Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  APF
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper presents a comparison of three control strategies that were applied in the simulation model of a four-leg Shunt Active Power Filter based on two-level voltage-source converter. The research considered two classical methods and one proposed as an alternative. In the first an instantaneous power theory is used for the references calculation and hysteresis controllers for gates signals generation. The second employs PI controllers and PWM modulation. The third method is Model Predictive Control with a finite control-states set number (FS-MPC). The comparison is based on simulations performed in Matlab-simulink.
PL
W artykule przedstawiono porównanie trzech metod sterowania dwupoziomowym czterogałęziowym aktywnym filtrem mocy. Dwie z metod stanowią rozwiązania klasyczne, natomiast trzecia metoda proponowana jest, jako rozwiązaniem alternatywne. W pierwszej metodzie zastosowano teorię mocy chwilowych oraz regulatory histerezowe; druga metoda bazuje na regulatorach PI oraz modulacji PWM. Trzecia metoda to sterowanie predykcyjne wykorzystujące model o ograniczonej ilości stanów (FS-MPC). Porównanie dokonane zostało na podstawie symulacji w programie Matlab-Simulink.
3
Content available remote Spojrzenie na zarządzanie projektami informatycznymi
84%
PL
W artykule scharakteryzowano zarządzanie projektami wg SCRUM, APF, xPM. Przedstawiono zarządzanie projektami informatycznymi polegające na prowadzeniu projektu wzdłuż jego optymalnego kursu, który rozwija się w trakcie trwania projektu, co pozwala użytkownikom na ciągłą informację na temat tego, co dokładnie się dzieje, i przeprowadzenie na bieżąco dostosowania projektu tak, aby zmierzał w kierunku pożądanych celów.
EN
The paper describes the project management by SCRUM, APF, xPM. Presented management of IT projects involving the conduct of the project along its optimal rate, which develops during the project, which allows users to continuous information on the, what exactly is going on and carry on an ongoing basis to adapt the project so that it aimed in the direction of the desired objectives.
4
Content available remote Realization of a Shunt Active Power Filter with Improved Dynamic Performance
84%
EN
This paper describes the realization of a modified shunt active power filter (APF) with improved dynamic performance. The control circuit is realized using the floating-point digital signal processor TMS320F28335. An analog input circuit and a synchronization circuit are described too. In the proposed circuit transient performance of APF is improved using non-causal predictive current compensation and modified output inverter. According to this modification the APF dynamics are improved.
PL
W artykule opisano realizację energetycznego równoległego filtru aktywnego (APF) z polepszonymi właściwościami dynamicznymi. W układzie sterowania zastosowano zmiennoprzecinkowy procesor sygnałowy TMS320F28335. Opisano analogowy układ wejściowy i układ synchronizacji. W filtrze zastosowano dwa rozwiązania poprawiające właściwości dynamiczne: nieprzyczynowy algorytm sterowania i zmodyfikowany układ falownika wyjściowego. Modyfikacji pozwalają na polepszenie właściwości dynamicznych filtru.
5
Content available remote Wykorzystanie urządzeń energoelektronicznych w systemie elektroenergetycznym
84%
PL
W artykule przedstawiono układy energoelektroniczne umożliwiające kontrolę przesyłu mocy (UPFC), poprawę jakości energii (APF) i kompensację składowych nieaktywnych prądu (SVC, STATCOM). Przedstawiono najważniejsze różnice między układami energoelektronicznymi a układami z elementami pasywnymi (L,C).
EN
The application of power electronics to the control of power flow (Unified Power Flow Controller), energy quality (Active Power Filter) and compensation non active power (Static Var Compensator, STATCOM) are presents in the paper. The most important differences between equipment with passive elements (L,C) and power electronics were described.
