Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  air purification
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Thermal-catalytic oxidation of waste gases
100%
EN
Waste gas can be neutralized by catalytic or thermal oxidn., depending on the waste gas hydrocarbon content. Catalytic oxidn. of waste gas is often preceded by pre-heating to a given temp. A thermal-catalytic oxidn. of waste gas consists in flame pre-heating to a working temp. of the catalyst bed. In this method, a flame is a heat source and a source of radicals and some intermediate oxidn. products which accelerate and promote oxidn. of waste gas toxic components. The effect of flame gas pre-heating of a thermal-catalytic reactor on oxidn. efficiency for a waste gas is discussed. Design of a surface streaming-diffusive burner and its oxidn. efficiency are also described. Such a burner enlarges the surface of contact between the flame and waste gas and increases the intensity of combustion zone gas mixing.
PL
Proces neutralizacji gazów odpadowych, w zależności od zawartości w nich węglowodorów, przeprowadza się metodą katalitycznego lub termicznego dopalania. Proces katalitycznego dopalania wymaga często wstępnego podgrzewania gazu odpadowego do określonej temperatury. Płomieniowe podgrzewanie gazu odpadowego w katalitycznym dopalaczu stanowi istotę termiczno-katalitycznej metody utleniania gazów odpadowych. W metodzie tej płomień wykorzystano nie tylko jako źródło ciepła, ale także jako źródło rodników i aktywnych pośrednich produktów utleniania ułatwiających i przyśpieszających procesy unieszkodliwiania toksycznych składników gazu odpadowego. Przedstawiono wpływ realizacji płomieniowego podgrzewania gazu odpadowego w dopalaczu termiczno-katalitycznym na skuteczność procesu utleniania. Opisano także konstrukcję palnika powierzchniowego typu strumieniowo-dyfuzyjnego i wyniki badań efektywności jego działania. Konstrukcja tego palnika zapewnia dużą powierzchnię kontaktu płomienia z przepływającym gazem odpadowym oraz zwiększa intensywność mieszania gazu odpadowego w strefie spalania.
|
2010
|
tom nr 10
443-448
PL
Kolejna część cyklu publikacji poświęconych problematyce oczyszczania powietrza. Tematem artykułu jest eksploatacja filtrów stosowanych do oczyszczania powietrza w instalacjach klimatyzacji i wentylacji. W jego części pierwszej („TCHK”, nr 8/2010) omówiona została m. innymi charakterystyka techniczna stosowanych filtrów strony nawiewnej, którymi są: filtry wstępne, filtry dokładne i filtry końcowe – absolutne. W części drugiej materiału przedstawiono filtry strony wyciągowej. Zwrócono uwagę na ocenę stanu technicznego filtrów, a także ważny problem ich wymiany, w tym ochronę zdrowia personelu dokonującego takich operacji. W końcowej części artykułu przedstawiono klasyfikację pomieszczeń czystych.
EN
This is the next paper dealing with the problem of air cleaning. The topic is the maintenance of air cleaning fitters installed in air conditioning and ventilating systems, in the first part (JCHK'. nr 8/2010) the fresh air primary filters, fine filters and absolute filters have been characterized. The second part deals with exhaust air filters. The problems of evaluation of filters technical condition and the procedures of their replacement are discussed. At the end the classification of clean rooms is given
|
2012
|
tom Nr 4
86-92
PL
W części drugiej artykułu omówiono poszczególne stopnie filtracji strony nawiewnej instalacji klimatyzacji i wentylacji oraz strony wywiewnej. Zaproponowano zastosowanie określonego stopnia filtracji powietrza w zależności od przeznaczenia pomieszczenia służby zdrowia. Opisano ponadto: rozkład zanieczyszczenia mikrobiologicznego powietrza w przykładowej instalacji klimatyzacyjno-wentylacyjnej sali operacyjnej oraz kryteria oceny stanu zanieczyszczenia filtrów. Z uwagi na zagrożenia występujące podczas wymiany filtrów powietrza instalacji szpitalnych omówiono również zagadnienie ochrony zdrowia personelu wykonującego te prace.
EN
The second part of the paper covers particular filtration levels of the air-supply outlet as well as air-exhaust outlet of the air-conditioning and ventilation fittings. A particular filtration level has been recommended depending on the purpose of the room at a given medical facility. Moreover, the following information has been provided: distribution of microbiological contamination in a reference air-conditioning and ventilation system in an operating room, including the assessment criteria for filter contamination. With respect to risks related to filter exchange of hospital systems, the question of health protection at workplace has also been discussed.
4
Content available remote Removal of ammonia from air by fibrous ion exchangers
63%
EN
The paper presents the results of laboratory studies of ammonia sorption from air by fibrous ionexchange materials containing acidic groups in concentration of 3-5 mmoles per gram as a function of the ammonia concentration (3-30 ppm), relative air humidity, air flow rate and the thickness of filtering layer. It follows from our experiments that non-woven fabrics with the thickness of above 2 mm and surface density of -0.3 kg m(-2) can efficiently reduce ammonia concentration in air to <1 ppm at flow rates of <0.2 m s-1. The sorbent can be regenerated with acid solution to obtain salts that can be used as mineral fertilizers.
