Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  środowisko kwaśne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
100%
EN
The paper outlines the course of corrosion processes in magnesium and Mg-Li alloys. The methodology of corrosion studies of alloys for plastic forming and their chemical composition as well as micrographs of alloys intended for research are presented.
2
Content available remote Badania trwałości betonu cementowego w środowisku kwasowym
84%
PL
Mimo że beton jest uważany za materiał mało kwasoodporny, istnieje potrzeba testowania i oceny trwałości betonu z różnymi spoiwami w agresywnym środowisku kwasów. W artykule przedstawiono ocenę odporności betonów z dwoma rodzajami cementu na działanie kwasu solnego. Ze względu na brak odpowiednich procedur normowych wszystkie testy zostały przeprowadzone zgodnie z własną procedurą ZIMBPW. Próbki wyeksponowano na działanie kwasu o różnym stężeniu i w różnym czasie ekspozycji. Jako kryteria oceny kwasoodporności przyjęto: zmianę masy, zmianę wytrzymałości na ściskanie i zginanie.
EN
Although concrete is hardly considered as the acid resistant material, it should be possible to test and evaluate the ability of concrete of various cements to resist the chemically aggressive environments. The paper presents assessment of the resistance of concretes with two types of cement to hydrochloric acid. Due to the lack of proper standard procedures all tests were performed according to the DBME own procedure: specimens were exposed to acids of various concentrations and for various exposure times. Concrete acid resistance evaluation criteria were: change ofmass, change of compressive and flexural strength.
|
2004
|
tom R. 60, nr 5
265-271
PL
Zbadano efekty technologiczne procesu dwustopniowego rozjaśniania świerkowych mas termomechanicznych nadtlenkiem wodoru w środowisku kwaśnym i alkalicznym. Dokonano oceny wpływu pH i temperatury roztworu rozjaśniającego, ilości dozowanego nadtlenku oraz czasu obróbki na wskaźniki chemiczno-technologiczne rozjaśniania w środowisku kwaśnym. Porównano efektywność obróbki jednostopniowej w środowisku alkalicznym i dwustopniowej prowadzonej w obecności katalizatora miedziowego w środowisku kwaśnym oraz stabilizatorów siarczanu magnezu i krzemianu sodu w środowisku alkalicznym. Stwierdzono, iż dwustopniowa obróbka nadtlenkiem wodoru w środowisku kwaśnym i alkalicznym, umożliwia otrzymywanie świerkowych mas termomechanicznych o podwyższonej białości, z porównywalną wydajnością i przy mniejszym zużyciu nadtlenku wodoru w porównaniu do tradycyjnego jednostopniowego rozjaśniania w środowisku alkalicznym.
EN
The technological efficiency of two stage brightening of the spruce TMP with hydrogen peroxide under acidic and alkaline conditions has been studied. The influence of pH and temperature of the brightening solution, peroxide charge and time of treatment on chemical and technological indices of process under acidic conditions was evaluated. The effects of one stage alkaline hydrogen peroxide treatment in comparison with two stage sequence, initially under acidic conditions in the presence of copper catalyst, followed by alkaline conditions with addition of stabilizers magnesium sulphate and sodium silicate were examined. The results of this study show that two stage brightening of the spruce TMP with hydrogen peroxide under acidic and alkaline conditions has beneficial effect first of all on peroxide consumption than on brightness response and does not affect the yield when compared to standard one stage alkaline peroxide treatment.
4
Content available remote Korozihja betonu konstrukcihjj v seredovihshhih kislot
84%
EN
The paper is devoted to the investigation of the concrete corrosion procedure with the effect of the hydrochloric and sulfuric acids. There is the aggressive acid environment in the most industrial buildings of the chemical industry and galvanic shops. Thus investigation of the corrosion procedures in such environments are very important. The article presents the experimental results of the mass loss, the flexural strength and the compressive strength of the concrete specimens, which depends on the effect of the aggressive environments and time. The paper contains as well the results of studying of qualitative concrete composition and microstructure of the concrete. The testing was performed upon the plain concrete and concrete with antirust coating, namely by silicorganical varnish. The efficiency of the antirust coating with the effect of the aggressive acid environment is also defined.
PL
Przedstawiono wyniki badań termicznej dekompozycji fragmentów obwodu drukowanego z podzespołami elektronicznymi prowadzonej w reaktorze z pęcherzowym złożem fluidalnym, oraz ługowania produktów spalania w środowisku kwaśnym. Uzyskaną po spaleniu pozostałość poddano dwuetapowej ekstrakcji w środowisku kwaśnym (H₂SO₄ i woda królewska). Uzyskano stopnie ekstrakcji wynoszące od 99,95% (Cu) do 97,42% (Mn), dla ołowiu (2,60%), przy użyciu H₂SO₄, oraz od 99,94% (Cu) do 71,73% (Ti) przy użyciu H₂SO₄ i wody królewskiej. Warunkiem uzyskania wysokich stopni ekstrakcji przy użyciu kwasu siarkowego było zastosowanie w początkowym okresie tego procesu kwasu stężonego.
EN
Printed circuit boards with electronic components were combusted in a fluidized bed reactor in air-liq. petroleum gas stream. The combustion products were leached with concd. H₂SO₄ and HNO₃/H₂SO₄ at 50°C for 120 min. The metal recovering degree ranged from 99.95% (Cu) to 97.42% (Mn), with the exception of lead (2.60%), when H₂SO₄ was used, and from 99.94% (Cu) to 71.73% (Ti) when in a 2-stage process H₂SO₄ and HNO₃/H₂SO₄ were used.
EN
The main issue of the article is the corrosion of the reinforced concrete elements by the co-influence of the aggressive and power factors. The problem of corrosion is extremely actual one. Therefore the tests were carried out upon the specimens considering the corrosion in the acid environment, namely 10 % H2SO4. The acid environment H2SO4 was taken as a model of the aggressive environment. Conclusions concerning the corrosion model of the cross section and investigation of stress-strain state have been made. That material concerns the problem of the reinforced concrete corrosion as a whole construction. Reinforced concrete beams were tested with and without the co-action of the aggressive environment and power factor.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.