Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Ograniczanie wyników
Czasopisma help
Lata help
Autorzy help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 144

Liczba wyników na stronie
first rewind previous Strona / 8 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 8 next fast forward last
EN
The article "Public greenery as part of urban composition on the example of Wroclaw and Copenhagen," discusses the problem of the composition of urban landscape with particular reference to plant material in a relationship with the surrounding architecture. The introductory part presents the psychological and philosophical aspect of the above-mentioned theme, including an analysis and explanation of the terms "perception" and "space". Then there are mentioned spatial elements that affect the observer and their impact on the reception way of environment by people living in urban areas. The next chapter is the presentation of systems of green in the composition of the city and the introduction in the shaping of green in relation to architecture. There is raised a point of floors, walls and ceiling in the shaping of urban space and interiors and openings in the urban landscape. Summary is a presentation of examples of compositional-spatial solutions observed on areas of Wroclaw and Copenhagen.
EN
The main goal of this article is to investigate sustainable urban development of the Central European city (Wrocław/Poland) through an environmental engineering application of SUDS (Sustainable Urban Drainage Systems) measures to managing stormwater in city sections with various land use in the same watershed area (the Ślęża River Valley). The author presents a study made in three different parts of the city (single housing district – Oporów, multihousing district – Nowy Dwór, public service district – Stadion), which were constructed in different historical periods. The analyses were supported by city masterplan, GIS software (Quantum GIS 1.7.4) and calculations made according to up-to-date specific regulations. They demonstrate the current sustainable stormwater management scenarios for areas of different land use, historical periods and function in the city. The proposed research method aims to compare sustainable urban development of the new urban district with the quarters, which had been built before the term “sustainability” became common in water and land development practice. The conducted study can be practically used as a supportive tool for urban planning authorities in Poland. The paper investigates a novel in the Polish realities method of assessment sustainability of the area through green infrastructure application in district scale.
PL
Celem pracy była analiza procesu urbanizacyjnego Wrocławia w kontekście zrównoważonego rozwoju poprzez symulację gospodarowania wodą opadową w skali dzielnicy. Do celów badawczych wybrano trzy charakterystyczne rodzaje zabudowy miasta z różnych okresów historycznych (Oporów – zabudowa jednorodzinna, Nowy Dwór – zabudowa wielorodzinna, Stadion – teren usługowy), znajdujące się w zlewni rzeki Ślęza. W celu przeprowadzenia analiz wykonano wektoryzację obszarów za pomocą oprogramowania Quantum GIS (1.7.4) oraz aktualizowanych map Systemu Informacji Przestrzennej Wrocławia dostępnych w serwisie internetowym. Sklasyfikowano wszelkie powierzchnie nieprzepuszczalne, tj. nawierzchnie utwardzone, pokrycia dachowe. Za potencjalne składowe zielonej infrastruktury uznano natomiast powierzchnie przepuszczalne, tj. obszary wegetacyjne, nawierzchnie przepuszczalne, zielone dachy. W obliczeniach porównawczych posłużono się wartościami współczynników spływu według polskiej normy PN-92/B-0170. Dodatkowo, w ocenie zielonych dachów ekstensywnych, wykorzystano współczynnik spływu według opracowań amerykańskich. Badanie przepuszczalności wybranych trzech obszarów wzdłuż rzeki Ślęza w granicach Wrocławia wykazało duże możliwości kształtowania zrównoważonej gospodarki wodnej tych terenów poprzez zastosowanie elementów zielonej infrastruktury.
PL
W artykule poruszono problematykę doboru rozwiązań wykorzystywanych w procesie automatyzacji sieci SN z perspektywy najbardziej istotnych kryteriów, decydujących o efektywności inteligentnych sieci elektroenergetycznych.
EN
This article presents the problematic aspects of selection solutions in the medium voltage grid automation concerning the most important criteria determining the effectiveness of smart grid.
|
2010
|
tom nr 3 (68)
72-75
PL
Artykuł prezentuje system połączeń sprężynowych produkowany przez firmę WAGO. Zagadnienie opracowano z teoretycznego punktu widzenia, jak również w aspekcie zastosowania systemu przy budowie i modernizacji obiektów energetycznych.
EN
The article is showing the spring connections system created by WAGO. The problem is presented of the theoretical point of view as well as the requirements place for modernized or constructed energy objects.