EN
Formaldehyde is known to be ubiquitous pollutant in an atmospheric environment. It enters the atmosphere from natural processes such as: biomass combustion, metabolic processes and from direct human sources -fuel combustion (automotive, power plants and waste incinerators) and industrial emissions (occurring during production, use and storage of formaldehyde). Formaldehyde is also formed in photochemical oxidation of methane and other volatile organic compounds including natural and anthropogenic ones, like: alkanes, alkenes, aldehydes and alcohols. Acting as a source of radicals in the atmosphere and precursor of ozone, peroxyacetyl nitrate and nitric acid formation, formaldehyde is an important contributor to photochemical smog in urban air. Although natural direct emissions and secondary production seem to be larger than direct anthropogenic releases, the highest levels of formaldehyde concentrations occur near anthropogenic sources. Concentrations of formaldehyde in clean rural air are usually below 1,5 ug/m3 and about 20 ug/m3 in urban areas. Formaldehyde is a major intermediate product in chemical manufacturing. Its main uses are the production of phenolic, urea, melamine and polyacetals resins, which are widely used as adhesives and binders in wood, textile, pulp and paper industries. Formaldehyde is also used as a preservative, disinfecting and cleaning agent in many products used in daily life. Building, decorating and insulating materials, furniture, wooden floors, carpets and textile garments are significant formaldehyde emissions sources in indoor areas. In addition formaldehyde in homes is released (about 10-30%) from combustion processes (tobacco smoking, fireplaces and furnaces). Due to the widespread distribution of formaldehyde sources in houses, average levels of its concentrations in indoor air are 20-60 ug/m3 and are usually evaluated according to limits of formaldehyde concentration. Formaldehyde even at low exposure levels causes burning sensations in the eyes, nose and throat, and contributes to sick house syndrome. Long-term exposure induces sensitization to formaldehyde which may develop an allergic reaction. Formaldehyde was a suspected carcinogen and an established 2A group in the International Agency for Research on Cancer (IARC) classification system until 2004, when the working group of IARC reclassified it as a human carcinogen (1G). According to the toxicity and exposure levels of formaldehyde, there is the necessity to take measures to reduce formaldehyde concentrations in indoor air. There are some simple ways of limiting its emission, i.e. buying wood products, furniture and decorating materials with low formaldehyde content, ensuring adequate ventilation, temperature moderation and reduction of humidity levels. The most effective solution is air cleaning which is recently becoming more popular. There are some general methods of air purification like adsorption of formaldehyde on activated carbon or other adsorbents with functional groups reactive to formaldehyde (usually primary and secondary amine groups), and an alternative technique-oxidation, including: heterogonous catalytic oxidation with air, photocatalytic degradation and oxidation of formaldehyde using potassium permanganate filters.
6
Content available remote Possibilities of using ligninolytic fungi for biological waste gas treatment.
51%
EN
The possibility of using wood-destroying fungi (Phanerochaete chrysosporium and Trametes versicolor) to remove selected org. pollutants from waste gas was studied using toluene, chlorobenzene, tetrachloromethane, aniline, Bu alc., and Et acetate. Expts. were performed in 2 types of purifn. systems: a lab. biofilter filled with a straw/peat mixt. and inoculated with a mycelium; and a bioreactor contg. a fungal biomass immobilized on polyethylene support and filled with a nutrient-rich (growth) medium or a N-deficient (induction) medium. Depletion of toluene and chlorobenzene was not obsd. in the biofilter. In the bioreactor filled with induction medium, Phanerochaete chrysosporium degraded chlorobenzene at the rate of 1.7 mg/m3-s; this system also removed tetrachloromethane. At low influent concns. of tetrachloromethane (120 mg/m3), removal efficiency reached 100%; however, at high concns. (1720-2680 mg/m3), efficiency approached 40%, and a max. elimination capacity of 2.25 mg/m3×s was obsd. Best biofilter performance was obsd. when Bu alc. was degraded by Phanerochaete chrysosporium (elimination capacity, 7.35 mg/m3-s; removal efficiency, 93.8%). Biofilter removal of waste gas aniline with Trametes versicolor also occurred (elimination capacity, 1 mg/m3-s; removal efficiency, 74-96%).
PL
Zbadano możliwość wykorzystania grzybów rozkładających drewno (Phanerochaete chrysosporium i Trametes versicolor) do oczyszczania gazów z wybranych zanieczyszczeń organicznych (toluenu, chlorobenzenu, tetrachlorometanu aniliny, butanolu, octanu etylu). Badania wykonano w dwóch typach układów oczyszczających: w biofiltrze laboratoryjnym wypełnionym mieszanką słomy i torfu, zaszczepionych grzybnią, oraz w bioreaktorze z biomasą immobilizowaną na nośniku polietylenowym, wypełnionym pożywką bogatą w składniki odżywcze (wzrostową) lub o niskiej zawartości azotu (indukcyjną). Biofiltr nie usuwał toluenu i chlorobenzenu, podczas gdy bioreaktor z Phanerochaete chrysosporium na pożywce indukcyjnej usuwał chlorobenzen z szybkością 1.7 mg/m3-s . Układ ten oczyszczał również gaz z tetrachlorometanu. Gdy stężenia początkowe tetrachlorometanu były małe (120 mg/m3), stwierdzono 100% skuteczności oczyszczania, natomiast, gdy stężenia były duże (1720-2680 mg/m3), skuteczność dochodziła do 40%, a maksymalna szybkość oczyszczania wynosiła 2.25 mg/m3×s . W biofiltrze najefektywniej butanol usuwał grzyb Phanerochaete chrysosporium (szybkość oczyszczania 7.35 mg/m3-s, a skuteczność 93,8%). Stwierdzono również oczyszczanie gazów z aniliny na złożu z Trametes versicolor (szybkość 1 mg/m3-s; skuteczność, 74-96%).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.