Nowa wersja platformy, zawierająca wyłącznie zasoby pełnotekstowe, jest już dostępna.
Przejdź na https://bibliotekanauki.pl
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 22

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
|
2006
|
tom Vol. 80, nr 1
13-25
EN
Amodified distillation package, elaborated in the Institute of Physical Chemistry, Polish Academy of Sciences, has been used formodelling of the existing petroleum process. The package employes a local composition model NRTLmKW [1] for calculation of multicomponent VLE equilibria. The obtained results have been compared with results given by the use of the NRTL model and discussed from the point of view of its practical applications. Some recommendations have been made on the use of the distillation package for modelling and optimization of the industrial processes.
2
Content available Air separation in PVTMS membrane module
63%
|
2008
|
tom nr 4
101-112
EN
The air separation was carried out using Russian industrial (Kriogenmash) PVTMS membrane module. The investigations have been performed in a pilot plant scale installation especially designed for this purpose. The separation measurements have been done, at different pressure ratios, for four types of membrane module sets as follows: one membrane module; a set of two parallel membrane modules; a set of two serial membrane modules with permeate from the first one feeding the second module; and, a set of two serial membrane modules with retentate from the first one feeding the second module. Obtained separation results have been discussed from the point of view of efficiency and conditions of using PVTMS membrane modules for such purposes. The results have been also used for evaluation of quality and properties of the membrane module.
PL
Przeprowadzono separację powietrza w rosyjskim, przemysłowym (Kriogenmash), membranowym module PVTMS, w półtechnicznej skali, na specjalnie zaprojektowanej do tego celu aparaturze. Pomiary wykonano dla różnych stosunków ciśnień i czterech różnych układów modułów membranowych: pojedynczego modułu, układu dwóch równolegle połączonych modułów, układu dwóch szeregowo połączonych modułów, w którym moduł drugi był zasilany permeatem z modułu pierwszego oraz układu dwóch szeregowo połączonych modułów, w którym moduł drugi był zasilany retentatem z modułu pierwszego. Otrzymane wyniki doświadczalne zostały przedyskutowane z punktu widzenia warunków stosowania modułów PVTMS oraz wydajności prowadzonych procesów separacji powietrza. Ponadto, posłużyły one do określenia własności i jakości badanych modułów membranowych.
|
2010
|
tom nr 10
33-37
EN
In the paper the deep analysis of the use of membrane pressure processes for removal of sulphides and chromium from tannery wastewaters have been presented. Low- and medium pressure membrane processes like MF, UF, NF have been proposed for regeneration and water recirculation of both lime-sulphide and chromium tannery bath. It results in reduction of hazardous chemicals and water used in the tannery process. Only restrict dividing of tannery wastewater on non-chromium and chromium wastewater as well as proper selection of membrane cleaning procedure preventing its fouling can be assuring high efficiency of membrane processes.
EN
This paper presents a literature review concerning the possibility of minimizing the noxiousness of chromium tannery wastewater. Based on the comparison of different methods applied for removing chromium (III) ions from wastewater and water solutions, the special qualities of pressure membrane processes were found. The appropriate combination of pressure membrane processes enables one to obtain saline solutions that can be re-used during the tanning of skins.
PL
W pracy dokonano przeglądu literaturowego dotyczącego możliwości minimalizacji uciążliwości chromowych ścieków garbarskich. Na podstawie porównania różnych metod stosowanych do usuwania jonów chromu(III) ze ścieków i roztworów wodnych stwierdzono szczególne możliwości ciśnieniowych procesów membranowych. Polegają one na tym, że odpowiednie połączenie ciśnieniowych procesów membranowych umożliwia uzyskanie kąpieli soli, które mogą być ponownie użyte podczas garbowania skór.