EN
Many studies have shown the adverse effects of perfluorinated compounds (PFCs) on living organisms. PFCs include groups of perfluorinated sulfonic acids, perfluorinated carboxylic acids, fluorotelomer alcohols, high-molecular weight fluoropolymers and low-molecular weight perfluoroalkanamides. These compounds are chemically very stable and are highly resistant to biological degradation. Currently, humans are at increased risk as PFCs are resistant to hydrolysis, photolysis, microbial degradation, or metabolism, and their estimated elimination half-life is about 3.8 years. Therefore, the scale of the bioaccumulation of PFCs in humans is not fully known. Our review provides basic information regarding the chemical nature of PFCs, their production, and use, as well as the current European Union legislation. A special focus was put on the sources of food contamination by PFCs, toxicological studies, estimation of human exposure to PFCs, and tolerable daily intake. At present, there is no legislation for perfluorinated compounds in food of plant and animal origin within the European Union.
|
|
tom R. 15, nr 9
231-238
PL
Celem pracy było określenie wpływu temperatury czynnika suszącego, średniej średnicy kropel surowca, strumienia masy surowca i powietrza - na wielkość strumienia wody z jednostki objętości komory suszenia w suszarce rozpyłowej APV ANHYDRO LAB1. Wyniki pozwoliły na sformułowanie liczb podobieństwa modelowego opisujących wymianę masy w komorze suszenia.
EN
The purpose of the study was to determine the influence of drying factor temperature, average diameter of a material drop, material and air mass stream on the size of water stream out of a volume unit of drying chamber in the APV ANHYDRO LAB1 spray drier. The results allowed for determining model similarity numbers describing mass exchange in the drying chamber.
9
Content available remote Torsion of precast hollow core slabs
63%
EN
Pretensioned hollow core slabs are one of the most widely applied precast elements in the modern building industry all over the world. Due to the possibility of their use under various support or loading conditions, these elements repeatedly work under a complex stress state. Theoretical analysis of the phenomena of the interaction of shear and torsion in the above-mentioned HC elements is presented. The theoretical basis and design regulations of the computational model included in code PN-EN 1168+A3:2011 along with parametrical analysis of that model are demonstrated. The largest experimental research program of hollow-core slabs under shear and torsion conducted thus far is also briefly described – this study was carried out in Finland in 2004 and was the basis for the development and calibration of the numerical computational model formulated in Chalmers University of Technology in Göteborg, Sweden.
PL
Strunobetonowe płyty kanałowe są jednym z najczęściej stosowanych stropowych elementów prefabrykowanych na świecie. Ze względu na możliwość funkcjonowania płyt w różnych warunkach podparcia czy obciążenia niejednokrotnie elementy te pracują w złożonym stanie naprężenia. W artykule przedstawiono analizę teoretyczną zjawiska interakcji skręcania ze ścinaniem poprzecznym w rozważanych elementach. Zaprezentowano podstawy teoretyczne i wytyczne projektowe modelu obliczeniowego zawartego w normie PN-EN 1168+A3:2011 wraz z analizą parametryczną modelu. Skrótowo opisano również największe dotychczas zrealizowane badania doświadczalne ścinanych i skręcanych płyt, zrealizowane w 2004 roku w Finlandii, które posłużyły do opracowania i kalibracji numerycznego modelu obliczeniowego wykonanego w Chalmers University of Technology w Göteborgu.
PL
Stropy Slim Floor (SF), to konstrukcje z płyt kanałowych (HC) opartych na smukłych belkach, w których wysokość dźwigara zazwyczaj nieznacznie przekracza wysokość prefabrykatu stropowego. Wraz ze wzrostem ugięcia podpór następuje deformacja układu płyt stropowych, w konsekwencji czego w prefabrykacie pojawiają się dodatkowe poprzeczne naprężenia normalne i styczne, mogące spowodować ukośne zarysowanie i w konsekwencji zniszczenie zewnętrznych żeberek płyt. Może również dojść do podłużnego zarysowania dolnej powierzchni płyty. Pomimo częstych realizacji tego typu konstrukcji, w obowiązującej normie EN 1168 znalazł się jedynie lakoniczny zapis o potrzebie uwzględnienia redukcji obliczeniowej nośności na ścinanie - nie podano jednak żadnej procedury obliczeniowej. Powszechnie uważa się, że zmniejszenie niekorzystnego wpływu stycznych naprężeń ścinających w żeberku płyty można osiągnąć poprzez wypełnienie betonem kanałów w skrajnych fragmentach płyty HC lub ułożenie monolitycznej warstwy nadbetonu. Wytyczne fib są praktycznie jedynym dokumentem pozwalającym określić nośność stropów SF z uwzględnieniem wpływu nadbetonu lub wypełnienia kanałów – w referacie skrótowo opisano ten model obliczeniowy. W celu określenia wpływu nadbetonu na pracę sprężonych płyt HC na podporach podatnych, wykonano szereg analiz obliczeniowych uwzględniających m.in. wpływ grubości nadbetonu, wartość współczynnika tarcia między nadbetonem a prefabrykatem, kolejności betonowania styków pionowych i warstwy nadbetonu, a także ilości zbrojenia w betonie uzupełniającym. Wyniki przeprowadzonych obliczeń, wraz z wnioskami z nich wynikającymi, przedstawiono w niniejszym artykule.
