Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  active and reactive power
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper deals with a nonlinear model of the full–wave bridge rectifier in AC circuit with RC load for non–rigid supply system. The mathematical model of the AC circuit for this load was worked out using dimensionless variables. The model of the circuit was created and analyzed with MATLAB/Simulink. Analysis of harmonic distortions of the currents and voltages in considered circuit was carried out. Indices of power quality are described. The current–voltage characteristics for different values of capacitive load are presented. The balances active and reactive powers in the circuit were performed.
PL
W pracy przedstawiono nieliniowy model prostownika mostkowego w obwodzie prądu przemiennego z indukcyjnością. Opracowano model matematyczny analizowanego obwodu oraz zaprezentowano metodykę formowania równań opisujących obwód z wykorzystaniem zmiennych bezwymiarowych. Na podstawie modelu matematycznego utworzono schemat operacyjny w programie Simulink i poddano go analizie. Przeprowadzono analizę zniekształceń harmonicznych przebiegów prądów oraz napięć rozważanego obwodu. Wyznaczono bilanse mocy czynnej oraz biernej w rozważanym obwodzie.
EN
The paper deals with the nonlinear model of a full-wave bridge rectifier in AC circuit with inductance. The mathematical model of the analyzed circuit was worked out. Methodology of circuit equations forming with use of the dimensionless variables is presented. On the basis of the mathematical model the operational diagram in Simulink was created. Analysis of harmonic distortion of the currents and voltages in considered circuit was carried out. The balances active and reactive powers in the circuit were performed.
|
|
tom Nr 62
67--70
EN
A two phase approach to obtain feasibility of the Security Constrained Unit Commitment schedules is analysed. In the first planning phase a computationally tractable variant of the security constrained UC problem is considered with a simplified representation of the network flows. Three computationally tractable variants of the UC problem formulations are investigated: (i) UC_NN model without network flow constraints, (ii) UC_NC model with network constraints reflected by enforcing nodal constraints at the bus level, and (iii) UC_DC model by enforcing network constraints on active power flows. These models are tested and compared with respect to efficiency, computational burden and complexity of the corrective actions performed by TSO in the operational phase to meet security and technical requirements of the system.
PL
W pracy jest analizowane podejście dwufazowe do problemu doboru jednostek i ekonomicznego rozdziału obciążeń w systemie elektroenergetycznym. W pierwszej fazie planistycznej jest rozważany uproszczony wariant problemu doboru jednostek i ekonomicznego rozdziału obciążeń z uproszczonym modelem ograniczeń sieciowych rozpływu mocy. Badane są trzy realistyczne obliczeniowo warianty modelu doboru jednostek i ekonomicznego rozdziału obciążeń: (i) model UC_NN bez ograniczeń sieciowych, (ii) restrykcyjny model UC_NC z ograniczeniami sieciowymi w postaci ograniczeń przepływu na poziomie szyn i łączy, and (iii) model UC_DC uwzględniający model rozpływu mocy czynnej w sieci. Modele te są testowane symulacyjnie i porównywane pod względem obliczeniowym, efektywnościowym oraz złożoności i jakości akcji dostosowawczych Operatora Sieci Przesyłowej w drugiej fazie operacyjnych działań pozwalających na uzyskanie stanów sieci spełniających wymagania bezpieczeństwa i ograniczenia techniczne.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.