1999
|
tom Nr 5
180-184
EN
Average unit cost of pipes and valves damage repair. Repair cost according to kind damage and pipers' diameter. Cost stream index for water supply systems damage repair.
EN
Making use of the results of many year observations and in-service studies, analyses were per- formed and generalizations were made regarding the reliability of the water-pipe networks of Brzeg, Kłodzko, Oleśnica, Opole and two regions of the city of Wrocław. The contribution of reduced pressure head and reduced daily variations in the forcing pressure at the pumping stations to the rate of pipe failure was quantified. Taking into account the results of water loss analysis for the water-pipe networks under study, the effects of pipe failure were assessed. A correlation was found to occur between water loss, water pipe loading, failure rate and maximal head of the forcing pressure at the pumping station.
|
|
tom Vol. 35, nr 2
57--62
EN
Analysis of variations in daily water demand in relationship to meteorological factors, i.e. air temperature and rainfall intensity, was carried out for the city of Wroclaw and the year 2011. 60% of water pumped into the supply system was consumed by households, 22% was used for other communal purposes, while 18% constituted water utilized by the system itself as well as water loss. Studies of the relationship between water demand and meteorological factors were performed for individual months, when the number of residents was almost constant. The relationship, in numbers, between water demand and air temperature (average and maximum) as well as rainfall intensity was estimated separately for working days (including Saturdays) and non-working days (Sundays and holidays). The statistical analysis performed implies strong influence of maximum daily air temperature on daily water demand in summer months (from May until August). Water uptake in May, June and July on days with the highest maximum temperature was higher by 11.8%, 11.1% i 13.3% respectively, than on days with the lowest maximum temperature. A noticeable influence of rainfall intensity on decrease in water demand was identified on working days in June, the warmest and the driest month in the analyzed year.
PL
Przeprowadzono analizę zmian dobowego poboru wody we Wrocławiu w 2011 r. w zależności od czynników meteorologicznych, tj. temperatury powietrza i wysokości opadów atmosferycznych. Prawie 60% z ilości wody wtłoczonej do sieci wodociagowej po-brano na potrzeby gospodarstw domowych, 22% na pozostałe cele komunalne, a 18% sta-nowiła woda zużyta na potrzeby własne systemu wodno-ściekowego oraz straty wody. Badania związków między poborem wody a czynnikami meteorologicznymi przeprowadzono w poszczególnych miesiącach, kiedy liczba mieszkańców była prawie stała. Liczbowe zależności między poborem wody a temperaturą powietrza (średnią i maksymalną) i wysokością opadów atmosferycznych określono oddzielnie w dniach roboczych (z sobotami) oraz wolnych od pracy (niedziele i święta). Z dokonanej analizy statystycznej wynika, że istnieje bardzo wyraźny wpływ maksymalnej dobowej temperatury powietrza na dobowy pobór wody w miesiącach letnich (od maja do sierpnia). W dniach o największej temperaturze maksymalnej w maju, czerwcu i lipcu pobór wody był odpowiednio o 11,8%, 11,1% i 13,3% większy niż w dniach o najmniejszej temperaturze maksymalnej w tych miesiącach. Zauważalny wpływ wysokości opadów deszczu na zmniejszenie poboru wody stwierdzono w dniach roboczych w czerwcu, który był najcieplejszym i najbardziej suchym miesiącem w analizowanym roku.
|
2002
|
tom Nr 11
402-407
EN
Characteristics of exploitation conditions of tested water supply systems. Damage sensitivity of cast iron, steel and plastics conduits. Necessity of regular exploitation testing of reliability and analysis of technical and hydraulic state of the system for making optimal decisions concerning designing, exploitation and modernization of water distribution systems.