EN
Slim Floors (SF) are the structures made of the Hollow Core (HC) slabs supported on the slender beams, where the beam height is usually slightly greater than the height of precast slab element. With the increase of the supports' deflection, the deformation of the HC slab occurs, and in consequence, additional transverse normal and shear stresses appear in the precast element, which can cause a diagonal cracking and destruction of external webs of this element. It may also result in longitudinal cracks on bottom surface of the slab. Despite the frequent implementation of this type of structures, the existing standard EN 1168 gave only a brief record of the need to take the reduction in design shear capacity into account, but is not given any calculation procedure. It is widely believed that reduction of unfavourable effects of shear stress in the HC slab’s web can be achieved by filling the cores with concrete or arrangement of the monolithic layer or concrete topping. The fib guidelines are practically the only one document which allows to determine the shear capacity of SF slabs, including the influence of concrete topping or core filling – brief description of this design model is presented in the paper. In order to determine the effect of concrete topping on the behaviour of prestressed HC slabs on the flexible supports, a number of calculation analyzes were performed, which take into account the effects of thickness of the concrete topping, the value of the friction coefficient between the concrete topping and the precast element, the sequence of concreting of vertical joints and topping layer and the amount of supplementary reinforcement in the topping. The results of the calculations, and the conclusions derived from them, are presented in the article.
14
Content available remote Composite action of precast hollow core slabs with structural topping
63%
EN
There is no interface reinforcement in composite floors made of HC slabs covered with structural topping. In such structures, the preparation of the top surface of the precast element has a major influence on longitudinal shear strength. The recommendations of various codes concerning the bearing capacity of the non-reinforced joint in concrete composite structures are presented in this paper. The results of the authors’ own computational analysis have been compared with the results of experimental tests carried out by different research institutions. Calculations according to Eurocode 2 underrate the value of the bearing capacity. A much stronger conformity of the results was achieved for the calculations carried out according to previously existing standards or according to information given in Model Code 2010.
PL
W stropach zespolonych, wykonywanych z płyt HC z nadbetonem konstrukcyjnym, nie stosuje się zbrojenia zszywającego w złączu. W tych konstrukcjach przygotowanie powierzchni górnej prefabrykatu ma zasadniczy wpływ na nośność styku na ścinanie. W artykule przedstawiono zlecenia różnych dokumentów normowych w zakresie nośności niezbrojonego złącza w betonowych konstrukcjach zespolonych. Wyniki własnych analiz obliczeniowych porównano z rezultatami badań doświadczalnych prowadzonych w różnych ośrodkach naukowych. Obliczenia według Eurokodu 2 dają zaniżone wartości nośności. Dużo lepszą zgodność obliczeń z wynikami badań uzyskuje się dla obliczeń prowadzonych według wcześniej obowiązujących przepisów lub informacji zawartych w Model Code 2010.
|
|
tom Nr 1
42--52
PL
Artykuł prezentuje zagadnienie wpływu podatności dźwigarów na nośność na ścinanie strunobetonowych płyt kanałowych. W celu wyznaczenia wartości strumienia sił ścinających, powodujących wystąpienia poziomych naprężeń stycznych τ2 , prowadzona jest analiza teoretyczna w oparciu o autorski model pasmowy konstrukcji zespolonej dźwigar – płyta. Model stanowi, jak dotąd, pierwszą próbę analitycznego uwzględnienia wpływu podatności żeberek płyty oraz warunków oparcia płyt na dźwigarze za pośrednictwem podkładek neoprenowych na zmianę nośności na ścinanie. Zagadnienie to jest zupełnie pominięte w innych modelach obliczeniowych, np. w modelu fib, którego wyniki są również prezentowane.
EN
The paper concentrates on the influence of support flexibility on the shear capacity of prestressed hollow core slabs. In order to determine the value the shear flow, which causes the horizontal shear stresses τ2 , the theoretical analysis was carried out. It was based on the author’s two-beam model for a composite structure. So far the model is the first analytical attempt to take into account the influence of hollow core webs flexibility and support conditions with a neoprene tape on the shear capacity change. The issue is entirely omitted in other design models, e.g. in the fib model, which results are also presented in the paper.
