Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 14

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  EDA
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
2
Content available remote EDA tools for designing ΣΔ modulators working in the currentmode
84%
EN
The article presents original tools for automating designing sigma-delta modulators working in the current mode. The solution makes it possible to optimize any modulator structure, to verify the compliance of the project with technological rules and to automate designing the layout of the circuit. The tools are compatible with popular design environments for CMOS circuits and with languages for describing circuit architectures. The proposed solution offers the designer the freedom of defining parameters expected of the modulator. The final result of the design process is a modulator topography obtained in a fully automated way and ready for fabrication. The effectiveness of the tools is demonstrated with an example of a modulator based on a current-to-frequency converter. The result of the design process was an SNDR coefficient equal to 76dB and the Walden’s FoM equal to 616fj/step for 20kHz bandwidth.
PL
W artykule zaprezentowano autorskie narzędzia służące automatyzacji projektowania modulatorów sigma-delta pracujących w trybie prądowym. Przedstawione rozwiązanie umożliwia optymalizację dowolnej struktury modulatora, weryfikację zgodności projektu z regułami technologicznymi oraz automatyzację projektowania layoutu układu. Narzędzia zgodne są z popularnymi środowiskami projektowania układów CMOS oraz językami opisu architektury układów. Zaproponowane rozwiązanie oferuje projektantowi swobodę definiowania oczekiwanych parametrów modulatora, a finalnym rezultatem procesu projektowego jest w pełni automatycznie uzyskana topografia modulatora nadająca się do fabrykacji. Skuteczność narzędzi zademonstrownao na przykładzie modulatora bazującego na przetworniku prąd-częstotliwość. W wyniku procesu projektowego uzyskano współczynnik PSNR równy 76dB oraz Walden’s FoM równy 616fj/step dla pasma 20 kHz.
3
84%
PL
Przeprowadzony w niniejszej pracy eksperyment jest wstępną próbą oszacowania przydatności pomiaru aktywności elektrodermalnej (EDA) do oceny wpływu pola elektromagnetycznego (PEM) na organizm w badaniu o charakterze kazuistycznym.
EN
The experiment carried out in this paper is an initial attempt to estimate the usefulness of the measurement of electrodermal activity (EDA) for the assessment of the impact of electromagnetic field (PEM) on the body using a case study approach.
|
2019
|
tom R. 95, nr 12
70--74
PL
W artykule zaprezentowano metodę opracowaną do przetwarzania sygnałów EKG oraz EDA (tj. aktywności elektrodermalnej), które zarejestrowano podczas testów stosowanych w diagnostyce autonomicznego układu nerwowego. Do oceny aktywności układów współczulnego i przywspółczulnego przyjęto parametry opisujące zmienność mocy sygnału reprezentującego fluktuacje rytmu serca w charakterystycznych pasmach częstotliwości, które zostały wydzielone za pomocą analizy falkowej. Sygnał EDA wykorzystano do weryfikacji wyników.
EN
In this article, the method developed for processing of ECG and EDA (i.e. electrodermal activity) signals recorded during tests using in diagnostics of the autonomic nervous system (ANS) was presented. The parameters describing the power variability of the heart rate fluctuations in characteristic frequency bands extracted by a wavelet analysis were applied to assess the activity of the sympathetic and parasympathetic nervous systems. The EDA signal was used to verify the obtained results.
5
Content available remote Prototypowe dwuwymiarowe filtry żyratorowo-pojemnościowe
84%
PL
Niniejsze opracowanie przedstawia koncepcję zunifikowanego opisu struktury obwodu dla dwuwymiarowej filtracji. Wprowadzono sposób podziału obwodu o parametryzowanej strukturze oraz dużej elastyczności w zakresie wyrażania topologii, rzędu układu filtrującego oraz liczby zmiennych niezależnych, wyznaczającej wymiar struktury. Opisano sposób relizacji analizy symbolicznej tego typu struktur z uwzględnieniem możliwości jej zaimplementowania w formie oprogramowania komputerowego klasy CAD/EDA. Przedstawiono także koncepcję syntezy obwodu w oparciu o wyniki analizy symbolicznej, która stanowiłaby etap wyjściowy do zrealizowania projektowanego układu w postaci scalonej. Omówiony został również przegląd potencjalnych zastosowań takiej metodologii projektowania w kontekście realizacji układów klasy System on Chip (SoC). Na koniec przedstawiono możliwe uogólnienie podanej metodologii projektowania na układy wielowrotników wielowymiarowych.