|
|
tom R. 28, nr 1
49-54
PL
Podstawą do prognozowania kosztów naprawy sieci wodociągowej jest znajomość jednostkowych kosztów naprawy różnych rodzajów uszkodzeń przewodów i armatury oraz znajomość liczby i intensywności ich uszkodzeń. Koszty naprawy można prognozować tam, gdzie jest prowadzona systematyczna i wieloletnia rejestracja oraz analiza tych parametrów, z uwzględnieniem m.in. rodzaju i wielkości elementów sieci oraz rodzaju ich uszkodzeń. Omówiona w pracy metodyka polega na określeniu zmian wartości intensywności uszkodzeń ( ) w stałych warunkach eksploatacji sieci oraz jednostkowych kosztów naprawy uszkodzeń (Kn) w czasie eksploatacji. Umożliwia to określenie wartości wskaźnika ( ) kosztów naprawy uszkodzeń, w przeliczeniu na jednostkę długości przewodów w jednostce czasu ( Kn) oraz całkowitych rocznych kosztów naprawy uszkodzeń z wyprzedzeniem 2-4 lata. W zależności od potrzeb, koszty naprawy można prognozować w odniesieniu do określonych odcinków przewodów, części lub całej sieci wodociągowej. Przykładowe obliczenia prognozowanych kosztów naprawy uszkodzeń przedstawiono dla sieci wodociągowej we Wrocławiu i w Oleśnicy. Znajomość i możliwość prognozowania kosztów naprawy przewodów wodociągowych może być przydatna w praktyce m.in. do planowania (z kilkuletnim wyprzedzeniem) środków finansowych na naprawę sieci oraz do podejmowania optymalnych decyzji w zakresie eksploatacji i modernizacji sieci wodociągowej z uwzględnieniem rachunku ekonomicznego.
EN
Predictions of the repair costs for water-pipe networks require the knowledge of two major parameters: (1) the unit repair costs for a variety of pipe and plumbing fixture damage, and (2) the failure rate. Repair costs can be reliably predicted only if these parameters have been recorded and analyzed systematically for many years, and if the records include information about the type and size of the network elements, as well as about the kind of damage. The methods presented in this paper consist in determining the variations in the value of failure rate ( ) under in-service conditions, and in the value of unit costs of damage repair (Kn) during service. With such data, it is possible to determine the value of the damage repair cost index ( ) per pipe unit length in unit time ( Kn) and the total annual cost of damage repair 2 to 4 years ahead. If the need arises, the repair cost can be predicted for a specified section of the pipeline, as well as for a certain part or the whole of the water-pipe network. Examples of relevant calculations for the prediction of damage repair cost are presented for the water-pipe networks of two Polish municipalities (Wrocław and Oleśnica). Knowing how to reliably predict the pipeline repair costs is of crucial practical importance to the planning of expenditure (several years in advance) on the repair of water-pipe networks and to an optimal decision-making about the operation and modernization of the network, with the inclusion of economic calculations.
7
Content available remote Reliability level of municipal water-pipe networks
100%
EN
Methods for assessing the required reliability level of water-supply systems (WSS) are presented. Analysis of reliability level is carried out for two municipal water-pipe networks (Brzeg and Opole) which have been investigated pre-viously. Failure indices and average duration of failure are established. Making use of these parameters, the availability factors for the two water-pipe networks are calculated and compared with the reliability level values postulated by other investigators. The furtherance of comprehensive investigations of water-supply systems, which are in service now, as well as a thorough analysis of the available literature in order to establish the desired reliability level for the WSS has taken on a sense of urgency, because the postulated values are confusing.
PL
Przedstawiono metody oceny wymaganego poziomu niezawodności systemów zaopatrzenia w wodę. Analizę poziomu niezawodności przeprowadzono na podstawie wyników otrzymanych podczas badania wieloletniej eksploatacji sieci wodociągowych w Brzegu i Opolu. Określono wskaźniki uszkodzeń i średnie czasy niesprawności przewodów wodociągowych oraz wartości wskaźników gotowości badanych sieci, które porównano z wymaganym poziomem niezawodności według różnych autorów. Wskazano na konieczność zmniejszenia uszkadzalności i czasu niesprawności sieci wodociągowych, zwłaszcza w Opolu, w celu zwiększenia poziomu niezawodności. Konieczne jest kontynuowanie wszechstronnego badania istniejących systemów wodociągowych, aby ustalić wymagany poziom niezawodności, gdyż proponowane obecnie jego wartości są bardzo zróżnicowane.
