This paper proposes two novel reliability indexes for HVDC and a risk evaluation system for quantifying the risk brought by HVDC outage. Based on a proactive and preventive strategy of maintenance arrangement, the paper puts forward the “Power Availability” index to correct the situation that Energy Availability leads to inconsistent problems with power system reliability and security in the process of application. Then, the paper introduces the quantitative evaluation method which provides an effective analysis tool for scheduling department to arrange maintenance during the appropriate time by judging the operation risk. Based on this method, the index of “Active Planned Energy Unavailability” is put forward in order to encourage the scheduling department to arrange maintenance initiatively according to the power grid risk. It could change and improve the maintenance mode of HVDC using the guiding role of the reliability index. Blend the proposed new index into the original reliability index system of HVDC, sphere of application and the assessment objects will not only be limited to the equipment department and the dispatching department, power grid corporations will also be involved. Finally, this paper chooses the China Southern Power Grid as the simulation and analysis case. The results demonstrate a practical application of the proposed procedure and method.
PL
Niniejszy artykuł proponuje dwa oryginalne wskaźniki niezawodności dla linii wysokiego napięcia prądu stałego (HVDC) oraz system oceny ryzyka dla kwantyfikacji ryzyka na skutek przerw w dostawie HVDC. W oparciu o aktywną i prewencyjną strategię konserwacji, artykuł proponuje wskaźnik „Power Availability (Dostępności mocy)” w celu naprawy sytuacji, gdy Dostępność Energii prowadzi do niespójnych problemów z niezawodnością systemu elektroenergetycznego i bezpieczeństwem w procesie eksploatacji. Następnie artykuł wprowadza metodę oceny ilościowej, który zapewnia skuteczne narzędzie analizy dla działu planowania tak, aby można było zarządzać konserwację we właściwym momencie dzięki odpowiedniej ocenie ryzyka operacyjnego. Na bazie tej metody, zaproponowano wskaźnik „Aktywnego planowania niedostępności energii” w celu zachęcenia działu planowania do ustalania konserwacji zgodnej z poziomem ryzyka sieci energetycznej. Może to zmienić i poprawić tryb konserwacji HVDC za pomocą wskaźnika niezawodności. Proponowany nowy wskaźnik mógłby zostać wprowadzony do pierwotnego systemu wskaźników niezawodności HVDC i mógłby znaleźć zastosowanie i służyć ocenie obiektów nie tylko w działach sprzętu i dziale dyspozytorskim ale także w firmach eksploatujących sieci energetyczne. Na potrzeby symulacji i analizy, artykuł omawia przedsiębiorstwo China Southern Power Grid. Wyniki pokazują praktyczne zastosowanie proponowanej procedury i metody.
2
Content available remote Data-driven Valued Tolerance Relation Based on the Extended Rough Set
80%
EN
The classical rough set theory is based on the conventional indiscernibility relation. It is not very good for analyzing incomplete information. Some successful extended rough set models based on different non-equivalence relations have been proposed. The valued tolerance relation is such an extended model of classical rough set theory. However, the general calculation method of tolerance degree needs to know the prior probability distribution of an information system in advance, and it is also difficult to select a suitable threshold. In this paper, a data-driven valued tolerance relation (DVT) is proposed to solve this problem based on the idea of data-driven data mining. The new calculation method of tolerance degree and the auto-selection method of threshold do not require any prior domain knowledge except the data set. Some properties about the DVT are analyzed. Experiment results show that the DVT can get better and more stable classification results than other extended models of the classical rough set theory.
EN
Background: The aim of the study was to probe the morphological features of the proximal segment (V1) of vertebral artery (VA) in a sample of Chinese cadavers. Materials and methods: The origin, course and outer diameter at origin of the pre-vertebral part of the VAs were evaluated in 119 adult cadavers. Results: It was found that 94.12% of the VAs originated from the subclavian arteries, bilaterally. The variant origins were present in 5.88% of the cadavers and all originated directly from the arch of the aorta. All the variations were observed on the left side of male cadavers. The average outer diameters at origin of the normal and variation groups were 4.35 ± 1.00 mm and 4.82 ± 1.42 mm, respectively, p = 0.035. In the normal group, but not in the variation group, the average diameter in the males was significantly larger than that in the females (4.50 ± 0.99 mm, 3.92 ± 0.92 mm, respectively, p = 0.000). In addition, only 5 cadavers in the normal group had hypoplastic VAs (4.20%, 4 males, 3 right-sided). Vertebral artery dominance (VAD) was present in 91 (69 males) out of 112 cadavers and more common on the left (n = 48). In addition, 3 cadavers satisfied conditions for coexistence of VAD and vertebral artery hypoplasia. All 7 cadavers in the variation group exhibited VAD, which was more common on the right side (n = 5). Conclusions: The morphologic variations and frequencies described above have implications for the early prevention, abnormal anatomy detection, accurate diagnosis, safe surgery and endovascular treatment of cardiovascular and neurological disease. (Folia Morphol 2019; 78, 4: 710–719)