EN
In this paper we present the new method that allows obtaining of super fine calcium carbonate particles in a (CO2 – Ca(OH)2 – H2O) system. A new rotating disc reactor was employed as a processing unit to run this multiphase process. The device enables to control inter- and intraface mass and energy transfer as well as the macro- and micromixing effects in the reacting system. The system can be controlled by the rate of discs revolutions speed and mixing conditions in the system, reagents contact area or gas flow rate. The influence of different parameters on the reaction kinetics and precipitated powders properties were investigated. Crystallites and agglomerates morphology was examined with the Scanning Electron Microscopy (SEM). The testing with X-ray diffraction analysis confirmed that we have obtained a pure calcite, which is the most thermodynamically stable polymorph of CaCO3.
PL
W artykule przedstawiono nową metodę otrzymywania bardzo drobnych krystalitów węglanu wapnia w systemie (CO2 – Ca(OH)2 – H2O). Do realizacji tego wielofazowego układu wykorzystano reaktor z wirującym dyskiem, co umożliwia wpływanie na procesy transportu masy i energii. Możliwe jest także wykorzystanie efektów makro- i mikromieszania. Na zachowanie systemu istotny wpływ mają takie dające się kontrolować czynniki jak szybkość obrotowa dysków, powierzchnia kontaktu reagentów, czy wielkość przepływu gazu. W artykule pokazano wpływ poszczególnych czynników na szybkość reakcji. Kształt i wielkość zarówno pojedynczych krystalitów, jak i aglomeratów badano z wykorzystaniem skaningowego mikroskopu elektronowego. Badania dyfrakcji rentgenowskiej potwierdziły, że w przeprowadzonych procesach otrzymywano czysty kalcyt, będący najbardziej trwałą termodynamicznie odmianą CaCO3.
EN
The impact of selected process parameters of an integrated NF/RO system on possibilities of the desalination of model solutions, containing salts in typical concentrations for flowback water from shale gas production, was analyzed in this work. Based on the results of studies carried out in the pilot scale, it was found that the integrated NF/RO system allows for satisfactory reduction of the model solution of flowback water mineralization. It can be stated that the use of NF/RO system enables the re-use of the “real” flowback water during hydraulic fracturing.
PL
W pracy zbadano wpływ wybranych parametrów procesowych zintegrowanego systemu NF/RO na możliwość odsalania modelowych roztworów zawierających sole w stężeniach charakterystycznych dla płynu powrotnego ze szczelinowania złóż gazu z łupków. Na podstawie otrzymanych wyników badań prowadzonych w skali pilotowej, stwierdzono, że zintegrowany układ NF/RO pozwala na zadowalające zmniejszenie mineralizacji roztworu modelowego płynu powrotnego. Można zatem założyć, iż zastosowanie układu NF/RO umożliwi ponowne wykorzystanie ścieku rzeczywistego podczas szczelinowania hydraulicznego.
EN
Membrane techniques used in tannery industry allow for application of close technological flows in separation processes. In present work we give a review concerning the membrane separation techniques applied for regeneration of exhausted tanning liquors. Economic evaluation of these applications is also presented.
EN
Polymeric nanoparticles containing nimesulide (NIM) were prepared by the emulsion solvent evaporation method. Biodegradable polymers were used as materials for nanoparticle formulations with the application of studies for the drug delivery sector in mind. Two analytical methods, scanning electron microscopy (SEM) and particle size analysis, were applied to investigate the obtained nanoparticles. Characteristic parameters were calculated to describe the amount of active pharmaceutical ingredient trapped in nanoparticles. The biological active substance release process was investigated under different conditions. The impact of various parameters [kind of polymer (PLA or PLGA), speed of mixing and especially of pH] is presented across our research.
