EN
Synchronization of operation of an artificial chamber supporting the sick heart of a patient has a crucial meaning for the effectiveness of support. To make the synchronized operation possible, the information on patient's heart activity should be fed to a controller of the supporting chamber. To this end, the QRS complex detector operating on ECG signal is necessary. The signal must be acquired from a patient's heart. Appropriate signal quality at long-term support may be assured only in a case the signal is acquired with epicardial electrodes. In the paper, the concept of hardware construction of a QRS complex detector has been presented, based on a field programmable analog array FPAA. The results of verification of the developed detector include the correct operation while using the epicardial signals recorded from patients which undergone the cardiosurgical operations.
2
Content available remote Development of implantable assist pump and its peripheral devices
100%
EN
Two national project for development of an artificial heart system are being undertaken in Japan, and Hokkaido Tokai University has taken part in both national projects in order to develop peripheral devices of an implantable VAD (ventricular assist device) system. Each of the peripheral devices incIudes a transcutaneous energy transmission system, an internal battery system, and a transcutaneous information transmission system. Maximum energy transmission efficiency of the transcutaneous energy transmission system is over 85% (DC to DC) at an energy transmission ratio of 25 W. The internal battery system mainly consists of three lithium ion batteries, a charge circuit, and a power interface (case size of 11Ox80x30 mm). The internal battery system can drive a VAD for over 2 hours with maximum battery case surface temperature of 43°C. The information transmission system (diameter of 52 mm and thickness of 12 mm) mainly consists of an ASK modulator and an ASK demodulator employing carrier frequencies of 4 MHz and 10 MHz. It can transmit data electromagnetically between inside and outside of the body bi-directionally at a data transmission ratio of 56 kbps. Long-term animal experiments showed that each peripheral device has adequate performance to support the operation of implantable VAD.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.