Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article presents spiritual guidance, startchestvo in the Eastern Churches. On the basis of two sayings of the Desert Fathers the author carried out a moral analysis of two spiritual starets’ behavior. Based on this analysis behavioral and moral norms were determined which regulated starets’ activities. We presented problems which can be observed in spiritual guidance when a starets violates the norms in relation to his supervisees. We pointed out that this violation in pastoral ministry can be caused by the phenomenon called “mock startchestvo”.
EN
A variety of clustering validation indices (CVIs) are aimed at validating the results of clustering analysis and determining which clustering algorithm performs best. Different validation indices may be appropriate for different clustering algorithms or partition dissimilarity measures; however, the best suitable index to use in practice remains unknown. A single CVI is generally unable to handle the wide variability and scalability of the data and cope successfully with all the contexts. Therefore, one of the popular approaches is to use a combination of multiple CVIs and fuse their votes into the final decision. This work aims to analyze the majority-based decision fusion method. Thus, the experimental work consisted of designing and implementing the NbClust majority-based decision fusion method and then evaluating the CVIs performance with different clustering algorithms and dissimilarity measures to discover the best validation configuration. Moreover, the authors proposed to enhance the standard majority-based decision fusion method with straightforward rules for the maximum efficiency of the validation procedure. The result showed that the designed enhanced method with an invasive validation configuration could cope with almost all data sets (99%) with different experimental factors (density, dimensionality, number of clusters, etc.).
PL
Różnorodne indeksy walidacji klasteryzacji (CVI) mają na celu walidację wyników analizy skupień i określenie, który algorytm klasteryzacji działa najlepiej. Różne indeksy walidacji mogą być odpowiednie dla różnych algorytmów klasteryzacji lub miar niepodobieństwa podziału; jednak najlepszy walidacyjny indeks do zastosowania w praktyce pozostaje nieznany. Pojedynczy CVI na ogół nie jest w stanie poradzić sobie z dużą zmiennością i skalowalnością danych oraz z powodzeniem poradzić sobie we wszystkich kontekstach. Dlatego jednym z popularnych podejść jest użycie kombinacji wielu CVIs i połączenie ich głosów w ostateczną decyzję. Celem tej pracy jest analiza metody fuzji decyzji opartej na większości. W związku z tym prace eksperymentalne polegały na zaprojektowaniu i wdrożeniu metody NbClust fuzji decyzji opartej na większości, a następnie ocenianie wydajności CVIs za pomocą różnych algorytmów klasteryzacji i miar niepodobieństwa w celu odkrycia najlepszej konfiguracji walidacji. Ponadto autor zaproponował rozszerzenie standardowej metody fuzji decyzji oparta na większości o proste reguły dla maksymalnej efektywności procedury walidacji. Wynik pokazał, że zaprojektowana ulepszona metoda z inwazyjną konfiguracją walidacji może poradzić sobie z prawie wszystkimi zbiorami danych (99%) z różnymi eksperymentalnymi parametrami (gęstość, wymiarowość, liczba klastrów itp.).
PL
W artykule przedstawiono zasadę działania, projekt i sposób obliczania elementów zasilacza do układów krzemowych fotopowielaczy (SiPM). Zasilacz jest skompensowany termicznie i wyposażony w analogowe wejście do regulacji napięcia wyjściowego. Podano i omówiono wyniki testów zbudowanego egzemplarza.
EN
This article presents the design, principle of operation and the method of calculating component values of power supply designed for silicon photomultipliers (SiPM). The power supply is thermally compensated and equipped with an analog input to regulate the output voltage. The results of the tests of the constructed prototype are presented and discussed.
