Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Introduction: This paper examines office staff’s knowledge and obedience of rules of computer workstation ergonomics and assesses how physical activity and obedience of ergonomic rules affect the level of pain intensity reported by office staff included in the study. Material and methods: The study group consisted of 136 persons (94 female and 42 male) aged between 20 and 46 (average 44,5±12,6 years) working on computer workstations. Results. Approximately 50% of the study group were spending their free time actively (72 persons, 52,9%). Preferred forms of activity were as follows: walking (72,1%), cycling (58,1%) and physical exercise (26,5%). Results: It was found that higher rates of physical activity significantly reduced the intensity of the pain resulting from computer work. On the contrary, a statistically significant number of people occasionally involved in physical activity more often suffered the following symptoms: pain in the shoulders (p=0,0224), hips (p=0,0036) and feet (p=0,0458), and tingling and sensory loss in lower extremities (p<0,0001). It was found that study group members regularly involved in physical activity less often suffered from the pain in the shoulders (22,9% vs 50,0%,), hips (14,3% vs 44,7%,) and feet (17,1% vs 31,6%), and tingling and sensory loss in lower extremities (2,9% vs 36,8%) when compared to the group with occasional physical activity. Statistically significant lower incidence of pain was observed in the study group members conforming to the rules of ergonomics at work as exemplified through the following symptoms: increased muscle tension in the shoulder areas (38,5% vs 61,8%, p=0,0303), pain in the upper parts of the spine (26,9% vs 50,9%, p=0,0274), eye pain, tearing and burning sensation (57,7% vs 80,0%, p=0,0170). Conclusions: 1. Only a small number of study group members complied with ergonomic rules at work. 2 It was observed that physical activity has a positive effect on pain reduction. 3. Adherence to ergonomic rules at work has a significant influence on reduction of pain intensity in examined groups.
EN
Introduction: The aim of this study was to evaluate the level of physical activity, quality of life, anxiety, stress and depression in patients after implantation of cardioverterdefibrillator (ICD) who have experienced or not the incident electrical storm with multiple ICD interventions. Material and methods: There was 36 patients with ICD in aged from 39 to 83 years. Patients were divided into two groups: those who had a Storm (+) or no Storm (-) incident electrical storm. In the group Storm (+) significantly more often occurred loss of consciousness before ICD implantation and after discharge, than in the Storm (-). Results: Also frequently found problems with life energy and vigor, which may limit the opportunities gainful employment and doing housework. Other parameters of quality of life were not different between groups. The level of stress and week-long physical activity was similar in both groups. Conclusions: 1. The incidence of electrical storm in ICD patients significantly increases the level of anxiety and influences the occurrence of mild depressive symptoms. 2. Electrical storm does not affect the increase in the level of stress and the week-long physical activity. 3. Electrical Storms limits the opportunities gainful employment and doing housework. 4. Frequent loss of consciousness in patients prior to ICD may indicate an increase in the frequency of electrical storms occurring after implantation of the device.
PL
Wprowadzenie: komorowa stymulacja resynchronizująca (CRT) ma zastosowanie w leczeniu chorych z ciężką niewydolnością serca. Cel: ocena wydolności fizycznej i jakości życia oraz zależności występujących pomiędzy badanymi parametrami u pacjentów po wszczepieniu CRT. Materiał i metody: do badań włączono 23 chorych (16 mężczyzn) w wieku 52-77 lat. Przed i po 6 miesiącach od wszczepienia wykonywano próbę spiroergometryczną 6-minutowy test korytarzowy oraz badano parametry jakości życia kwestionariuszem NHP. Analizowano korelacje pomiędzy wydolnością fizyczną a jakością życia. Wyniki: uzyskano istotne korelacje pomiędzy: VO2 a zaburzeniami snu r = 0,62 (p < 0,01) i ograniczeniami ruchowymi r = -0,54 (p < 0,05) przed zabiegiem, VO2 a bólem r = -0,82 (p < 0,02) i wyobcowaniem społecznym r = -0,90 (p < 0,005) po wszczepieniu CRT, dystansem marszu a poziomem energii r = -0,50 (p < 0,05) przed, a ból r = -0,87 (p < 0,05) po wszczepieniu CRT. Wnioski: 1. Zastosowanie komorowej stymulacji resynchronizującej poprawia istotnie wydolność fizyczną oraz niektóre aspekty jakości życia. 2. Pacjenci z wyższą wydolnością fizyczną lepiej oceniali niektóre aspekty jakości życia przed (poziom energii, ograniczenia ruchowe) i po (dolegliwości bólowe i wyobcowanie społeczne) implantacji CRT.
