The objective of this work is to present an energy analysis of different absorption refrigerating systems operating with diverse refrigerants. Also is applied the method of experimental design to optimize configurations proposed by the absorption pairs used and the operating conditions. Both acceptable coefficient of performance and low operating generator temperature are scrutinised. Therefore, a computer program is developed. An investigation of the thermodynamic properties is presented. Results show the coefficient of performance evolution versus respectively the evaporator temperature, temperature of condensation and generator temperature. A particular interest is devoted to the intermediate pressure effect on the performance of different systems. In order to better converge in the selection of the configuration and the refrigerant, which can ensure a high coefficient of performance associated to relatively low operating generator temperature the plan of experiments has been developed, taking in account all parameters influencing the system performance and the function of operating temperature. Results show that the refrigerating machine containing a compressor between the evaporator and the absorber has a coefficient of performance quite acceptable and that it can work at low generator temperature for about 60°C and using the NH3/LiNO3 as refrigerant.
2
Content available remote Wspólny obraz sytuacji operacyjnej a środowisko sieciocentryczne
100%
EN
The article presents the interrelations that appear while creating a common operational picture (COP) while conducting operations in network centric environment. COP means integrating the possibilities of reception, correlation and imagery of common operational tactical picture which includes the application of operations planning, overlapping and generating layers at the theatre of operations and projection of data including selected elements basing on data filtration and aggregation. This facilitates common planning and allows all participants to reach the situational awareness which should be shared by more than one decision-making centre.
EN
Paper deals with theoretical analysis of possible efficiency increase of compression refrigeration cycles by means of application of a two-phase ejector. Application of the two phase ejector in subcritical refrigeration system as a booster compressor is discussed in the paper. Results of exergy analysis of the system operating with various working fluids for various operating conditions have been shown. Analysis showed possible exergy efficiency increase of refrigeration compression cycle.
EN
The description of original technical decision of using heat pump for heating part of administrating building is described. The hydraulic connection scheme has been developed and selection of heat devices was made for it. The energy efficiency for using heat pump in heating season is analyzed. Based on the obtained experimental data, the coefficient of performance of the heat pump was calculated for the above mode of operation of the heat supply system. With such indicators, a significant saving of thermal energy is achieved in comparison with the use of a centralized heat supply system.
EN
CO[2] is a potential substitute for synthesized refrigerants with favourable environmental properties. Improvment of the coefficient of performance (COP) of carbon dioxide refrigeration, heat pumping and heating - cooling systems is a necessary condition. Energetic and thermodynamic analysis as well as optimisation studies of an isentropic and nonisentropic compression process are presented in the article. The results show that COP of the transcritical carbon dioxide cycle varies with the heat rejection pressure. Maximum COP occurs at an optimal heat rejection pressure, which depends mainly on outlet temperature of the gas cooler, evaporation temperature and performance of compressor. Correlations of the optimal heat rejection pressure in terms of appropriate parameters were obtained for specific conditions based on simulations of the cycle. The COP changes indicate that such system is more suitable for high heating end temperatures and modest cold end temperatures. Expressions for optimum cycle parameters have been developed. These correlations offer useful guidelines for optimal system design and for selection of appropriate operating conditions.
EN
Solid-state thermoelectric elements, such as thermoelectric (TE) modules, can be used as cooling devices. Small-sized TE modules, characterized by: lack of moving parts, no required refrigerants application as well as variable possible installation and operation positions, allow, in several specified cases, achieving the advantage in cooling process over the conventional refrigeration devices. This paper presents the results of the preliminary numerical determination of energetic efficiency of thermoelectric cooling system, applied for cooling a small-scale experimental room. The heat exchangers used in the cooling system consisted of heat sinks and radiators installed on the both sides of the TE module. The numerical assessment included in this paper, based on a 3D model reflecting the experimental room and thermoelectric cooling system, allowed determining the relation between TE module power supply characteristics and cooling effects, as well as time-related temperature distribution inside the modeled experimental room. The commercial modeling software FLUENT, ANSYS 12.0 by ANSYS Inc. was applied in numerical calculations. The results of the performed laboratory studies were used as a basis for model development, required input data, initial and boundary conditions. The results of laboratory tests showed the influence of amperage of power supply on the efficiency of cooling characteristics, as well as distribution of air temperature inside the experimental room. Calibration and validation of the developed model was also based on the results of laboratory experiment. The obtained results of numerical calculations showed the influence of amperage of power supply on efficiency of cooling characteristics as well as distribution of air temperature inside the experimental room.
