Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 9

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  TEG
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
To analyze the predictive effect of thrombelastogram (TEG) in the changes of coagulation functions of patients with traumatic brain hemorrhage, as well as to provide a practice basis for clinical guidance. 54 cases were observed from Aug. 2013–Oct. 2014. All patients received a TEG test 1d, 3d and 7d after traumatic injury. According to the statistical analysis, the comparison among the aforementioned coagulation function parameters in each group of patients, K, α and Ma all had significant differences. In the comparison between different time points in the same group, there was still a significant difference. Compared to the patients, the changes of R and K reached the lowest at 1d and the highest at 3d, but there was no significant difference between two groups at 7d. The changes of α and Ma reached its highest at 1d and the lowest at 3d after traumatic injury, but there was no significant difference at 7d. There was some difference in changes of coagulation functions between all groups. The former was more serious and the changes of coagulation functions had certain regularity, i.e., after traumatic injury, 1d showed a hypercoagulable state; 3d showed a hypocoagulable state; the coagulation functions of 7d returned to normal.
2
Content available remote Generatory termoelektryczne - zasada działania, budowa, zastosowania
89%
PL
Zmniejszenie emisji gazów cieplarnianych jest jednym z głównych wyzwań stojących przed ludzkością w nadchodzących latach. Dlatego celem dla naukowców i przemysłu jest poszukiwanie alternatywnych źródeł energii oraz zmniejszenia zużycia energii przez zwiększenie wydajności produkcji, dystrybucji i końcowego wykorzystania z uwzględnieniem procesów odzyskiwania energii. Technologia termoelektryczna (TE) jest uważana za alternatywną i przyjazną w odniesieniu do środowiska technologię pozyskiwania i odzyskiwania ciepła. Generatory termoelektryczne (TEG) wykorzystują efekt Seebecka do bezpośredniej konwersji ciepła w energię elektryczną. Artykuł przybliża czytelnikowi zasadę działania TEG, stosowane materiały termoelektryczne oraz możliwe zastosowania. Tym samym zwraca uwagę, na wciąż niewykorzystywany w pełni potencjał generatorów termoelektrycznych i zauważa, że dalsze prace nad rozwojem tej technologii są konieczne.
EN
Reducing greenhouse gas emissions is one of the major challenge facing humanity in the coming years. Therefore, the goal for researchers and industry is to seek alternative sources of energy and to reduce energy consumption by increasing the efficiency of production, distribution and end-use, taking into account energy recovery processes. Thermoelectric (TE) technology is considered as an alternative and environmentally friendly technology for heat harvesting and recovery. Thermoelectric generators (TEG) use the Seebeck effect to directly convert thermal energy into electrical energy. This article introduces the reader to the principle of TEG, the thermoelectric materials used and possible applications. It also draws attention to the still not fully exploited potential of thermoelectric generators and notes that further development of this technology necessary.
PL
W niniejszej pracy przedstawiono badania temperatury spalin silnika spalinowego z zapłonem iskrowym. Termopary umieszczono przy bloku silnika oraz za. Badania wykonano dla wzrastających prędkości obrotowych od 750 obr/min do 3750 obr/min na biegu jałowym silnika spalinowego. Wyniki badań odniesiono do układów kogeneracyjnych z silnikiem Stirlinga oraz ogniwami termoelektrycznymi TEG. Wskazano możliwości zastosowania układów kogeneracyjnych z silnikiem Stirlinga oraz termogeneratorów TEG w celu zwiększenia sprawności silnika spalinowego wykorzystując odpadowe ciepło gazów spalinowych z układu wylotowego. Przedstawiono także wartości mocy elektrycznej kogenerowanej przez silnik Stirlinga przy temperaturze T > 500°C przy ciśnieniu 7 bar dla azotu. Zaprezentowano także wartości osiąganych mocy dla termogeneratorów elektrycznych umieszczonych w układzie wydechowym silnika ZI.
EN
The paper presents research ICE exhaust temperature. Thermocouples were provided at the engine block and exhaust manifold. Research performed for increasing speed of 750 rpm to 3750 rpm during idling ICE. The results are referenced to cogeneration systems with Stirling engine and TEG (thermoelectric generator). The paper presents the possibility of the use of cogeneration systems with a Stirling engine and TEG in order to increase the efficiency of internal combustion engine by using the waste heat of the exhaust gases from the exhaust system. The article presents the values of electric power cogenerated from Stirling engine for temperature heat source higher than 500°C at the pressure of 7 bar. The results was showed for Nitrogen which was working gas. Also presented electric power for TEG which was placed in the exhaust system.