EN
The following paper presents a method of unified description for circuits’ structure for two-dimensional filtration. The structure may be parameterized by altering the number of used operators giving making the description flexible and easy to use. VHDL-AMS language was proposed for expressing the structure. Additionally CAD/EDA class software was elaborated for perfoming symbolic analysis of the elaborated structures. The paper gives a brief overwiev of the software capabilites and limitations. This may be considered as the initial step for making circuit synthesis. This approach may be easily extended for analysis of multidimensional multiport circuits.
6
Content available remote Classification of pilots' mental states using a multimodal deep learning network
84%
EN
An automation system for detecting the pilot's diversified mental states is an extremely important and essential technology, as it could prevent catastrophic accidents caused by the deteriorated cognitive state of pilots. Various types of biosignals have been employed to develop the system, since they accompany neurophysiological changes corresponding to the mental state transitions. In this study, we aimed to investigate the feasibility of a robust detection system of the pilot's mental states (i.e., distraction, workload, fatigue, and normal) based on multimodal biosignals (i.e., electroencephalogram, electrocardiogram, respiration, and electrodermal activity) and a multimodal deep learning (MDL) network. To do this, first, we constructed an experimental environment using a flight simulator in order to induce the different mental states and to collect the biosignals. Second, we designed the MDL architecture – which consists of a convolutional neural network and long short-term memory models – to efficiently combine the information of the different biosignals. Our experimental results successfully show that utilizing multimodal biosignals with the proposed MDL could significantly enhance the detection accuracy of the pilot's mental states.
PL
W artykule opisano projekt układu elektronicznego przeznaczonego do badania reakcji GSR (ang. Galvanic Skin Response) z uwzględnieniem trudności związanych z charakterem pomiaru. Omówiono w nim biologiczny mechanizm powstawania reakcji skórno-galwanicznej, budowę zaprojektowanego urządzenia pomiarowego oraz metodykę badań przeprowadzonych w celu sprawdzenia użyteczności urządzenia.
EN
The article describes the project of GSR measurement system, taking into account all difficulties related to the type of the measurement. It discusses the biological mechanism of the skin-galvanic reaction, the construction of the designed device for measuring this reaction, and the methodology of tests carried out to check the usefulness of the device.
8
83%
EN
Risings costs of providing weapons and equipment for modern armies have led to countries’ increased interest in economic and defence cooperation. The paper presents the significance of this cooperation for the countries of the European Union. The author explains the essence of the economic and defence cooperation, ways of its implementation, and the benefits that can be gained from this cooperation. The paper focuses on the implementation of joint programs of acquiring modern weapons, in particular the programs in the area of research and development of modern military technologies. The presented analysis underlines a new quality of EU states’ cooperation, i.e. the making of joint development investments by EU states, which is managed by the European Defence Agency.
PL
Przedstawiono krótko analizę modyfikowania siluminu z zastosowaniem metody EDA. Warstwa wierzchnia była modyfikowana w procesie obróbki elektroerozyjnej za pomocą elektrody kompozytowej wykonanej ze spieku Fe-WC. Wykonano podstawowe badania metalograficzne oraz EDS naniesionej warstwy. Na tej podstawie określono skuteczność przenoszenie się składników stopowych z elektrody do materiału modyfikowanego.
EN
The article presents a brief analysis of the deposition layer using EDA. The surface layer was modified using electrodes Fe - WC on the machine electro-erosion. The layer was tested by metallographic methods and EDS. There were identified on the basis of which the transmission of alloying elements from the electrode to the weld overlay.
11
Content available remote Morphology of traces made by individual electric discharge in the EDM
67%
EN
The paper deals with a new method of investigating traces made by individual discharge using SEM and scanning profilometers. Surface microstructure is assessed using the SEM while dimensions and volumes of individual craters are determined basing on scanning profilometer SP. The influence of machining conditions on micro-structure of trace surface, crater and flash dimension and volume were investigated. It was concluded that discharge traces after the EDM (Electro-Discharge Machining) are typical of strong connection with machining parameters and they are highly repeatable whereas discharge traces generated on the cathode surface during the EDA (Electro Discharge Alloying) are much larger than those after the EDM and they are typical of much less uniform size and volume.