PL
Procesy transformacji gospodarczej, społecznej i kulturowej, związane z wdrażaniem reguł gospodarki rynkowej, dokonujące się na obszarze Polski Południowo-Wschodniej charakteryzują się poważnym zróżnicowaniem przestrzennym, a także odmiennością w odniesieniu do innych części kraju. Generalnie związane są one z osłabianiem tempa industrialnego rozwoju i zwiększaniem się roli sektorów usługowych. Wynika to z charakteru struktur społeczno-gospodarczych wykształconych we wcześniejszych okresach. Z. Zioło (1999) przyjmuje, iż na terenie Polski Południowo-Wschodniej procesy zmian struktury bazy ekonomicznej najwcześniej, bo już w 1978 r. zaznaczyły się na terenie byłego województwa krakowskiego, w następnym 10-leciu stopniowo obejmowały kolejne województwa.
EN
In order to further increase the energy efficiency of the experimental building, field experiments were conducted to maintain the proper thermal regime of its premises when using a heat pump heating system. The paper presents the results of experimental studies of the operating parameters of the heat pump heat supply system of an energy-efficient building of the Institute of Engineering Thermophysics of the National Academy of Sciences of Ukraine. The given analysis of the energy efficiency of the operation of the "soil-water" type heat pump in the nominal mode with the maximum load showed a high value of the energy conversion coefficient.
PL
A three-year plan (1933-1936) for expanding aviation developed at the Headquarters marked a turning point in productin the aeronautical engines. The imlementation of the process of building new craft (reconnaissance, fighter and bombing plabes) forced a decision to start a research on the propotypes of Polish engines. Due to the Śkoda concern's lack of enthusiasm for further cooperation and political implications in Polish-Cczechoslovakian relations, the cooperative activity edned. At that time the enigne manufacturers were incorporated in the PZL (State Aviation Works). Despite initial difficlties regarding a decline in production caused mainly by modernization and reorganization proceedings, the standards of the Śkoda Polish Works were quikly reached and exceeded considerably. The licensed production of England enginiers made by the Bristol Aircraft Ltd (Jupiter, Mercury, Pegasus, Hercules, Acquilla, Perseus) was implemented, and at the same time the researches on the prototypes of  Polish engines (Mors, Foka, waran, Legwan) were conducted. Smaller manufactures such as: the Autorrations carried by the army led to initating bulemont Mechanical Workship (Autstro-Daimler, Hispano-Suiza, Renaut Lorraine-Dietrich), the Stefan Twardowski Mechanical Works (Le Rhone, Hispano-Suiza, TK 70), the State Engineering Works (Walter "Junior" and "Major"), the Avia Precision Mechanics Manufacturer (La Rhone, WZ 7, Bristol-Jupiter, Wright "Whirlwind", Gnome-Rhone "Mars" 14 and "Delfin", Avia P4) cooperated with yhe army administration in the range of areo engines of low and medium ratio of strengh. Dissatisfaction with the mobilization preparations carred by the army led to initiating building works within the COP (Central Industrial District). The dcision concerning expansion of the aviation industry was taken during the meeting of the KSUS an 13 October, 1936. Before the WWII broke out, the production had in the State Aviation Works, Aircraft Factory Nr 2 in Mielec and the Aero Engines factory Nr 2 in Rzeszów. As regards the productions of aero engines, the following factories cooperated: Erazm Mieszczański and tadeusz Jaroszyński Warsaw Base Metal Foundry, Władysław Leszczyński High Grade Alloy Foundries, and the COP Ancillary Industry. The level of productions, to reach a number of 136 at the  end of the second half-year. This discordance actually showed that in order to meet the growing demand, imports of a number of ready-made units would be a must.