6
Content available Improving Power Quality in AC Supply Grids
84%
EN
This paper describes a digital and actual model of the UPQC (Unified Power Quality Conditioner) integrated system for power quality improvement. The UPQC’s design and its connection to an AC supply grid, 1-phase and 3-phase alike, provide effective compensation of unwanted interferences in the waveforms of load supply voltages and non-linear load currents. This article presents an overview of topologies and control strategies. The study of the UPQC confirmed its positive impact on the power quality. The electricity parameters were significantly improved. Total harmonic distortion in supply voltage THDu decreased six-fold to  1.89%, and total harmonic distortion in load current THDi decreased more than ten-fold to  2.38% for a  non-linear load (uncontrolled bridge rectifier with load L). Additionally, symmetrisation of supply voltages and reactive power compensation Q of linear load was obtained. The UPQC integrated system for power quality improvement can be used wherever high-quality and PN-EN 50160 standard – compliant electricity is required.
PL
W artykule opisano model cyfrowy i rzeczywisty zintegrowanego układu do poprawy jakości energii elektrycznej UPQC (ang. Unified Power Quality Conditioner). Budowa układu UPQC oraz sposób jego dołączenia do sieci zasilającej prądu przemiennego, zarówno 1-fazowej, jak i 3-fazowej, umożliwiają skuteczną kompensację niepożądanych zakłóceń występujących w przebiegach napięć zasilających odbiorniki, jak i prądach pobieranych przez nieliniowe odbiorniki. W artykule przedstawiono przegląd topologii oraz strategii sterowania. Przeprowadzone badania układu UPQC potwierdziły jego pozytywny wpływ na jakość energii elektrycznej. Uzyskano istotną poprawę parametrów energii elektrycznej. Współczynnik zawartości wyższych harmonicznych w napięciu zasilającym THDu (ang. Total Harmonic Distortion Voltage) zmniejszył się sześciokrotnie do wartości 1,89%, współczynnik zawartości wyższych harmonicznych w prądzie odbiornika THDi (ang. Total Harmonic Distortion Current) zmniejszył się ponad dziesięciokrotnie, do 2,38% dla odbiornika nieliniowego (niesterowany prostownik mostkowy z obciążeniem L). Dodatkowo uzyskano symetryzację napięć zasilających oraz kompensację mocy biernej Q odbiornika liniowego. Zintegrowany układ do poprawy jakości energii elektrycznej UPQC może być stosowany wszędzie tam, gdzie wymagana jest energia elektryczna o wysokiej jakości, spełniająca wymagania normy PN-EN 50160.
EN
A design method about how to design main circuits of active power filters(APF) with hybrid cascade multilevel structure is proposed in this paper. Through careful research, the combination of these cascade H-bridge modules is properly chosen and the number of high-frequency module is reasonably selected. Following eight steps described in the paper, a reasonable design process of the combination of these modules can be Got easily for a given condition. Through the reasonable combination of hybrid cascaded modules made up of high and low voltage devices, the design method that how to design the main circuit of this APF can be used to different voltage class in moderate voltage grid. Simulation results validate the rightness of the proposed method.
PL
W artykule przedstawiono zastosowanie hybrydowego kaskadowego wielopoziomowego układu w aktywnym filtrze mocy (ang. Active Power Filter). Opisany został sposób doboru modułów wykorzystanych mostków typu H oraz wyniki symulacyjne układu.
EN
The paper includes a summary and a background of long-time research conducted by a research team in the Institute of Electrical Engineering and Computer Science at SilesianUniversity of Technology. The researchwork has principally been related to selected problems in the field of analysis and synthesis of systems aimed at symmetrisation and improvement of some power quality parameters. This paper constitutes a first part of the report on the research. It has been devoted to effective elimination of higher harmonics and reactive power compensation by means of parallel active power filters. The other problem discussed in this paper is related to this issue and it is very important from the economic point of view; it addresses optimal sizing and placement of active power filters in investigated power networks.