PL
W pracy przedstawiono charakterystykę śladów pojedynczych wyładowań generowanych podczas obróbki EDM i EDA. Prowadzono badania za pomocą mikroskopu skaningowego (SEM) i profilometru skaningowego. Powierzchnię śladów wyładowań obserwowano za pomocą mikroskopu SEM, natomiast rozmiary i objętość kraterów określono, stosując profilometr skaningowy. Ustalono wpływ parametrów obróbki na mikrogeometrię powierzchni, a także rozmiary oraz objętość kraterów i wypływek. Stwierdzono, że rozmiary śladów wyładowań po EDM są ściśle skorelowane z parametrami obróbki i charakteryzują się dużą powtarzalnością. Ślady wyładowań generowanych podczas stopowania elektroiskrowego (EDA) mają natomiast większe rozmiary w porównaniu z obróbką EDM. Charakteryzuje je również duża przypadkowość.
EN
The study aimed to examine the influence of providing information about reacting to the heard musical stimuli while treadmill walking on physiological signals of participants. The study group consisted of 30 adults: group 1 was not informed how to react, group 2 received an instruction to adjust the frequency of steps to the music. The gait was carried out on a Zebris FDM-S treadmill for various sound stimuli using the Empatica E4 band to acquire electrodermal activity and heart rate. Information about moving to the stimuli did not change how the subjects responded physiologically during the test.
PL
Celem badania było sprawdzenie, czy informacje o sposobie reagowania na słyszane bodźce muzyczne podczas chodzenia na bieżni istotnie wpływają na sygnały fizjologiczne uczestników. W badaniu uczestniczyło 30 dorosłych: grupa 1 nie została poinformowana o tym, jak reagować na słyszane dźwięki, grupa 2 otrzymała polecenie dostosowania częstotliwości kroków do muzyki. Chód rejestrowano na bieżni Zebris FDM-S, a do akwizycji sygnałów fizjologicznych wykorzystano opaskę Empatica E4. Informacje o tym, jak reagować na bodźce nie zmieniały sygnałów fizjologicznych u badanych.
13
67%
EN
With the improvement of the gate complexity, the verification overhead becomes more decisive for VLSI design cost In order to reduce the simulation time, a adaptive partition based parallel method of VLSI logic simulation with GPGPU is addressed in this paper. The numerous arithmetic blocks of GPGPU is utilized simultaneously for disparate circuit macros. The partition strategy we proposed shows a sufficient flexibility to balance the different work load in parallel threads and fit the feature of GPU architecture. To explore the parallelism and locality of logic simulation further, the circuit macro is organized as stream data. The data dependency between the input and output nets in one individual logical path is handled with the shared memory of GPGPU. As for different logical paths, the dependency is processed by threads synchronization. To illustrate the performance, a serial experiments is implemented in Intel CoreDuo workstation with Nvidia GTX465 GPU board. Four typical digital circuits (LDPC, DES3, OpenRISC 1200 and OpenSPARCPARC T1) are considered as the benchmark. The result of experiments demonstrate a significant speed-up is achieved by using GPGPU parallel method, comparing with the CPU serial logic simulation. In maximal case (OpenS T1), the GPGPU parallel acceleration computes 21 times faster than serial program.
EN
In this article, we present a comprehensive measurement system to determine the level of user emotional arousal by the analysis of electrodermal activity (EDA). A number of EDA measurements were collected, while emotions were elicited using specially selected movie sequences. Data collected from 16 participants of the experiment, in conjunction with those from personal questionnaires, were used to determine a large number of 20 features of the EDA, to assess the emotional state of a user. Feature selection was performed using signal processing and analysis methods, while considering user declarations. The suitability of the designed system for detecting the level of emotional arousal was fully confirmed, throughout the number of experiments. The average classification accuracy for two classes of the least and the most stimulating movies varies within the range of 61‒72%.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.