EN
Thermoelectric generators using the Seebeck effect to generate electricity are increasingly used in various areas of human activity, especially in cases where a cheap high-temperature heat source is available. Despite many advantages, TEG generators have one major disadvantage: very low efficiency of heat conversion into electrical power which strongly depends on the applied load resistance. There is a maximum of generated power between the short and the open circuit in which it is zero. That is why optimization of TEG modules is particularly important. In this paper a method of maximization of generated power in a single TEG module is presented for two cases. The first case concerns a problem with fixed heat flux flow into the hot side of the module whereas the second one concerns a problem with fixed heat transfer parameters in hot heat exchanger i.e. supply gas temperature and heat transfer coefficient. A number of optimization results performed for various values of these parameters are presented and discussed.
PL
Termogeneratory TEG produkują energię elektryczną bezpośrednio z energii cieplnej. Zastosowanie TEG w systemie cieplnym umożliwia lokalne generowanie prądu stałego do zasilania urządzeń pomocniczych w źródłach ciepła. Podstawą doboru i wymiarowania zespołów TEG są ich charakterystyki termoelektryczne oraz dostępna w systemie cieplnym różnica temperatur.
EN
The TEG thermogenerators produce the electricity directly from the heat. The DC from TEG is used for the heat source equipment supply. The TEG design requires knowledge of the characteristics and the available temperature difference.
EN
The water content of glycol is important from the perspective of the dehumidification quality of natural gas, as the greater is it’s content, the more adversely it will affect further absorption of glycol during the dehumidification process. In order to restore its original properties, sorption glycol undergoes regeneration that is the process which consists of thermal evaporation of water contained therein. The separation of these components is made possible by the evaporation of water at a lower temperature, compared to glycols. In the industrial practice of dehumidifying natural gas using the absorption method, four kinds of glycol can be used. Their characteristics are presented in the report, discussing the current methods of regeneration, as well as presenting results from the laboratory tests which consisted of water content measurements taken after evaporation of water from the glycol solutions. These results were summarized and compared. To determine the content of water, the Karl Fischer titration method was used.
EN
This work describes new method to determine parameters of Peltier module. Classical method requires module to be disassembled, rendering it useless after the experiment. Described new method does not require interference in structure of the module allowing it to be used after experiment. This is helpful in designing of new modules, where there is few samples to test.
PL
Praca opisuje nową metodę wyznaczania parametrów modułów Peltiera. Metody klasyczne wymagają rozmontowania modułu, co powoduje jego zniszczenie. Prezentowana metoda zapewnia precyzyjny pomiar parametrów modułu Peltiera bez konieczności ingerencji w jego fizyczną strukturę. Jest ona szczególnie pomocna przy wytwarzaniu i testowaniu modułów prototypowych.
8
Content available remote Stabilising feedback in Max-Plus linear models of discrete processes
63%
EN
This article relates to a synthesising output feedback that is used to control a network of discrete events. The feedback stabilises the system without reducing its initial throughput and its synthesis is mainly based on the theory of residues and the Kleene operator. This article suggests some theoretical results and mathematical foundations of max-plus algebra theory, and in particularly, discusses various other aspects of controlling discrete processes and their modelling in the context of a linear max-plus system.
PL
Artykuł dotyczy syntezy sprzężenia zwrotnego w sterowaniu siecią zdarzeń dyskretnych. Sprzężenie zwrotne służy do stabilizacji systemu bez zmniejszenia jego początkowej przepustowości i jego synteza opiera się głównie na wynikach teorii residuów i operatora Kleene’a. W artykule zasygnalizowano pewne wyniki teoretyczne i wprowadzono matematyczne podstawy max-plus algebry. Omówiono także inne aspekty sterowania procesami dyskretnymi oraz ich modelowanie w kategoriach liniowego systemu max-plus.
9
Content available remote Modelowanie modułów termoelektrycznych w programie SPICE - przegląd
62%
PL
W artykule przedstawiono wyniki badań dwóch literaturowych modeli modułów termoelektrycznych dedykowanych dla programu SPICE. Przedstawiono topologię oraz równania opisujące te modele. Pokazano także wyniki weryfikacji ich dokładności poprzez porównanie wyników pomiarów i obliczeń wykonanych w programie SPICE. Niezbędne wartości parametrów wyznaczono w oparciu o dane producenta.
EN
In the paper results of research of two published in literature SPICE models of thermoelectric modules have been presented. Topology and equations describing these models, as well as results of experimental verification of their accuracy, based on comparison of results of SPICE calculation and measurements have been discussed. Required models parameters values have been calculated using manufacturer data.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.