Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
100%
EN
The Lorentzian width of the spectral line Hel 504.7 nm emitted in the negative glow of a hollow cathode discharge (HCD) was found to increase depending on the distance from the emitting volume to the cathode axis. This effect manifests itself at low buffer gas pressures pHe E[epsolon](0.0-0.28) Torr. The later is typical for the experiments on SFS, radiative width and other constants. Thus, the observed radial inhomogeneity concerns the accuracy of these measurements. It is checked by determination of radiative width of the Hel 504.7 nm line emitted by two regions along the radius of HCD.
EN
Based on the excitation space anisotropy a partial polarisation of the spontaneous emission is found in hollow cathode discharge. This polarisation is ascribed to existing spontaneous coherence, i. e., self-alignment of the excited states. The aligning factors are the beam-like fast electrons from the cathode dark space. An expression for observed signal of the spontaneous emission magnetic depolarisation is obtained. Withim the frames of the ordinary opto-galvanic effect a separate coherent conductivity is analysed. a poor coherent conductivity due the self-aligned states is detected.
3
Content available remote Anomalous optogalvanic signal : spectrometric applications
63%
EN
Along with the conventional optogalvanic (OG) signal an anomalous ligh-induced response has been detected in hollow cathode discharge. This response manifests itself both in the amplitude and time-resolved OG reactions. The anomalous OG signal is found to be less dependent on the absorbing optical transition and yet, more informative on the parameters of the plasma medium, that is the OG detector. This circumstance is proposed for usage in four applications based on the behaviour of the anomalous OG signal. The latter is taken as a spectral marker, as an amplified quasi-amplitude signal as well as a sensitive tool in monitoring procedure.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.