Ten serwis zostanie wyłączony 2025-02-11.
Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  PV array
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The abundant use of solar energy in Indonesia has the potential to become electrical energy in a microgrid system. Currently the use of renewable energy sources (RESs) in Indonesia is increasing in line with the reduction of fossil fuels. This paper proposes a new microgrid DC configuration and designs a centralized control strategy to manage the power flow from renewable energy sources and the load side. The proposed design uses three PV arrays (300 Wp PV module) with a multi-battery storage system (MBSS), storage (200 Ah battery). Centralized control in the study used an outseal programmable logic controller (PLC). In this study, the load on the microgrid is twenty housing, so that the use of electrical energy for one day is 146.360 Wh. It is estimated that in one month it takes 4.390.800 Wh of electrical energy. The new DC microgrid configuration uses a hybrid configuration, namely the DC coupling and AC coupling configurations.The results of the study show that the DC microgrid hybrid configuration with centralized control is able to alternately regulate the energy flow from the PV array and MBSS. The proposed system has an efficiency of 98% higher than the previous DC microgrid control strategy and configuration models.
EN
This paper presents a novel, low-complexity method of simulating PV source characteristics suitable for real-time modeling and hardware implementation. The application of the suitable model of the PV source as well as the model of all the PV system components in a real-time hardware gives a safe, fast and low cost method of testing PV systems. The paper demonstrates the concept of the PV array model and the hardware implementation in FPGAs of the system which combines two PV arrays. The obtained results confirm that the proposed model is of low complexity and can be suitable for hardware in the loop (HIL) tests of the complex PV system control, with various arrays operating under different conditions.
EN
Distributed generation (DG) systems have been widely applied in power systems and will also be the dominant part of future power systems. This type of generation system has features that are distinctive among non-renewable huge capacity fossil and nuclear power generation systems. These types of distributed generation are comparatively very small and most оf them are constructed for the application оf nonconventional energy such as hydraulic power or wind power in the generation of electricity. And, whenever this type of DG system аre functioned in parallel together with main utility power systems, then particularly the power quality problem beсоme more significant with reverse power flow. Reliability, frequency deviation, harmonics, and voltage deviation of the power system are the main power quality problems. Also, a critical, and major problem of power quality is аn islanding protection. Tо resolve islanding problems, the detectors of islanding conditions аre used tо find аn islanded situation and allow the circuit breaker to trip. These circuit breakers are available in between the distributed generation and the power system. This Paper presents а nоvel concept оf the detection of islanding by the support of Slip Mоde Frequency Shift (SMFS) technique fоr the defense оf distributed generator fed systems from the Islanding conditions which has been tested and verified by the help of the proposed Simulink diagram on Matlab-2021a platform.
PL
Systemy generacji rozproszonej (DG) są szeroko stosowane w systemach elektroenergetycznych i będą również dominującą częścią przyszłych systemów elektroenergetycznych. Ten typ ma cechy charakterystyczne dla nieodnawialnych systemów wytwarzania energii z paliw kopalnych i jądrowych o dużej mocy. Różne rodzaje generacji rozproszonej są porównywalnie małej mocy i większość z nich jest konstruowana do wykorzystywania energii niekonwencjonalnej, takiej jak energia hydrauliczna lub energia wiatru do wytwarzania energii elektrycznej. I kiedy ten typ systemu DG działa równolegle z głównymi systemami zasilania, to szczególnie problemy z jakością zasilania stają się bardziej znaczące przy odwróconym przepływie mocy. Niezawodność, odchylenie częstotliwości, harmoniczne i odchylenie napięcia systemu elektroenergetycznego to główne problemy dotyczące jakości energii. Ponadto krytycznym i głównym problemem jakości energii jest ochrona wysp. Aby rozwiązać problemy związane z wyspą, detektory warunków wyspowych są wykorzystywane do wykrycia szczególnej sytuacji na wyspie i umożliwienia przerwania obwodu. Wyłączniki są dostępne pomiędzy generacją rozproszoną a systemem elektroenergetycznym. Niniejsza praca przedstawia nowatorską koncepcję wykrywania zjawisk wyspowych przy pomocy techniki przesunięcia trybu poślizgu częstotliwości (SMFS) do ochrony systemów zasilanych z generatorów rozproszonych przed warunkami wyspowymi. Pomysł został przetestowany i zweryfikowany za pomocą proponowanego diagramu Simulinka na platformie Matlab-2021a.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.