4
100%
EN
Combinatorial optimization challenges are rooted in real-life problems, continuous optimization problems, discrete optimization problems and other significant problems in telecommunications which include, for example, routing, design of communication networks and load balancing. Load balancing applies to distributed systems and is used for managing web clusters. It allows to forward the load between web servers, using several scheduling algorithms. The main motivation for the study is the fact that combinatorial optimization problems can be solved by applying optimization algorithms. These algorithms include ant colony optimization (ACO), honey bee (HB) and multi-objective optimization (MOO). ACO and HB algorithms are inspired by the foraging behavior of ants and bees which use the process to locate and gather food. However, these two algorithms have been suggested to handle optimization problems with a single-objective. In this context, ACO and HB have to be adjusted to multiobjective optimization problems. This paper provides a summary of the surveyed optimization algorithms and discusses the adaptations of these three algorithms. This is pursued by a detailed analysis and a comparison of three major scheduling techniques mentioned above, as well as three other, new algorithms (resulting from the combination of the aforementioned techniques) used to efficiently handle load balancing issues.
PL
W artykule przedstawiono wady znanej metody korelacji dla oszacowania opóźnienia czasowego. Wykazano, że metoda korelacji dla pomiaru prędkości przepływu w oparciu o obrazy tomograficzne otrzymane za pomocą dwupłaszczyznowego tomografu elektrycznego ma poważne ograniczenia w praktyce, zwłaszcza gdy przepływ przebiega w postaci tzw. korków. Podstawowym problemem jest niestacjonarność mierzonych danych, dlatego wymóg korelacji danych wejściowych nie jest spełniony. Wykazano, że prędkość przepływu może być mierzona wówczas gdy funkcja korelacji wzajemnej obliczona na podstawie danych wejściowych posiada globalne maksimum. Zaproponowano oryginalny algorytm automatycznego określania interwałów czasowych do obliczania prędkości przepływu. Pokazano, że algorytm pozwala obliczyć prędkość przepływu we właściwy sposób. Przedstawiono wyniki obliczeń prędkości przepływu przy użyciu proponowanej koncepcji reżimu dynamicznego przepływu gazu i ciała stałego.
EN
The article presents the disadvantages of the known correlation method for estimating time delay. It has been shown that the correlation method for measuring the flow velocity based on tomographic images obtained with a two-plane electrical tomography has serious limitations in practice, especially when the flow is in the plug regime case. The basic problem is the non-stationarity of the measured data, therefore the requirement to correlate the input data is not met. It has been shown that the flow rate can be measured when the data is suitable. An approach for determining the time intervals for calculating the flow velocity was proposed. It has been shown that the approach allows calculating the flow rate in the right way. The results of flow velocity calculations using the proposed concept of a dynamic gas and solid flow regime are presented. Although the proposed concept was verified for tomographic data only, the authors assume that it can be applied for measurement systems based on other modalities, for example, gamma-ray measurement and other systems which employed a cross-correlation function.
EN
Liquid-gas flows in pipelines appear in many industrial processes, e.g. in the nuclear, mining, and oil industry. The gamma-absorption technique is one of the methods that can be successfully applied to study such flows. This paper presents the use of the gamma-absorption method to determine the water-air flow parameters in a horizontal pipeline. Three flow types were studied in this work: plug, transitional plug-bubble, and bubble one. In the research, a radiometric set consisting of two Am-241 sources and two NaI(TI) scintillation detectors have been applied. Based on the analysis of the signals from both scintillation detectors, the gas phase velocity was calculated using the cross-correlation method (CCM). The signal from one detector was used to determine the void fraction and to recognise the flow regime. In the latter case, a Multi-Layer Perceptron-type artificial neural network (ANN) was applied. To reduce the number of signal features, the principal component analysis (PCA) was used. The expanded uncertainties of gas velocity and void fraction obtained for the flow types studied in this paper did not exceed 4.3% and 7.4% respectively. All three types of analyzed flows were recognised with 100% accuracy. Results of the experiments confirm the usefulness of the gamma-ray absorption method in combination with radiometric signal analysis by CCM and ANN with PCA for comprehensive analysis of liquid-gas flow in the pipeline.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.