PL
Polimerowe nanocząstki zawierające nimesulid (NIM) otrzymano metodą emulsyjną z odparowaniem rozpuszczalnika. Do ich wytworzenia wykorzystano biodegradowalne polimery. Wytworzone nanocząstki zbadano za pomocą skaningowej mikroskopii elektronowej (SEM) oraz analizatora wielkości cząstek. Obliczono charakterystyczne parametry opisujące ilość substancji farmaceutycznie aktywnej uwięzionej wewnątrz nanocząstek. Oceniono wpływ rodzaju polimeru stosowanego do kapsułkowania, szybkości mieszania suspensji, w szczególności pH środowiska na proces uwalniania substancji biologicznie czynnej.
PL
Podczas badań określono skuteczność czyszczenia membran NF za pomocą pojedynczych kąpieli myjących takich jak: kwas solny, wodorotlenek sodu, a także w zintegrowanym systemie dwustopniowego czyszczenia za pomocą kwasu solnego i wodorotlenku sodu. Jedynie zastosowanie dwustopniowego mycia membran NF umożliwia przywrócenie początkowych ich właściwości.
EN
The effectiveness of NF membranes’ cleaning by hydrochloric acid or sodium hydroxide baths and also in the integrated system of two-stage cleaning by hydrochloric acid and sodium hydroxide was analyzed in the paper. Only the two-stage cleaning of NF membranes enabled one to restore their initial properties.
PL
Podczas badań określono wpływ początkowego stężenia siarczanów obecnych w chromowych ściekach garbarskich na wydajność i efektywność rozdział filtrowanego roztworu na dwie kąpiele umożliwiając jego ponowne wykorzystanie. Stwierdzono, że wysokie początkowe stężenie siarczanów sprzyja łatwiejszemu przenikaniu jonów chlorkowych przez membranę do permeatu, ale przyczynia się również do wydłużenia czasu potrzebnego na uzyskanie założonego współczynnika zatężenia jonów chromu(III) w retentacie.
EN
The effect of sulphate concentration in chromium tannery wastewater on the productivity and effectiveness of the filtered solution enabling its distribution on two reusable baths was determined. The hight initial sulphate concentration supported the simpler permeation of chloride ions throught the membrane to permeate and also increased the time needed to obtain the defined rate of chromium(III) concentration factor in retentate.
EN
In the paper, the permeability of polymer nanofiltration membranes was analysed. The studies were carried out for the model wastewater chromium (III) solutions at pH 4. The model wastewater chromium (III) solutions were included different concentrations of NaCl, Na2SO4, and CrCl3 . It was found that on the membrane permeability is influenced by their morphology and electrostatic properties, regardless of the composition of the feed. The negative charge of the DL membrane was limited by the polarization of the membrane and the osmotic effect. This had a beneficial effect on the permeability of the DL membrane. It positively influenced the permeability of the membrane. For the HL membrane, it does not have a surface charge under the process conditions, and the electrostatic effect is not observed. The formation of the polarization layer and the osmotic effect is limited only to a small extent by the Donnan effect. Thus, a significantly higher permeability drop for the separated salt of solutions was observed for the HL membrane, despite its looser structure. In the case of the CK membrane, it increased the polarization of the membrane, because, under the process conditions, the membrane was positively charged. This caused a reduction in membrane permeability, practically excluding its use as a nanofiltration membrane for concentrating chromium in salt solutions. The presence of small amounts of chromium in the solution containing a fixed concentration of chlorides and sulphates resulted in a slight increase in the permeability of the DL membrane to the solutions of the salts themselves. In the case of the HL membrane, this relationship was not observed. In the case of both membranes, an increase in chromium concentration caused a constant, slow decrease in permeability.
