Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Correlation analysis of clinical test data for diabetes mellitus type 2 patients
100%
EN
The present study deals with the application of correlation analysis as an option for assessment of clinical data from diabetes mellitus type 2 patients. One hundred clinical cases of patients are considered as object of the statistical treatment, each one of them characterized by 34 various clinical parameters. The go al of the study was to find patterns of correlation between the clinical tests. Each group of correlated indices is interpreted revealing specific aspects of the data structure. Relevant explanation of the correlation is found based on the patterns of correlation for parameters determining glucose level, anthropometric data, enzyme level, liver function, kidney function etc. It is assumed that this correlation could be of help in optimizing the performance of clinical test for this type of patients and for designing a pattern for the role of the different groups of test in determining of the metabolic syndrome of the patients.
PL
Zastosowano analizę korelacyjną jako metodę wspomagającą ocenę danych klinicznych pacjentów chorujących na cukrzycę typu 2. Badaniami objęto stu pacjentów, każdy z nich został scharakteryzowany za pomocą 34 różnych parametrów klinicznych. Celem badań było znalezienie struktur w korelacjach pomiędzy wynikami testów klinicznych. Każda skorelowana grupa pokazuje specyficzne aspekty struktur danych. Korelacje wyjaśniono na podstawie znalezionych struktur w korelacjach pomiędzy poziomem cukru we krwi, danymi antropometrycznymi, poziomem enzymów, funkcjami wątroby i nerek i in. Wydaje się, że korelacje te pomogą lepszemu wykorzystaniu testów klinicznych dla tego typu pacjentów oraz w projektowaniu grup testów do określania zespołów metabolicznych pacjentów.
EN
An investigation is made for dissolution of the copper and sulphide sulphur (Ss) from pyrite cinders, obtained from pyrite concentrates of ASSAREL-MEDET mine. Water solutions of H2S04-Fe2(S04)3 were used as a solvent. It was established that a satisfactory purification from the two elements was achieved when the pyrite cinders were obtained by roasting in a stable technological regime and were characterized with moderate content of Ss, within the limits of 1 to 2 percent by weight. The optimal conditions for the hydroprocess were found to be characterized with the following parameters: temperature - 365 K, composition of the solution - 20 g/1 H2S04 and 5 g/l Fe3+, duration of the treatment 8+10 h. In these conditions about 80 % of the copper and 50-55 % of the Ss dissolved in the solution. The product obtained so is separated in two fractions, by a magnetic separation: a strong-magnetic fraction rich in magnetite, and a weak-magnetic fraction, rich in hematite. The copper in the strong-magnetic fraction is approximately twice more concentrated than in the weak-magnetic one. The content of Ss in the two fractions does not differ significantly.
PL
Zbadano rozpuszczanie miedzi i siarki siarczkowej (Ss) z wypałków pirytowych, otrzymywanych z koncentratów pirytowych kopalni ASSAREL-MEDET. Jako rozpuszczalnik stosowano wodne roztwory H2S04-Fe2(S04)3. Stwierdzono, że dostateczne oczyszczenie z tych dwóch pierwiastków osiąga się, gdy wypałki pirytowe były otrzymane przez prażenie w stabilnym reżimie technologicznym i charakteryzowały się umiarkowaną zawartością Ss, w granicach 1 do 2 procent wagowych. Znaleziono, że optymalnymi parametrami hydroprocesu są: temperatura - 365 K, skład roztworu - 20 g/l H2S04 i 5 g/1 Fe3+, okres traktowania 8-10 godz. W tych warunkach około 80 % miedzi i 50-55 % Ss rozpuszcza się w roztworze. Tak otrzymany produkt rozdzielono na dwie frakcje magnetyczną separacją: silnie magnetyczna frakcja, bogata w magnetyt, oraz słabo magnetyczna frakcja, bogata w hematyt. Stężenie miedzi w silnie magnetycznej frakcji jest około dwukrotnie wyższe niż w słabo magnetycznej. Różnica stężeń Ss w obu frakcjach jest nieznaczna.
first rewind previous Strona / 1 next fast forward last