0,2 alloys during their cathodic exposure in 6M KOH solution has been evaluated using three complementary electrochemical methods. The presence of Co in alloy causes increase of anodic current density of as received sample and, thus worsens the passivating properties of the alloy. The LaCo4,8Bi0,2 alloy is capable to absorb greater amounts of hydrogen and it also exhibits higher exchange current for H2O/H2 system in comparison to LaNi4,8Bi0,2 alloy.