PL
W pracy przeanalizowano przepuszczalność polimerowych membran nanofiltracyjnych. Badania przeprowadzono dla modelowych roztworów ścieków chromowych o pH 4, zawierających różne stężenia NaCl, Na2SO4 oraz CrCl3 . Stwierdzono, że bez względu na skład nadawy, przepuszczalność membran zależy od ich morfologii oraz właściwości elektrostatycznych. Ujemny, w warunkach procesu, ładunek membrany DL ograniczał polaryzację membrany oraz efekt osmotyczny, co korzystnie wpływało na jej przepuszczalność. W przypadku membrany HL, w warunkach procesu nie posiada ona ładunku powierzchniowego, więc nie obserwuje się efektu elektrostatycznego. Powstawanie warstwy polaryzacyjnej i efektu osmotycznego tylko w nieznacznym stopniu jest niwelowane przez efekt Donnana. Zatem w przypadku membrany HL, mimo jej otwartej struktury, obserwowano znacznie wyższy spadek przepuszczalności dla separowanych roztworów soli. W przypadku dodatnio naładowanej w warunkach procesu membrany CK występowało zwiększenie polaryzacji membrany oraz obniżenie jej przepuszczalności. Praktycznie wykluczające użycie membrany CK jako membrany nanofiltracyjnej do zatężania chromu w roztworach soli. Obecność niewielkich ilości chromu w mieszaninie zawierającej ustalone stężenie chlorków i siarczanów powodowała nieznaczny wzrost przepuszczalności membrany DL w stosunku do roztworów samych soli. W przypadku membrany HL takiej zależności nie obserwowano. W przypadku obu membran wzrost stężenia chromu powodował stały, powolny spadek przepuszczalności.
EN
The aim of this study was experimental and modelling analysis of the nanofiltration process used for the removal of chromium(III) ions from salt solution characterized by low pH. The experimental results were interpreted with Donnan and Steric Partitioning Pore (DSP) model based on the extended Nernst-Planck equation. In this model, one of the main parameters, describing retention of ions by the membrane, is pore dielectric constant. In this work, it was identified for various process pressures and feed compositions. The obtained results showed the satisfactory agreement between the experimental and modelling data. It means that the DSP model may be helpful for the monitoring of nanofiltration process applied for treatment of chromium tannery wastewater.
PL
Po przeanalizowaniu danych dotyczących szczelinowania hydraulicznego złóż gazu z łupków stwierdzono, że ze względu na zasolenie płynów powrotnych znacznie przekraczające najwyższe dopuszczalne wartości dla oczyszczonych ścieków przemysłowych, konieczne jest ich odsalanie. Przeanalizowano możliwości wykorzystania procesów membranowych do odsalania płynów powrotnych po szczelinowaniu hydraulicznym złóż gazu z łupków. Na podstawie doniesień literaturowych stwierdzono, że wykorzystanie układów procesów membranowych pozwala na odsolenia płynu powrotnego do poziomu umożliwiającego jego ponowne wykorzystanie. Jednak z punktu ekonomicznego zasadne wydaje się być stosowanie tylko układu nanofiltracja (NF) z odwróconą osmozą (RO). Ponadto niezbędne jest wstępne oczyszczanie płynu powrotnego polegające na usunięciu zawiesiny i substancji organicznych do poziomu, który umożliwi jego odsolenie w procesach NF i RO.
EN
A review, with 40 refs., of methods for desalination by reverse osmosis, nanofiltration, forward osmosis, electrodialysis and membrane distillation. The combined system of nanofiltration and reverse osmosis was recommended for practical use.
EN
Analyze of chromium(III) transport process from mixtures of Cr(III)/Cr(VI) ions with polymer inclusion membrane (PIM) system have been done. Di(2-ethylhexyl) phosphoric acid (D2EHPA) have been used as a carrier. It was found that the transport efficiency in PIM is dependent on the carrier concentration in the membrane. It was found that there is an optimal range of carrier concentration in the membrane, which ensures rapid and efficient transport. In studied system optimal D2EHPA concentration was in range between 0,9- 1,5 mol/dm3. Membrane worked as selective barrier for Cr(VI) ions. However increase of Cr(VI) concentration above 0,0005 mol/dm3 negatively influenced Cr(III) transport. It was caused by degradation of the polymer inclusion membrane made of cellulose triacetate (CTA) . Strongly oxidizing Cr(VI) ions can damage polymer inclusion membrane with CTA matrix. The chemical attack of strongly oxidant Cr(VI) ions could lead either to hydrolysis of the pendant acetyl group or to oxidation of polymer backbone leading to chain scission. Moreover, oxidation is accelerated at high concentration of Cr(VI) ions. The membrane containing D2EHPA as a carrier can be recommended for selective separation of Cr(III) ions only from diluted Cr(VI)/Cr(III) mixtures. However the polymer inclusion membrane need a change the polymer matrix.
