Learning mechanisms determining fish reproduction are particularly beneficial in the case of experimental work on juvenile forms of fish making research independent of the season of the year. This paper describes the reproduction method of the round goby, Neogobius melanostomus, under controlled conditions. This species is not native to the ichthyofauna of the Gulf of Gdańsk and was discovered here for the first time in 1990. In the case of pre-seasonal reproduction of the round goby, the first spawning took place 5 weeks after the beginning of thermal stimulation. On the other hand, artificial reproduction of the fish caught in the spring was possible after only a week of being kept in a temperature of 17-19°C. The spawn incubation period ranged from 17 to 22 days, depending on the temperature. For natural spawning, the period from spawning to hatching was 18-19 days, at a constant temperature of 20°C.
PL
Poznanie mechanizmów warunkujących rozród ryb jest szczególnie korzystne w przypadku prac doświadczalnych na formach juwenilnych ryb, gdyż uniezależnia prowadzenie badań od pory roku. Praca opisuje metodę rozrodu babki byczej N. melanostomus w warunkach kontrolowanych. Gatunek ten nie jest rodzimym składnikiem ichtiofauny Zatoki Gdańskiej i został tu po raz pierwszy stwierdzony w 1990 roku. W przypadku przedsezonowego rozrodu babki byczej pierwszego tarła doszło po 5 tygodniach od rozpoczęcia stymulacji termicznej. Sztuczny rozród ryb odłowionych na wiosnę był natomiast możliwy już po tygodniu przetrzymywania w temperaturze 17-19 °C. Okres inkubacji ikry wynosił od 17 do 22 dni w zależności od temperatury. Dla tarła naturalnego czas od tarła do wylęgu wynosił 18-19 dni przy stałej temperaturze 20 °C.
Przedstawiono analizę wpływu miejsca wyładowania piorunowego w urządzenie piorunochronne obiektu na poziom zagrożenia piorunowego instalacji elektrycznej.
EN
The paper presents analysis of influence of place of atmospheric discharge at lightning protection device of the object on the level of risk to electric installation.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Ocena poprawności zastosowanych rozwiązań ochrony odgromowej wymaga określenia podziału prądu udarowego pomiędzy instalacje przewodzące dochodzące do obiektu a system uziomowy podczas bezpośredniego wyładowania piorunowego w obiekt. Dotyczy to szczególnie tej części prądu, która wpływa do instalacji elektrycznej. Posiadając informacje o wartości szczytowej i kształcie tego prądu można poprawnie dobrać urządzenia ograniczające przepięcia oraz określić poziomy przepięć dochodzących do przyłączy zasilających urządzeń.
EN
Correctness estimation of lightning protection solutions require definition of lightning current distribution in conductive installations entering the structure and in earthing system during direct lightning strike to this structure. It concerns particularly this part of lightning current, which flows in electric installation. Information about this current gives the possibility to estimate the levels of overvoltages on the equipment’s ports and correctly choose SPDs.
The goal of the paper was to simplify the designing process for mass and energy flow through solar collector - chimney system. Theoretical analysis allowed to get involved system of three nonlinear analytical equations in dimensionless forms that have been saved. Dimensionless numbers for the problem are well known in the literature on fluid mechanics and thermodynamics: Reynolds, Grashof, Galileo, Biot and Prandtl. In the analyzed equations are also dimensionless geometric parameters expressing the ratios of basic geometrical dimensions of the collector system-chimney: the radius disc collector to the thickness gap, the height and radius of the chimney. In the system of equations, the Reynolds number is treated as the determined number, which is a novelty of the method used.
PL
Przepływ powietrza przez system kolektor słoneczny i komin, opisano w pracy stacjonarnymi równaniami zachowania: pędu (równanie Naviera-Stokesa), masy i energii, które następnie rozwiązano analitycznie przy spełnieniu warunków brzegowych: zanikanie prędkości powietrza na powierzchniach wewnętrznych tarcz kolektora i komina. Teoretyczna analiza pozwoliła uzyskać układ trzech uwikłanych nieliniowych analitycznych równań, które zapisano w postaciach bezwymiarowych. Liczbami bezwymiarowymi w rozwiązywanym problemie są dobrze znane w literaturze dotyczącej mechaniki płynów i termodynamiki liczby: Reynoldsa, Grashofa, Galileusza, Biota i Prandtla. W analizowanych równaniach występują też geometryczne parametry bezwymiarowe wyrażające stosunki podstawowych wymiarów geometrycznych systemu kolektor-komin: promień tarczy kolektora, szerokość szczeliny, wysokość i promień komina. W przedstawionym układzie równań liczba Reynoldsa traktowana jest jako liczba określana, co jest nowością stosowanej metody, a nie jak zazwyczaj bywa zadaną liczbą określającą zjawisko. Obliczanie jej dla danych warunków zewnętrznych i geometrycznych komina pozwala stosunkowo łatwo obliczyć pozostałe szukane wielkości jak prędkości powietrza wlotowego do kolektora i w kominie, rozkład temperatury powietrza w szczelinie i kominie. Otrzymane wielkości pozwalają ostatecznie określić moc badanego systemu kolektor słoneczny-komin. Przedstawiona metoda obliczeniowa porządkuje dotychczasowy sposób projektowania kolektorów słonecznych i może być pomocna dla projektantów inżynierów energetyków.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.