EN
Introduction: cardiac resynchronization therapy (CRT) is widely used in treatment of patients with congestive heart failure (CHF). Aim: evaluation of exercise tolerance and quality of life and their correlation in patients treated with cardiac resynchronization therapy (CRT). Materials and methods: 23 patients (16 men, mean age 63.0 ± 9.0 years) with CHF were included in the study. Cardiopulmonary exercise test, 6-minute corridor test were performed before CRT and after 6 months. All patients were examined by means of NHP QoL questionnaire. Results: statistically significant correlations between peak oxygen uptake (VO2) and sleep disorders (r = 0.62, p < 0.01) and physical exercise limitations before CRT (r = -0.54, p < 0.05) were observed. After CRT peak VO2 correlated negatively with pain (r = -0.82, p < 0.02) and social alienation (r = -0.90, p < 0.005). 6-minute walking test distance correlated significantly with energy level (r = -0.50, p < 0.05) before CRT and with pain after CRT (r = -0.87, p < 0.05). Conclusions: 1. CRT in CHF patients improves effort tolerance and some QoL aspects. 2. Patients with better physical exercise tolerance assessed some aspects of their QoL as better before CRT (energy level, physical limitations), and better after CRT (pain, social alienation).
EN
Background: Ultrasound measurement of the inferior vena cava diameter and its respiratory variability are amongst the predictors of fluid volume status. The primary purpose of the present study was to compare the consistency of inferior vena cava diameter measurements and the collapsibility index, obtained with convex and cardiac transducers. A secondary aim was to assess the agreement of the patient’s allocation to one of the two groups: “fluid responder” or “fluid non-responder”, based on inferior vena cava collapsibility index calculation made with two different probes. Methods: 20 experienced clinicians blinded to the purpose of the study analysed forty anonymized digital clips of images obtained during ultrasound examination of 20 patients. For each patient, one digital loop was recorded with a cardiac and the second with a convex probe. The participants were asked to determine the maximal and minimal diameters of the inferior vena cava in all presented films. An independent researcher performed a comparative analysis of the measurements conducted with both probes by all participants. The calculation of the collapsibility index and allocation to “fluid responder” or “fluid non-responder” group was performed at this stage of the study. Results: The comparison of measurements obtained with cardiac and convex probes showed no statistically significant differences in the measurements of the maximal and minimal dimensions and in the collapsibility index. We also noticed that the decision of allocation to the “fluid responder” or “non-responder” group was not probe-dependent. Conclusion: Both transducers can be used interchangeably for the estimation of the studied dimensions.
PL
Wprowadzenie: Nie prowadzono jeszcze za pomocą ultrasonografii szeroko zakrojonych badań nad wewnętrznymi wymiarami anatomicznymi szyi i ich zależnościami po wprowadzeniu u pacjenta przyrządu do zapewniania drożności dróg oddechowych umieszczanego na zewnątrz nagłośni. Na podstawie zbiorowych doświadczeń autorów związanych z analizą zewnętrznych wymiarów anatomicznych oraz oceną wewnętrznych wymiarów anatomicznych z wykorzystaniem innych technik przyjęto za cel zbadanie za pomocą ultrasonografii wewnętrznych wymiarów anatomicznych szyi oraz ich zmian związanych z użyciem maski krtaniowej LMA Unique. Metody: Do obserwacyjnego badania pilotażowego zakwalifikowano pacjentów nieotyłych, bez cech nieprawidłowości dróg oddechowych. Dokonano pomiaru zewnętrznych wymiarów anatomicznych szyi za pomocą zwalidowanej i ustandaryzowanej metody z wykorzystaniem taśmy mierniczej. Pod kontrolą ultrasonografii dokonano też pomiaru ośmiu wewnętrznych wymiarów anatomicznych, które według hipotezy badawczej odpowiadały zewnętrznym wymiarom anatomicznym. Po optymalnym umiejscowieniu i napompowaniu mankietu maski krtaniowej LMA-U dokonano ponownego pomiaru wewnętrznych wymiarów anatomicznych. Wyniki: W badaniu wzięło udział sześć osób. Stwierdzono, że wartości odległości gnykowo-bródkowej, odległości tarczowo-pierścieniowej, wysokości tarczowej oraz szerokości tarczowej wyznaczone na podstawie pomiaru taśmą mierniczą były przeszacowane w stopniu istotnym statystycznie (p < 0,05). Wymiary anatomiczne szyi w płaszczyźnie strzałkowej, takie jak wysokość tarczowa, odległość mostkowo-bródkowa oraz odległość tarczowo-pierścieniowa, uległy znacznemu zmniejszeniu po wprowadzeniu maski krtaniowej Unique. Wnioski: Zastosowanie maski krtaniowej Unique powodowało znaczne zmiany w anatomii wewnętrznej szyi. Powstałe zmiany i odpowiadające im wewnętrzne wymiary anatomiczne szyi mogą być pomocne w opracowywaniu sprzętu, który mógłby odpowiednio modyfikować swój kształt w obszarach największych odkształceń. Choć pomiary zewnętrznych wymiarów anatomicznych szyi skutkują przeszacowaniem odpowiadających im wymiarów wewnętrznych, jak donosili wcześniej autorzy niniejszej pracy, stopień zgodności każdego z pomiarów oraz ich współczynnik konwersji mogą być nadal pomocne w dobieraniu rozmiaru maski krtaniowej LMA-U. Ze względu na pilotażowy charakter pracy wskazane są dalsze badania. Artykuł w wersji polskojęzycznej jest dostępny na stronie http://jultrason.pl/index.php/issues/volume-17-no-71
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.