tom Vol. 53, nr 9
770--775
EN
The numerical modelling of groundwater flow and pollutant transport was performed for the old sanitary landfill surrounded by a vertical bentonite barrier. The recirculation system of leachate applied on the landfill was also included in transport modelling. The simulation, using FEMWATER software, aimed at assessment of the vertical bentonite barrier influence on shaping of groundwater level in subsoil on surroundings, as well as estimating the infiltration time of leachate in the waste body during recirculation. The results of groundwater monitoring were used for verification and calibration of the numerical model.
PL
W ramach drugiej linii metra w Warszawie wykonanych będzie dwadzieścia osiem stacji, z których trzynaście zlokalizowano na terenie wysoczyzny polodowcowej, pozostałe w dolinie Wisły. W pierwszej kolejności realizowany jest jej centralny odcinek o długości 6 km, na którym zbudowanych zostanie 7 stacji: Rondo Daszyńskiego, Rondo ONZ, Świętokrzyska, Nowy Świat, Powiśle, Stadion i Dworzec Wileński. Prezentowany przykład badań modelowych przepływu wody podziemnej wykonano na potrzeby wspomagania projektowania wykopu stacji B-10 Rondo Daszyńskiego. Wykop o głębokości 20 m będzie zagłębiony do 5 m poniżej stropu użytkowego poziomu wodonośnego. Wstępna koncepcja wykonania wykopu zakładała odwadnianie z jego wnętrza, w osłonie ścian szczelinowych wykonanych do głębokości 10 m poniżej dna wykopu. Wyniki badań modelowych miały odpowiedzieć na dwa następujące pytania: (1) jak będzie kształtował się wydatek odwodnienia wykopu? i (2) czy ściany szczelinowe na tyle wystarczająco ograniczą lej depresji związany z odwodnieniem wykopu, aby nie doszło do osiadania podłoża gruntowego pod istniejącymi obiektami budowlanymi? Do obliczeń symulacyjnych odwodnienia wykopu i przepływu wód podziemnych w jego rejonie wykorzystano program numeryczny FEMWATER – A three-demensional finite element computer model for simulating density-dependent flow and transport in variably saturated media z pakietu GMS (Groundwater Modeling System). Obliczenia wykonano dla rozważanego wariantu głębokości wykonania ściany szczelinowej – do głębokości 10 m oraz jako porównawcze, do głębokości 5 i 15 m poniżej dna wykopu. Pomimo uwzględnienia w badaniach ścian szczelinowych, z prognozy uzyskano znaczne wydatki odwodnienia wykopu i obniżenie ciśnienia hydrostatycznego w gruncie otaczającym wykop, co może stanowić zagrożenie dla zasobów wód podziemnych oraz zagrożenie dla pobliskich budynków w wyniku osiadania podłoża. Wyniki prognozy mogą skłonić inwestora do podjęcia decyzji o realizacji wykopu z zastosowaniem bariery iniekcyjnej w strefie między ścianami szczelinowymi.
EN
Within the Second Subway Line 28 stations will be constructed, 13 of them are localized on the postglacial plateau area and the rest of them in Vistula Valley. At the first stage, central part of subway line of 6 km long, consisting of 7 stations, i.e. Rondo Daszyńskiego, Rondo ONZ, Świętokrzyska, Nowy Świat, Stadion and Dworzec Wileński, has been constructed. The paper presents the example of groundwater flow modeling for the design of the pit station B-10 named Rondo Daszyńskiego. The pit station of the depth of 20 m, will be immersed below the roof of usable aquifer. Preliminary conception of the pit excavation assumed dewatering its inside with the use of cut-off walls to the depth of 10 m below pit bottom. The modeling were performed to answer two following questions: (1) what will be the discharge capacity during dewatering? and (2) will cut-off walls reduce the depression cone to protect subsoil settlement under existing buildings? The numerical modeling of the pit excavation dewatering was performed with the use of FEMWATER numerical program – A Three-Dimensional Finite Element Computer Model for Simulation Density-Dependent Flow and Transport in Variably Saturated Media from the range of GMS (Groundwater Modeling System). The simulation was performed for the case of 10 m depth of cut-off walls and additionally for the depth of 5 and 15 m below the pit bottom. Despite that cut-off wall was taken into account, simulation results indicated considerable discharge capacity and decreasing of piezometric pressure in surroundings. These can be dangerous for groundwater resources and settlement of nearest buildings subsoil. The results of modeling can make the decision to realize the station pit with the lateral injection barrier in the zone between cut-off walls.
PL
W artykule przedstawiono przykład numerycznego modelowania przepływu wód podziemnych podczas odwadniania odkrywki kopalni węgla brunatnego. Zapewnienie wystarczającej kubatury dla gruntów z nadkładu węgla jest konieczne dla dalszej eksploatacji KWB "Turów". Model FEMWATER zwałowiska nadkładu z kopalni opracowano dla numerycznego rozwiązania przepływu wód podziemnych dla projektu rozwoju zwałowiska wewnętrznego w tej kopalni. Podstawą rozwiązania numerycznego był problem przepływu opisany równaniami Richarda w ujęciu trójwymiarowym, z zastosowaniem metody elementów skończonych. Głównym celem przeprowadzonego modelowania była prognoza podtopień (zawodnienia) zwałowiska nadkładu i jego bezpośredniego otoczenia. Wyniki badań modelowych przepływu wód podziemnych zostaną wykorzystane do projektu rozbudowy systemu odwodnienia odkrywki i zwałowiska oraz rozbudowy monitoringu potencjalnych zagrożeń stateczności skarp zwałowiska w sąsiedztwie obiektów chronionych. Główne obiekty podlegające zabezpieczeniu w rejonie projektowanego zwałowiska to: filar Nysy Łużyckiej, droga międzynarodowa Trzcinie-Sieniawka oraz zaplecze techniczne i magazynowe kopalni. Wyniki modelowania będą również wykorzystane do zaprojektowania technicznych zabezpieczeń zwałowiska w rejonie tych obiektów.
EN
The paper presents the example of numerical modelling of groundwater flow during dewatering of excavation in the lignite open pit mine. Sufficient cubic capacity for overburden soils is necessary to continue operation of the lignite mine in Turów site. The FEMWATER model of the overburden bank from the lignite open pit mine consists computer solution of groundwater flow for the design of the overburden heap in this site. The basis of numerical solution was the problem of groundwater flow described by Richard's equation, using 3-D finite elements method. The main, sophisticated purpose of the modelling carried out, taking into consideration this model, was the prediction of underflooding of the overburden bank and its surroundings. Modelling test results of the groundwater flow will be applied for extension of dewatering system and the design of monitoring system of potential threat of the overburden bank stability, constructed in the close vicinity of protected objects. The main objects which need special protection during overburden bank construction and dewatering are: the bank of Nysa Łużycka River, international road and industrial infrastructure around TURÓW lignite open mine. The modelling results also will be applied in designing of adequate technical safety solutions to protect these objects.
|
|
tom nr 4
232-239
PL
Charakterystyka stacji metra w Warszawie i warunków hydrogeologicznych wokół stacji. Opis numerycznego modelu przepływu wód podziemnych oraz odwodnienia wykopu stacji metra. Symulacje numeryczne wpływu odwodnienia wykopu i zasięgu leja depresji zwierciadeł dwóch poziomów wodonośnych.
EN
Description of the metro station in Warsaw and hydrogeological conditions around the station. Description of numerical model applied for a groundwater flow and dewatering of the excavation for the station. Numerical simulations of excavation dewatering impact and the range of depression cone of phreatic surfaces of two aquifers.