W opracowaniu przedstawiono model symulacyjny cyfrowego impedancyjnego lokalizatora zwarć z algorytmem pomiarowym wykorzystującym równania pętli zwarciowej dla wartości chwilowych prądów i napięć oraz model fragmentu systemu elektroenergetycznego z wydzieloną linią przemysłową do badań. Przeprowadzono ocenę dokładności lokalizacji zwarć w funkcji rezystancji przejścia, obciążenie linii, miejsca i rodzaju zwarcia. Podkreślono wpływ asymetrii sieciowej na dokładność obliczeń. Oceniono także dynamikę procesu estymacji odległości do zwarcia.
EN
The paper presents simulation model of digital reactance fault locator with measuring algorithm using equastions of the short circuit for instantaneous values of voltage and current as well as a model of part of power electric system with a transmission line selected for research. Estimation of accuracy of fault localization as a function of fault resistance, line load, location position and kind of the fault was carried out. It perform estimate of dynamics of measurement of distance for damage also.
W celu zapewnienia prawidłowej pracy układów elektroenergetycznej automatyki pomiarowej i zabezpieczeniowej dla przypadków silnie zakłóconych wejściowych sygnałów pomiarowych przy jednoczesnym szerokim zakresie zmian częstotliwości ich składowej podstawowej, konieczne jest zastosowanie algorytmów adaptacyjnych częstotliwościowo, dostosowujących swoje właściwości do zmiennych cech sygnałów wejściowych odwzorowujących zmiany zachodzące w zabezpieczanym obiekcie. Opracowanie jest kontynuacją tematu rozpoczętego w poprzednium wydaniu pisma.
EN
The strong distorted input measurement signals can be expected under many working conditions of power system protection devices. Additionally the frequency of fundamental component of input measurement signals can be changed in the wide range. Thus for the proper functioning of such protection devices in all operating conditins it is necessary the using of adequate measurement and protection algorithms which can adapt their proprieties to the input signals character. In this paper frequency adaptive algorithms are presented.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The signals that characterize the work of an electric arc furnace are important not only for the electric circuit power control and electrode position control but also for control of the injections of coal in the foaming slag system. Taking into account above requirements, there is important to choose proper measurement signals. Measurement only electrical signals are not sufficient for control systems. For proper control of electrodes knowledge about their positions is also important. For data acquisition a special system was constructed. The system consists of portable computer with acquisition card, conditioning system with differential amplifiers, antialiasing filters and sample and hold circuits. The system software makes possible on-line observation of measured signals and save data to hard disk. After measurement information obtained in no-load state, three two-phase short circuits and three-phase short circuits tests were used in compensation algorithm for calculation the circuits parameters and describing real arc voltages. Positions of electrodes were calculated from recorded electrode speeds. Next all data were analysed off-line to determine arc model parameters and to define control system states. In the paper some interesting phenomena observed in furnace control system are presented.
PL
Sygnały, które charakteryzują pracę elektrycznego pieca łukowego są istotne nie tylko do sterowania mocą obwodu elektrycznego i położeniem elektrod, ale również do sterowania wdmuchiwaniem węgla przy pienieniu żużla. Rozważając powyższe wymogi, ważnym jest wybór odpowiednich sygnałów pomiarowych. Pomiar tylko sygnałów elektrycznych nie jest dostateczny dla systemu sterowania. Dla właściwego sterowania elektrodami ważna jest także informacja o ich położeniu. Wcelu zdobycia danych został zbudowany specjalny system. System złożony jest z przenośnego komputera, wyposażonego w kartę do gromadzenia danych, systemu wzmacniania ze wzmacniaczami różnicowymi, filtrów przeciwzakłóceniowych i obwodów próbkowania i podtrzymywania. Oprogramowanie systemu umożliwia obserwacje on-line mierzonych sygnałów i zapis danych na dysku twardym. Po informacji pomiarowej uzyskanej ze stanu jałowego, wykonywane są trzy dwufazowe i trójfazowe testy zwarcia w celu kompensacji algorytmu obliczeń parametrów obwodu i opisu rzeczywistej wartości napięć łuku. Pozycje elektrod obliczone są na podstawie zarejestrowanych prędkości. Następnie wszystkie dane są analizowane off-line, w celu określenia parametrów modelu łuku i zdefiniowania stanów systemu sterowania. W artykule przedstawiono niektóre interesujące zjawiska zaobserwowane w systemie sterowania piecem.