PL
W pracy przedstawiono optymalizację doboru zbiornika buforowego dla pompy ciepła włączonej w układ grzejny obiektu szklarniowego. Badania oraz optymalizację przeprowadzono podczas pracy pompy współpracującej z trzema wybranymi pojemnościami zbiornika buforowego. Ustalenie wielkości zbiornika buforowego w systemie grunt – woda wymaga uwzględnienia wielu czynników zarówno od strony układu grzewczego szklarni, układu pobierania ciepła z gruntu, jak również samej pompy ciepła. Rozważano przypadek graniczny – zapotrzebowanie na ciepło, które jeszcze może dostarczyć pompa ciepła w systemie monowalentnym. Przyjęto, że nadrzędnym kryterium powinna być maksymalizacja efektywności COP, ale z równoczesnym zapewnieniem zdolności do generowania przez układ ustalonych, granicznych ilości ciepła. Uwzględniono różnice taryf cen energii elektrycznej, także sformułowano inne ograniczenia związane z doborem zbiornika buforowego. Wielkość zbiornika jest między innymi konsekwencją założeń dotyczących strategii eksploatacji dolnego źródła ciepła. Zagadnienie to w pracy rozszerzono. Stwierdzono, że wielkość zbiornika buforowego zależy od lokalnych własności źródła dolnego, które w skali kilku sezonów grzewczych nie ma stacjonarnego charakteru. Stąd zbiornik buforowy powinien posiadać możliwość wydzielania mniejszych objętości stosowanych w zależności od ilości energii pobieranej z jednego metra bieżącego dolnego źródła ciepła. Następnie korzystając z symulacji komputerowych, wykazano, że istnieją uzasadnione ograniczenia dla stosowania zbiorników zbyt małych lub zbyt dużych. W wytypowanym przedziale należy poszukiwać optymalnego zbiornika na drodze doświadczalnej, z uwagi na udział zbyt wielu zmiennych zmniejszających precyzję drogi obliczeniowej.
EN
The paper presents optimisation of selection of the buffer bin for the heat pump connected to the heating system of a greenhouse. The research and optimisation was carried out during operation of the pump, which cooperated with three selected volumes of the buffer bin. Determination of the buffer bin size in the ground-water system requires including many factors both coming from the heating system of a greenhouse, the heat collection from the ground system as well as the heat pump itself. A boundary case of the heat demand, which still may be delivered by the heat pump in the monovalent system was considered. It was assumed that maximization of COP effectiveness should be a superior criterion but with simultaneous ensuring the ability to generate by the system determined, borderline amount of heat. Differences of price lists of electric energy were included; moreover, other limitations related to selection of the buffer bin were formulated. A bin size, inter alia, results from assumptions concerning the strategy of exploitation of a lower heat source. This issue was extended in the paper. It was found that the buffer bin size depends on the local properties of the lower source, which in the few heating seasons scale has no stationary character. Therefore, a buffer bin should have a possibility of separating smaller applied volumes depending on the amount of the collected energy from one current meter of the lower heat source. Then, using a computer simulation, it was proved that there are justified limitations for using too small or too big bins. In the selected range one should search for an optimal bin by means of an experiment, due to participation of too big number of variables, which decrease the cultivation precision.
PL
Artykuł pokazuje dorobek architektoniczny powstały w ramach realizacji Centralnego Okręgu Przemysłowego w kontekście konieczności jego zachowania i ochrony. Prezentowane są wybrane zagadnienia i problemy związane z aktualnym stanem technicznym obiektów budowlanych, zarówno przemysłowych jak i mieszkalnych. Analizie poddany jest również wpływ współczesnych doktryn konserwatorskich na możliwości zachowania dzieł architektury COP-u przy specyficznych warunkach własnościowych, niewielkiej świadomości użytkowników i właścicieli oraz dużym niedoborze źródeł historycznych i planistycznych.
EN
The article presents the architectural heritage created as a part of the Central Industrial District in the context of the need for its preservation and protection. Presented are selected topics and problems associated with the current technical condition of both industrial and residential buildings. The analysis contain also the impact of modern conservation doctrines and their ability to preserve works of COP’s architecture with the specific conditions of ownership, poor awareness of users and owners, and a large shortage of historical planning sources.