PL
Przedstawiono sposoby rozwiązywania trudnego zagadnienia projektowego, jakim jest oszacowanie redukcji nośności strunobetonowych płyt kanałowych opartych na belkach wiotkich. Rozważany problem w Polsce nie został ujęty w ramy zapisów normowych lub wytycznych. W artykule syntetycznie przedstawiono zapisy wytycznych niemieckich dotyczące tego rodzaju konstrukcji, które mogą być stosowane w praktyce inżynierskiej.
EN
The methods of solving difficult design issues related to the estimation of the reduction level of the load capacity of precast prestressed hollow core slabs on flexible beams are presented in the paper. In Poland, this issue have not been included in the specific framework of standards or transparent guidelines so far. The German guidelines for this type of structures, which can be easily applied in engineering practice, are briefly discussed in the paper.
17
Content available remote Strunobetonowe stropy gęstożebrowe - badania w skali rzeczywistej
63%
PL
W artykule opisane zostały badania doświadczalne gęstożebrowych stropów belkowo-pustakowych, których podstawowymi elementami nośnymi są belki strunobetonowe, wykonywane bez jakiegokolwiek zbrojenia poprzecznego. Odpowiednie zespolenie belek z betonem uzupełniającym gwarantowane jest przez faliste ukształtowanie ich powierzchni górnej. Kompleksowe badania objęły zarówno zagadnienie zespolenia między belką a nadbetonem, jak i pracę płyt badanych w skali rzeczywistej, w schematach statycznych odpowiednich dla zginania i ścinania. W artykule przedstawione zostały wyniki przeprowadzonych badań, ze szczególnym uwzględnieniem modeli zniszczenia, a także porównanie osiągniętych wartości nośności z obliczeniową nośnością systemu stropowego, wyznaczoną zgodnie z nowowprowadzonymi w Polsce normami europejskimi.
EN
The paper describes the experimental research on beam-and-block floor systems. The test floor system is characterized by pretensioned concrete beams without any shear reinforcement. The composite action between the beams and cast in-situ concrete is guaranteed by the complementary shape of the corrugated top surface. Composite action between the precast beam and cast in situ concrete, as well as the behavior of floor system elements in real scale in the schemes suitable for bending and shear were tested. The article presents results of the research, with particular emphasis on failure models, and compares the values of obtained capacity with the design load capacity of the floor system, calculated according to the newly introduced in Poland European codes.
18
Content available remote Shear capacity of prestressed hollow core slabs on flexible supports
63%
EN
It is widely believed that reduction of unfavorable effects of shear stress in the HC slab’s web can be achieved by filling the cores with concrete or through the arrangement of the monolithic layer or concrete topping. The fib guidelines are practically the only document which allows for determining the shear capacity of HC slabs, including the influence of concrete topping or core filling – a description of this design model and the calculation analysis are presented in the paper. In order to determine the effect of concrete topping on the behaviour of prestressed HC slabs on flexible supports, a number of calculation analyses were performed. The results of the calculations and the conclusions resulting from it are presented in the paper.
PL
Powszechnie uważa się, że zmniejszenie niekorzystnego wpływu stycznych naprężeń ścinających w żeberku płyty można osiągnąć poprzez wypełnienie betonem kanałów w skrajnych fragmentach płyty HC lub ułożenie monolitycznej warstwy nadbetonu. Wytyczne fib są praktycznie jedynym dokumentem pozwalającym określić nośność stropów SF z uwzględnieniem wpływu nadbetonu lub wypełnienia kanałów – w artykule opisano ten model obliczeniowy. W celu określenia wpływu nadbetonu na pracę sprężonych płyt HC na podporach podatnych, wykonano szereg analiz obliczeniowych, których wyniki, wraz z wnioskami z nich wynikającymi, przedstawiono w niniejszym artykule.
EN
Results of crosses between Hordeum bulbosum (2x) and H. vulgare (2x) are presented. Nine H. vulgare genotypes of different crossability with H. bulbosum were treated both as female and male parents. Immature embryos were cultured in vitro according to ADAMSKI and SURMA (1994). Seeds set, embryo development and obtained haploid plants were recorded. It was shown that seed setting and haploid plant efficiency (haploids/100 florets) were about ten times lower in H. bulbosum x H. vulgare than in H. vulgare × H. bulbosum The cvs. Vada, Apex and the doubled haploid line KA7/3 (related to Apex) which showed a low crossability in H. vulgare × H. bulbosum, gave a relatively high seed setting in reciprocal crosses. The obtained results indicate that partial incompatibility of some H. vulgare genotypes with H. bulbosum could be cytoplasmatically influenced.
first rewind previous Strona / 8 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.