|
|
tom Nr 4
286--287
PL
Zbadano zjawisko powstawania wody w membranie ciekłej zawierającej D2EHPA oraz CYANEX272 w roli przenośników jonów. W układzie zachodzi micelizacja cząsteczek D2EHPA, a w powstających agregatach tworzą się przestrzenie/kanały transportowe umożliwiające przepływ jonów Cr(III). CYANEX 272 nie tworzy tak rozbudowanych struktur. Opisany mechanizm transportu stanowić będzie podstawę teoretyczną do opracowania modelu matematycznego dla transportu jonów Cr(III) w badanym układzie z SLM.
EN
A phenomenon of water formation in the liquid membrane containing D2EHPA and CYANEX272 as ions carriers was investigated in the paper Micellization of the D2EHPA particles occurs in the system. Transportation spaces/channels are formed inside created aggregates allowing the flow c Cr(III) ions. CYANEX 272 does not create such large structures. This transportation mechanism should provide a theoretical basis for the mathematical model of Cr (III) transportation in the system studied.
PL
W pracy przedstawiono wyniki badań uzyskane podczas nanofiltracji modelowych roztworów ścieków garbarskich o stężeniach 500, 1000, 2000 mg Cr3+/L. Badania przeprowadzono w półtechnicznej instalacji membranowej wyposażonej w spiralny moduł nanofiltracyjny. Zbadano wpływ ciśnienia transmembranowego na objętościowy strumień pcrmeatu oraz retencję chromu(III).
EN
The paper presents results obtained during nanofiltration of model tannery wastewaters containing 500, 1000, 2000 mg Cr' /L. Experiments were carried out in a pilot membrane installation equipped with the spiral-wound nanofiltration module. An influence of trans-membrane pressure on permeate flux and retention of chromium(III) was studied.
EN
The analyze and discussion of actual condition of an assessment of CP Environmental Management System has been done. There is no CP EMS registered actually in the polish tanneries. As a main reason of that the insufficient level of awareness of CP idea's with the polish tanneries managers was adopted. This situation can be changed by the direct, systematic information action about CP idea's as well as the rules and benefits of its implementation for tanneries managers. It can be done by special PRCP Association consulting-operating groups consisting of tanneries specialists.
PL
W pracy przeanalizowano możliwość użycia membrany NF typu UL do regeneracji chromowych ścieków garbarskich. Stwierdzono, żc warunki procesu powodują niekorzystne i nieodwracalne zmiany właściwości selektywnych testowanej membrany. Ponadto niekorzystnym zmianom ulega struktura membrany. Otrzymane wyniki wskazują, żc membrana NF typu IIL nic nadaje się do regeneracji chromowych ścieków garbarskich.
EN
The possibility of the application of HL membrane to regeneration of chromium tannery wastewater was analyzed. The results showed that the process conditions caused the unfavourable and irreversible change of selective properties of tested membrane. Moreover the membrane structure submitted the disadvantageous changes. Obtained results show that the HL membrane isn't granting to regeneration of chromium tannery wastewater.
EN
On the base of questionnaires on representative group of 21 tanneries in Poland the assessment of possibilities of cleaner technology implementation has been done. The results indicated on wide possibilities for eco-technology implementation in Polish tanneries, especially in SME’s enterprises group. Different actions can be undertaken both in investment’s and non-investment’s range changes, for example, in the range of the limiting of water usage.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.