PL
Umiejętność wszechstronnej i obiektywnej oceny układu równowagi jest niezbędna do oceny postępów terapii i umiejętności równoważnych w sporcie. Niestety, wciąż bardzo niewiele osób zajmujących się fizjoterapią, leczeniem czy treningiem sportowym posiada wiedzę wystarczającą do przeprowadzenia badań równowagi i ich prawidłowej interpretacji. Celem pracy jest przedstawienie podstawowych pojęć, koncepcji i metod niezbędnych do prowadzenia tego typu badań. Szczególną uwagę zwrócono na terminologię, ogólną interpretację sygnałów mierzonych za pomocą platformy sił podczas swobodnego stania oraz na przebieg procedur doświadczalnych.
EN
The ability to assess the postural performance and stability in a comprehensive and objective way is a prerequisite for the evaluation of progress in therapy or to judge about the significance of postural control in sports. However, neither therapists, clinicians, nor athletic trainers have sufficient skills to perform such assessment. The purpose of this paper is to present the basic notions and methods needed to perform such studies. Attention is focused on terminology, the general interpretation of time-series recorded during quiet stance on force plates and on the experimental procedures.
PL
W artykule przedstawiono wyniki badań parametrów termodynamicznych w celu zwiększenia efektywności energetycznej sprężarkowej powietrznej pompy ciepła o mocy 14 kW. Publikacja zawiera: wprowadzenie, opis rynku pomp ciepła w Polsce oraz zakres wykonanych badań własnych oraz szczegółowo zawiera opis opracowanego modelu matematycznego z wykorzystaniem teorii i planowania eksperymentu.
EN
The article presents the results of research on thermodynamic parameters in order to increase the energy efficiency of a 14 kW air compressor heat pump. The publication includes: an introduction, a description of the heat pump market in Poland and the scope of own research, and includes a detailed description of the mathematical model developed using the theory and experiment planning.
14
Content available remote Zastosowanie pompy ciepła w energooszczędnym budynku z aktywnymi stropami
84%
PL
W 2009 roku w Katowicach na terenie parku przemysłowego Euro-Centrum otwarto innowacyjny biurowy budynek energooszczędny. Obiekt ten cechuje się zastosowaniem wielu nowych rozwiązań, dzięki którym znacznie ograniczono jego potrzeby energetyczne w stosunku do obiektów tradycyjnych. W artykule zaprezentowano wybrane aspekty praktyczne funkcjonowania systemu ogrzewania i chłodzenia obiektu, wykorzystującego technologię stropów aktywnych współpracujących z pompami ciepła. Przedstawiono także wybrane przebiegi zmienności zapotrzebowania pomp ciepła na energię elektryczną oraz wyznaczono ich eksploatacyjny współczynnik COP.
EN
In 2009, in the Industrial Park Euro-Centrum Katowice, there was opened an innovative low-energy office building. It is characterized by the application of a wide range of new solutions that significantly reduced its energy requirements compared to traditional buildings. The article presents some aspects of the practical operation of the heating and cooling system of the building using the technology of the thermally activated slabs with heat pumps. There were also presented selected waveforms of the electricity demand of heat pump and its COP factor was calculated.
15
Content available The influence of sounds on posture control
84%
EN
Purpose: It is still not clear which parameters of sound are the most significant for body reactions and whether the way of sound reception plays a role in body control. The purpose of this study was to determine the influence of frequency, spectrum and loudness of sounds on posture control in healthy women and men. Methods: The study subjects were 29 young adults who were submitted to a 60-second standing test in the bipedal stance on the force platform (AMTI). During the tests, 3 sinusoidal sounds with various timing and 2 musical sounds (guitar and piano) of the frequency 225 Hz, 1000 Hz and 4000 Hz were applied through headphones. The centre of pressure (COP) amplitude was registered. The sway area and COP mean velocity were computed. Results: It was found that high frequency sounds contributed to a significant decrease of sway area values. No significant influence of low frequency sounds on posture control was observed. The influence of the sound spectrum (timbre) on posture control is limited; only the crescendo spectrum improves the body stability in the bipedal stance and not the music spectrum as guitar and piano. The loudness of sound, although extremely high, is not the cause of postural control changing in relation to lower loudness. No effect of gender was found in terms of body stability under different sound conditions. Conclusion. Based on the results, it can be argued that, in general, in a bipedal stance in terms of stability high sound frequency improves posture control, whereas sound spectrum and intensity show a limited impact.
