Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 41

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
EN
On the basis of audit surveys concerning modernization of heating systems in middle-sized towns (of 16 to 65 thousand inhabitants), a technical-economic analysis as well as an ecological analysis of feasible investment projects were performed. The audit surveys concentrated mainly on 152 local low-temperature boiler houses with low emission sources in selected towns of the north-eastern Poland. The audit surveys mentioned above involved also measurements of the amounts of SO2 and particulate matter polluting the air. The fundamental purpose of the suggested modernization of the researched heating systems was to improve the very low operating efficiency of the boiler houses (mainly with low emission sources) under concern, as well as - or perhaps above all - to reduce levels of SO2 and particulate matter polluting the air. One of the criteria applied in the economic assessment of the suggested projects (investments) was the Net Present Value (NPV), whereas in the case of the ecological assessment - reducing air pollution.
PL
Na podstawie opracowań dotyczących modernizacji gospodarki cieplnej w miastach średniej wielkości (od 16 do 65 tysięcy mieszkańców) przeprowadzono analizę techniczno-ekonomiczną oraz ekologiczną możliwych do zrealizowania przedsięwzięć modernizacyjnych. Opracowania audytorskie dotyczyły głównie lokalnych kotłowni niskotemperaturowych (152 kotłownie) z niskimi emitorami w wybranych miastach w północno-wschodnim rejonie Polski. W ramach ww. opracowań wykonano również pomiary zanieczyszczeń powietrza SO2 oraz pyłami. Zasadniczym celem zaproponowanych modernizacji systemów ciepłowniczych było poprawienie bardzo niskich sprawności eksploatacyjnych kotłowni, głównie z niskimi emitorami, a także (a może przede wszystkim) obniżenie zanieczyszczeń powietrza SO2 oraz pyłami. Jednym z kryteriów oceny ekonomicznej zaproponowanych przedsięwzięć (inwestycji) była Aktualna Wartość Netto (NPV), natomiast oceny ekologicznej - redukcja zanieczyszczeń powietrza.
PL
W referacie przedstawiono aktualną sytuację zarówno normalizacyjną, jaka zaistniała po wycofaniu w styczniu 1998 r. normy PN-91/02020 'Ochrona cieplna budynków'. Zaprezentowano nowe normy, jakie ukazały się lub ukażą w 1998 r., dotyczące zagadnień związanych z ochroną cieplną budynków.
EN
Present standarizatonal and legal situation which came to life after withdrawing the Standard PN-91/B-02020 'Thermal protection of buildings' in 1998, referring to thermal protection of buildings are presented.
5
Content available remote Przyczyny i konsekwencje niesprawnej wentylacji grawitacyjnej
100%
6
Content available remote Analiza modelu termicznego przemarzania gruntów wysadzinowych
100%
PL
W referacie przedstawiono analizę modelu termicznego przewodzenia ciepła w ośrodku gruntowym z uwzględnieniem warunku Stefana.
EN
Analysis of a thermal model of heat conduction in ground considering Stefan' s condition is presented in this paper.
8
Content available remote Zjawisko wysadziny zmarzlinowej - metody zapobiegania
100%
PL
Wysadzina zmarzlinowa to zjawisko polegające na podnoszeniu się ku górze powierzchni przemarzającej gruntu spoistego [gliny, ifu] wskutek zamarzania wody gruntowej podciąganej kapilarnie do strefy przemarzania, a dokładniej: na skutek kolejno tworzących się w podłożu soczewek lodu.
10
Content available remote Wpływ pojemności cieplnej na bilans cieplny budynku
100%
PL
W artykule przedstawiono analizę wpływu pojemności cieplnej Cm budynku mieszkalnego na współczynnik efektywności wykorzystania zysków ciepła w trybie ogrzewania ηH,gn, a w konsekwencji na zapotrzebowanie ciepła użytkowego do ogrzewania i wentylacji QH.nd. Podstawą analizy były wyniki wartości obliczeniowych zapotrzebowania na energię użytkową dla 7 przyjętych wariantów warstwy konstrukcyjnej ścian zewnętrznych i wewnętrznych przedmiotowego budynku. Obliczenia wykonano na podstawie aktualnie obowiązującej metodologii w sprawie charakterystyki energetycznej budynków.
