The article deals with the design of capacitive pressure sensor for automated measurement of intra-abdominal pressure by a non-invasive method. A capacitive pressure sensor consists of a glass tube with evaporated thin film electrodes. The capacity change is given by the level change of displaced fluid in the tube. For capacitive sensors with different inner diameter of tubes calibration curves were experimentally found. A capacitive sensor is a subpart of an automated measuring system for clinical application of intra-abdominal pressure measurement.
PL
Artykuł dotyczy budowy pojemnościowych czujników ciśnienia do automatycznego pomiaru ciśnienia wewnątrzbrzusznego metodą nieinwazyjną. Pojemnościowy czujnik cieśnienia składa się ze szklanej rurki z naparowanymi cienkowarstwowymi elektrodami. Zmiana pojemności objawia się przez zmianę poziomu przemieszczonej cieczy w rurce. Wyznaczono doświadczalnie krzywe wzorcowania dla czujników ciśnienia z różnymi średnicami wewnętrznymi rurek. Czujnik pojemnościowy jest podzespołem automatycznego układu pomiarowego w klinicznym zastosowaniu pomiaru ciśnienia wewnątrzbrzusznego.
Sprzężenia elektromagnetyczne w mikroelektronicznych układach hybrydowych zrealizowanych w technologii LTCC W opracowaniu zaprezentowano problematykę integralności sygnałów elektrycznych w strukturach MCM (Muitichip Modules) zrealizowanych w technologii LTCC (Low Temeperature Cofired Ceramic). W aspekcie ich kompatybilności elektromagnetycznej scharakteryzowano mechanizmy propagacji znormalizowanych sygnałów elektrycznych w tego typu układach. Dla wybranych, charakterystycznych konfiguracji ścieżek przewodzących, zaprezentowano wyniki obliczeń i pomiarów zakresu zmienności parametrów elementów resztkowych w układach wzajemnie równoległych ścieżek. Określono ilościowo wpływ parametrów geometrycznych układów ścieżek i elektrycznych dla znormalizowanych sygnałów zakłócających na efektywność procesu propagacji sygnałów zakłócających w tego typu strukturach. Dla wybranych konfiguracji ścieżek zaprezentowano wyniki obliczeń i pomiarów.
EN
The problem concerning with signal integrity in Muitichip Modules MCM made in LTCC (Low Temeperature Cofired Ceramic) technology have been presented in the paper. In the aspect of electromagnetic compatibility the mechanisms of propagation of standardized electric signals were characterized in such type of circuit. The results of calculations and measurements of the change interval of parasitic element parameters in mutually parallel path systems have been presented for selected characteristic configurations of conducted path systems. In terms of quantity the influence of geometrical configuration of thick-film path systems and electrical parameters for standard test signals on efficiency of process propagation of disturbing signals in this type structures has been determined. The results of calculations and measurements have been presented for the selected path configurations.
The article presents results arise during long-run cooperation between Department of Technology in Electronics at Technical University in Kosice and Department of Electronic and Communication Systems at Rzeszow University of Technology in the field of LTCC technology. It is oriented towards the analysis of piezoresistive effects in thick- film resistors on LTCC stripes, the analysis of membranes based on LTCC for applications in the area of pressure sensors. The technology of 3D.
PL
W artykule zaprezentowano wyniki długoletniej współpracy pomiędzy Katedrą Technologii Elektronicznych Technicznego Uniwersytetu w Koszycach (Słowacja) a Zakładem Systemów Elektronicznych i Telekomunikacyjnych Politechniki Rzeszowskiej w zakresie technologii LTCC. Wzajemnie uzupełniające się badania dotyczyły analizy efektów piezoelektrycznych w grubowarstwowych rezystorach linii mikropaskowych wykonanych w technologii LTCC, jak również analizy właściwości membran (również wykonywanych w w/w technologii) wykorzystywanych w czujnikach ciśnienia. Ostatnią części artykułu poswięcono wytwarzaniu modułów w technologii 3D.