PL
W artykule przestawiono przykład zastosowania energetycznego filtru aktywnego (EFA) do poprawy właściwości pasywnych filtrów wyższych harmonicznych. Rozwiązanie to, nazywane hybrydowym energetycznym filtrem aktywnym, ma za zadanie połączenie zalet obu rozwiązań z jednoczesnym obniżeniem mocy pozornej układu EFA. W pracy przedstawiono analizę przykładowego rozwiązania a wnioski poparto symulacjami.
EN
This paper presents an example of Active Power Filters (APF) used for improving of properties of higher order harmonic passive filters. This solution, called Hybrid Active Power Filter, combines advantages of both methods and allows to reduce apparent power of APF. An analysis of one of possible solutions has been presented. The paper presents the analysis of a demonstrational solution and its conclusions are supported by simulations.
EN
Artificial Potential Filed (APF) is the most well-known method that is used in mobile robot path planning, however, the shortcoming is that the local minima. To overcome this issue, we present a deadlock free APF based path planning algorithm for mobile robot navigation. The Proposed-APF (P-APF) algorithm searches the goal point in unknown 2D environments. This method is capable of escaping from deadlock and non-reachability problems of mobile robot navigation. In this method, the effective front-face obstacle information associated with the velocity direction is used to modify the Traditional APF (T-APF) algorithm. This modification solves the deadlock problem that the T-APF algorithm often converges to local minima. The proposed algorithm is explained in details and to show the effectiveness of the proposed approach, the simulation experiments were carried out in the MATLAB environment. Furthermore, the numerical analysis of the proposed approach is given to prove a deadlock free motion of the mobile robot.
11
67%
EN
This paper presents the survey of the smart grid technologies, including the background, motivation and practical applications. The driving forces for the smart grid technologies are presented, including the blackout, global energy crisis and environmental protection requirement. The key technology issues for building the smart grid are discussed. The crucial elements of the smart grid and their applications are introduced, including the un-interruptible power supply (UPS), adaptive var compensator (AVC), static synchronous compensator (STATCOM), active power filter (APF), unified power quality conditioner (UPQC), micro-grid, solar and wind generation, and high voltage direct current (HVDC) transmission technologies.
PL
Artykuł prezentuje przegląd technologii smart grid”. Uwzględniono takie zjawiska jak blackout, globalny kryzys energetyczny i zalecenia ochrony środowiska. Omówiono podstawowe elementy sieci „smart grid” i jej zastosowania, uwzględniając systemy UPS, AVC, STATCOM, APF, UPQC, źródła słoneczne i wiatrowe oraz technologię transmisji napięcia stałego HVDC.
12
59%
PL
W artykule przedstawiono zmodyfikowany układ wyjściowy równoległego filtru aktywnego (APF). Dzięki tej modyfikacji poprawie uległy właściwości dynamiczne filtru APF. Pokazane zostały wyniki symulacji takiego filtru aktywnego wykonane przy pomocy programu Matlab.
EN
This paper describes the proposed active power filter (APF) with a modified output inverter. According to this modification the APF dynamics is improved. The simulation results using program Matlab of such APF are also presented in the paper.
PL
W artykule przedstawiono koncepcję pacy równoległej energetycznego filtru aktywnego (EFA) oraz hybrydowego energetycznego filtru aktywnego (HEFA) w 3-fazowym systemie energetycznym mocy z odbiornikiem symetrycznym. Celem działania filtrów jest eliminacja harmonicznych prądu źródła ora kompensacja mocy biernej w układzie źródło-odbiornik, przy założonym racjonalnym podziale zadań filtracyjnych pomiędzy filtrami. Filtry zasymulowano w środowiskach MATLAB-Simulink oraz OrCAD-Capture&PSpice z użyciem interfejsu SLPS.
EN
In the paper the conception of parallel running of active power filter (APF) and hybrid active power filter (HAPF) in 3-phase energetic power system with balanced load was presented. Aim of filters running is elimination of source current harmonics and compensation of reactive power in source-load system, with assumed efficient division of filtering task between both filters. Filters was simulated in MATLAB-Simulink and OrCAD-Capturel&PSpice environment using SLPS interface.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.