PL
Artykuł przedstawia historię budowy osiedli robotniczych, powstałych w latach funkcjonowania Centralnego Okręgu Przemysłowego 1936-1939. Jest próbą nakreślenia cech charakterystycznych procesu inwestycyjnego, od momentu powstania koncepcji, poprzez finansowanie, a skończywszy na ukształtowaniu formalnym i funkcjonalnym. Autor akcentuje, w sposób szczególny, założenia architektoniczne i urbanistyczne nawiązujące do ideii modernizmu i funkcjonalizmu dwudziestolecia międzywojennego.
EN
The article presents the history of workers' housing that were errected during the years of functionality of the Central Industrial District from 1936 to 1939. It attempts to outline the characteristics of the investment process from its conception, through financing, through to formal and functional solutions. The author emphasizes, in a special way, architectural and urban assumptions referring to the functionalism and modernism conceptions during the interwar period.
18
Content available Portable heat pump testing device
84%
EN
The aim of this paper is to present the design and working principle of a portable testing device for heat pumps in the energy recirculation system. The presented test stand can be used for any refrigerating/reverse flow cycle device to calculate the device energy balance. The equipment is made of two portable containers of the capacity of 250 liters to simulate the air heat source and ground heat source with a system of temperature stabilization, compressor heat pump of the coefficient of performance (COP) of = 4.3, a failsafe system and a control and measurement system.
PL
Artykuł obrazuje najważniejsze przedsięwzięcia z zakresu użyteczności publicznej powstałe w Starachowicach w latach Centralnego Okręgu Przemysłowego (1936-1939). Autor stara się pokazać powiązanie tych inwestycji ze sobą, ukazać ich kontekst i rolę jaką odgrywały. Na tle ponownego zainteresowania modernizmem międzywojennym obiekty te, często zaniedbane i zdewastowane, powracają do łask, a dla mniejszych ośrodków takich jak Starachowice, są ważnym punktem odniesienia w historii miasta.
EN
This paper presents the most important public architectural investments which were built in the years of Central Industrial Area (1936-1939) in Starachowice. Author shows connection between them, point out their context and their role during their prime time. On the background of interest in between-war modernism and functionalism those buildings - very often ruined and devastated - are the subject of admiration and for the small cities like Starachowice can be important as points of historical references.
PL
W artykule porównano wartości sezonowego współczynnika efektywności grzewczej wybranych pomp ciepła, określone na podstawie normy PN-EN 14825, wytycznych VDI 4650 oraz danych szacunkowych zawartych w rozporządzeniu w sprawie metodologii wyznaczania charakterystyki energetycznej budynku. W ramach przeprowadzonej analizy wskazano na różnice w uzyskanych wynikach oraz przyczyny ich występowania. Wykorzystane metody różnią się od siebie zarówno sposobem, jak i zakresem uwzględnienia poszczególnych czynników mających wpływ na wartość sCOP. Pomimo że żadna z porównywanych metod nie uwzględnia wszystkich czynników związanych z eksploatacją pomp ciepła, podkreślono, że pozwalają one na istotną poprawę jakości analiz energetycznych w stosunku do wykorzystania danych szacunkowych.
EN
The paper presents comparison of values of seasonal coefficient of performance of selected heat pumps, determined on the basis of PN-EN 14825, VDI 4650 guidelines and estimated data provided in the regulation on the methodology for determining the energy performance of a building. In the analysis, the differences in the obtained results an well as the causes for their occurrence were indicated. The methods used differ in both the way and scope of taking into account various factors affecting the sCOP value. Although none of the compared methods takes into account all of the factors related to the operation of heat pumps, it was emphasized that they allow a significant improvement in the quality of energy analyses compared to the use of estimated data.