Underground fires in coal mines belong to the most common hazards, the exposure to which frequently requires long term and costly rescue operations. It is mainly connected with the specific character of underground excavations which have limited volume. This makes the maximum permissible concentration of harmful gases rapidly exceeded and may also cause changes in air flow direction. The most certain way of improving a safety situation in Polish coal mining industry is taking early prevention steps. One of the prevention methods is inertisation of the atmosphere in longwall goaf. These activities rely on partial or total replacement of air or combustible atmosphere by inert gas. Thanks to them the risk of spontaneous fires hazard and gas explosion decreases. The main reason for the use of inert gases is to reduce the oxygen content to a limit which prevents further development of fire. This article presents methods for assessing inert gas to replace oxygen in the atmosphere in goaf.
PL
W kopalniach węgla kamiennego, jednym z najczęściej występujących zagrożeń, wymagających niejednokrotnie prowadzenia długotrwałych, często kosztownych, akcji ratowniczych, są pożary podziemne. Związane jest to przede wszystkim ze specyfiką podziemnych wyrobisk górniczych, których ograniczona pojemność powoduje szybkie przekroczenie dopuszczalnej granicy koncentracji gazów szkodliwych dla zdrowia, może również powodować groźne w danej sytuacji zmiany kierunków przepływu powietrza. Najpewniejszym sposobem poprawy stanu bezpieczeństwa w polskim górnictwie węgla kamiennego jest wczesna prewencja z zastosowaniem najnowszych zdobyczy techniki. Jedną z metod prewencji są działania inertyzacyjne atmosfery kopalnianej. Działania te polegają na częściowym lub całkowitym zastępowaniu powietrza lub palnej atmosfery przez obojętny gaz. Dzięki temu zmniejsza się zagrożenie powstawania ognisk pożarów endogenicznych, jak również ewentualnych wybuchów gazów. Najważniejszym celem stosowania gazów inertnych jest obniżenie zawartości tlenu do granicy uniemożliwiającej dalszy rozwój pożaru. Celem artykułu jest przedstawienie metody oceny zastąpienia tlenu gazem inertnym w atmosferze zrobów.
W artykule scharakteryzowano system klimatyzacji centralnej kopalń podziemnych. Przedstawiono przykłady instalacji chłodniczych z wykorzystaniem wysokociśnieniowego wymiennika ciepła oraz reduktora ciśnienia hydrostatycznego. Omówiono sposób regulacji i monitoringu rozpływu wody lodowej w tych instalacjach oraz scharakteryzowano zasady sterowania parametrami wody lodowej.
W artykule przybliżono sposób wytwarzania piany azotowej, będącej pianą gaśniczą. Stosowanie azotu jako gazu nośnego obniżania temperatury w otoczeniu pożaru, również może wpływać na zmniejszenie stężenia tlenu, co jest bardzo korzystnym zjawiskiem. Przedstawiono kierunki wykorzystywania pian gaśniczych w kopalniach podziemnych. Zwrócono uwagę na polskie doświadczenia w stosowaniu pian gaśniczych.
EN
The article outlines a method of generation of nitrogen foam being an extinguishing foam. The use of nitrogen as a carrier gas to reduce the temperature in the surrounding of a fire, can also affect the reduction of oxygen concentration, which is a very positive phenomenon. The paper presents the trends in the use of extinguishing foams in underground mines. Attention has been drawn to the Polish experience in the use of firefighting foams.
Stosowanie azotu w rejonach objętych zagrożeniem pożarowym bez zamykania ich tamami izolacyjnymi umożliwia wykorzystanie go w inertyzacji zrobów czynnej ściany. W artykule przedstawiono ogólne zasady inertyzacji azotem zrobów czynnej ściany zawałowej. Scharakteryzowano metody wytwarzania azotu na potrzeby inertyzacji atmosfery kopalnianej. Podano kryteria i możliwości skutecznej inertyzacji zrobów czynnej ściany eksploatacyjnej. Zwrócono uwagę na zagrożenia oraz wymagane zabezpieczenia rejonu eksploatacyjnego przy inertyzacji atmosfery w zrobach za pomocą azotu.
EN
The possibilities of using nitrogen in fire hazardous areas without sealing excavations enable a nitrogen to goaf inertisation of an operating longwall to be used. The general principles of goaf inertisation for operating longwall are presented. Methods for generating a nitrogen for mine air inertisation are discussed. The criteria and possibilities of effective inertisation of operation longwall goaf are presented as well. It is paid attention to dangers and required protection of mining area during goaf inertisation by means of nitrogen.
In Polish underground mines in which excavations are subjected to high heat load, central and group cooling systems based on indirect cooling units are implemented. Chilled water, referred to as cold water and produced in chillers, is distributed through a pipeline network to air coolers located in mining and development districts. The coolers are often moved to other locations and the pipeline network undergoes constant modification. In such a system, parameters of cold water in different branches of the pipeline network need to be controlled. The article presents the principles for controlling the cooling capacity of air coolers installed in an underground mine. Also, the authors propose automatic control of water flow rate in underground pipeline network and in particular coolers, depending on the temporary cooling load in the system. The principles of such a system, controlling cold water distribution, and the functions of its individual components are described. Finally, an example of an automatic control of water flow rate in a central cooling system currently implemented in a mine is presented.
PL
W polskich kopalniach podziemnych o dużym obciążeniu cieplnym wyrobisk stosuje się systemy klimatyzacji grupowej i centralnej, projektowane w oparciu o urządzenia chłodnicze pośredniego działania. Wytwarzana w agregatach chłodniczych woda lodowa rozprowadzana jest siecią rurociągów do chłodnic powietrza w rejonach eksploatacyjnych i przygotowawczych. Chłodnice są często przebudowywane, a sieć rurociągów ulega ciągłej zmianie. Obieg wody w sieci rurociągów wymaga ciągłej regulacji w za kresie wymaganego natężenia przepływu wody lodowej w poszczególnych odgałęzieniach sieci rurociągów. W artykule przedstawiono zasady regulacji wydajności chłodnic powietrza. Zaproponowano układ automatycznego sterowania rozpływem wody lodowej w sieci, jaką tworzą rurociągi i chłodnice powietrza, w zależności od chwilowego zapotrzebowania mocy w chłodnicach. Omówiono zasady takiej regulacji oraz funkcje, jakie muszą spełniać poszczególne elementy układu sterowania rozpływem wody lodowej. Przedstawiono przykład wdrażanego aktualnie sterowania rozpływem wody lodowej w klimatyzacji centralnej.