EN
The paper presents analysis of the influence of thermal capacity Cm of apartment building on the coefficient of heat gain use efficiency during heating mode ηH,gn , and as a consequence on heat demand for heating and ventilation QH.nd. The results of calculation values of energy demand for 7 accepted variants of structural layers of external and internal walls in this building were analyzed. The calculations were conducted according to the methodology which is obligatory for preparing building energetic characteristics.
11
Content available remote Straty ciepła z budynku do gruntu
100%
PL
W referacie przedstawiono sposób obliczenia strumienia cieplnego do gruntu budynku będącego w kontakcie z gruntem. Obliczenia wykonano ze wspomaganiem komputerowym.
EN
The way of heat loss calculation of building elements situated directly on the ground is presented in this paper. The calculations were made with the aid of computer programmes.
12
Content available remote Rzeczywista głębokość przemarzania gruntu a wymagania normowe
100%
PL
Dane o maksymalnej głębokości przemarzania gruntów są niezbędne do celów inżynierskich m.in. przy posadowieniu fundamentów, przewodów wodociągowych, kanalizacyjnych itp. Wartości te w odniesieniu do terytorium Polski podaje polska norma PN-81/B-03020 w postaci mapy z izoliniami od 0,8 do 1,4 m, z zaleceniem, aby przewody wodociągowe, gazowe, kanalizacyjne posadawiać o % głębiej, niż wskazują podane wartości normowe. Izolinie zostały wyznaczone na podstawie wzoru zamieszczonego w normie radzieckiej NiTU-127-55, który został częściowo zmodyfikowany przez Wiłuna. Wzór ten uwzględnia tylko sumę średnich ujemnych temperatur miesięcy zimowych, nie uwzględnia natomiast tak istotnego czynnika jak rodzaj gruntu.
13
100%
PL
W artykule przedstawiono możliwości bezpiecznego posadowienia fundamentów budynków ogrzewanych na głębokość mniejszą niż głębokość położenie izotermy zero. Aby fundament nie był narażony na uszkodzenie w wyniku działania ujemnych temperatur, zaproponowano odpowiednią izolację termiczną. Dla zaproponowanej izolacji termicznej, korzystając z metod numerycznych, wykonano obliczenia rozkładu temperatur w otoczeniu fundamentów. Otrzymane wyniki zostały zweryfikowane badaniami bezpośrednimi.
EN
The article presents the possibility of safe placement of heated building foundations at depths deeper than the depth of the zero isotherm. In order for the foundation not to be susceptible to damage due to the influence of negative temperatures, suitable thermal insulation was proposed. The suggested thermal insulation was provided with calculations concerning the distribution of temperature values surrounding the foundations using numerical methods. The received results were verified by direct research.
16
Content available remote Kolektory słoneczne - analiza opłacalności
100%
PL
W artykule przedstawiono uwarunkowania ekonomiczne i techniczne wykorzystania energii słonecznej poprzez zastosowanie płaskich kolektorów cieczowych. Analizę przeprowadzono na przykładzie domu jednorodzinnego zlokalizowanego w Białymstoku.
PL
Zaprezentowano nowe normy, jakie ukazały się lub ukażą w 1999 roku, odnoszące się do zagadnień związanych z ochroną cieplną budynków.
EN
Present standardization and legal situation which came to life after withdrawing of the Standard PN-91/B-02020 'Thermal protection of buildings' an January 1998 is presented in the paper. New standards which were issued and will be issued in 1999, referring to thermal protection of buildings are presented.
19
Content available remote Efektywność ekonomiczna kolektorów słonecznych
100%
20
Content available remote Analiza zjawiska wysadziny zmarzlinowej dla celów inżynierskich
100%
PL
W artykule przedstawiono stan wiedzy na temat teorii powstawania wysadziny, najbardziej znane modele obliczeniowe oraz metody zapobiegania przed wysadziną.
EN
This work presents state of the art regarding theory of frost heave formation, the most known computational models, the methods of prevention against frost heaves.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.