8
Content available remote History, structure and deterioration of sewerage system in Wroclaw
63%
EN
The sewerage system is a vital component of all wastewater disposal structures. The architecture of buried municipal networks differs significantly depending on the considered city, local subsurface conditions and terrain configuration. History and characterization of sewerage system in Wroclaw which is gravitational with pressure elements (pumping stations, pressure sewers) has been presented. The total length of gravitational sewers equals to ca. 1700 km, including 1300 km combined and separate sanitary sewers as well as 400 km storm water sewers under administration of Wroclaw Municipal Water and Sewerage Systems Company only since 2010. The data about amount of wastewater and recorded failures of gravitational sewers in 2006-2008 have been collated and analyzed. The amount of wastes gathering by combined and separate sanitary sewers was equal to 43-47 million m3per year, and the average indicator of sewage effluent recalculated per one citizen of Wroclaw agglomeration equaled ca. 0.178 m3 per one day. On average per one month, the number of sewers' damages was in the range 7.3-8.3, and the average failure rate per one year and one kilometer of network length (without storm water sewers) equaled 0.07.
PL
W publikacji przedstawiono zależność między podziemną eksploatacją górniczą a procesami powstawania deformacji powierzchni terenu i wstrząsów parasejsmicznych górotworu. Omówiono również metody oceny ich wpływu na środowisko i budowle inżynierskie, a także na przydatność terenów górniczych do zabudowy. Wiele miejsca poświęcono oddziaływaniu tych procesów na niezawodność (uszkadzalność) obiektów liniowych, zwłaszcza sieci wodociągowych i kanalizacyjnych, a także określono wartości parametrów charakteryzujących tę niezawodność. Zaprezentowano oryginalne metody oceny ilościowego udziału eksploatacji górniczej w uszkadzalności sieci wodociągowych i kanalizacyjnych. Zilustrowano je na przykładzie terenu Legnicko- -Głogowskiego Okręgu Miedziowego (Polkowice) i Górnośląskiego Okręgu Przemysłowego. Określono wpływ eksploatacji górniczej na straty wody na skutek przecieków z uszkodzeń sieci wodociągowych. Podano zasady projektowania niezawodnych systemów wodociągowych i grawitacyjnych systemów kanalizacyjnych na terenach występowania niecek górniczych oraz zasady projektowania rurowych przewodów wodociągowych i kanalizacyjnych, poparte przykładami obliczeniowymi. Przedstawiono wymogi dotyczące doboru materiałów rurowych, a także budowy niezawodnych przewodów wodociągowych i kanalizacyjnych na terenach występowania szkód górniczych.
EN
Underground mining operations are a major factor contributing to the occurrence of deformations on the soil surface and to the generation of paraseismic ground tremor. The impact of those operations on the natural environment, on engineering structures, as well as on the usability of mining-affected areas for land development, is described in this book and methods of assessing these influences are presented. Particular consideration is focused on the impact of mining operations on the reliability (failure frequency) of linear objects, specifically water-pipe networks and sewer systems. The values of the parameters that describe this reliability are also presented. Original methods are proposed for assessing, in quantitative terms, the contribution of mining operations to the frequency of water-pipe network and sewer system failure. They are illustrated by examples of the Legnica–Głogów Copper District (Polkowice) and the Upper Silesian Coal Basin. The impact of mining operations on water loss caused by leakage from damaged pipes has been quantified. The book also reports on the principles of designing reliable water-pipe networks and gravitational sewer systems in areas influenced by coal basins, and provides explanations of the principles behind the design of pipelines for water supply and sewage removal – illustrated with examples of calculations. Consideration is also given to the choice of appropriate materials for pipe construction and to the fundamental principles of constructing reliable water-pipe networks and sewer systems in areas affected by the occurrence of mining damage.
10
Content available remote Kształtowanie się zużycia wody w Polsce w okresie gospodarki rynkowej
63%
|
|
tom Nr 4
135-137
EN
Comparison of indexes of water consumption per unit in Poland. Relative average water consumption in selected Polish cities.
EN
Methods of defining mining damage share in water supply systems damage. Categories of land building value. Average damage value considering pipes' diameters.